ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索

検索結果を絞り込む


全文検索:全 3057 件が検索されました。(441 - 460件を表示)
カタログ
PDF[G152-E1-06] XW2K Data Sheet
.../O unit XW2K series For PLC Connection P.2 Flexibly achieve the smallest configuration by combining with common terminal blocks For PLC Connection • This product is the industry’s smallest*1 and is mountable in two ways (vertical and horizontal)*2, ...

https://www.fa.omron.co.jp/data_pdf/cat/xw2k_g152-e1_1_6_csm1118894.pdf

カタログ
PDF[-] XW2R (PLCs) Data Sheet
...2 1 37 38 4 3 21 22 20 19 19 20 22 21 3 4 38 37 1 2 40 39 Triangular mark Note: Wire the connector terminals 1:1 so that the connector terminal numbers coincide. Cable length L (m) L 4 XW2R Models for Connection to OMRON PLCs with power supply terminals e-CON Type Ordering Information Appearance I/O Points Input/Output 16 Input Model Dimension A (mm) XW2R-N16GD-C1-COM 98.5 XW2R-N32GD-C1-COM 32 186.7 XW2R-N32GD-C2-COM Ratings and Specifications Power supply terminal block: 4 A/16 poles ...

https://www.fa.omron.co.jp/data_pdf/cat/xw2r-c_m_k_ds_e_5_7_csm1020780.pdf

カタログ
PDF[G123-E1-03] XW5T Catalog
... Required The retightening that is required for screw terminal blocks is not required for Push-in Plus terminal blocks. Your work load is reduced not only when wiring, but also for inspections, delivery (shipping), and maintenance. Safety The structure provides finger protection ...

https://www.fa.omron.co.jp/data_pdf/cat/xw5t_g123-e1_2_1_csm1050325.pdf

カタログ
PDF[G124-E1-07] XW5T DIN Track Push-in Terminal Block...
... identify wiring. (Material: PA resin, blank) XW5@-P4.0-@ Note: 1. Different models are used for the top and side surfaces. 2. There is no place to mount the Top-surface Labels on Two-tier Terminal Blocks with a width of 3.5 mm, ...

https://www.fa.omron.co.jp/data_pdf/cat/xw5t_g124-e1_1_20_csm1050323.pdf

マニュアル
PDF[0674782-0B] C200HW-PA204S 電源ユニット 取扱説明書(日/英語)
... not attempt to take the unit apart and do not touch any internal parts while the power is being supplied. Doing either of these may result in electrical shock. Do not touch any of the terminals while the power is being supplied. Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/c200hw-pa204s_inst-0674782-0b.pdf

マニュアル
PDF[1167019-3A] CJ1W-AD042/DA042V アナログ入出力ユニット 取扱説明書 (...
... the AG terminals in order to use the CJ1W-AD042 under EMC compliance. Be sure to install a surge suppressor for any inductive load (such as electro-magnetic contactor, relay, or solenoid) in the system. Separate the unit from devices generating surges. Not doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/cj1w-ad042_-da042v_inst-1167019-3a.pdf

マニュアル
PDF[2102435-4B] CJ1W-ID[][]/OD[][] High Speed DIO Uni...
... of 45q C when all 32 inputs are energized. It is suitable for 55q C when 24 inputs maximum are energized. When using in a surrounding air temperature of over 45q C, maximum 24 of the input circuits shall be connected or the input circuitry shall be designed ...

https://www.fa.omron.co.jp/data_pdf/mnu/cj1w-id2___od2___(iowiringdiagram)_inst-2102435-4b.pdf

マニュアル
PDF[4029655-1A] CP1W-ADB21/-DAB21V/-MAB221 Instructio...
..., or property damage. Caution ! Indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury. Warnings and Cautions ! WARNING Do not attempt to take any Unit apart while the power is being supplied. Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/cp1w-adb21_-dab21v_-mab221(safetyprecautions)_inst-4029655-1a.pdf

マニュアル
PDF[4031560-2B] CP1W-ADB21/-DAB21V/-MAB221 取扱説明書(安全上の...
...Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury, or property damage. Caution ! Warnings and Cautions ! WARNING Do not attempt to take any Unit apart while the power is being supplied. Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/cp1w-adb21_-dab21v_-mab221(safetyprecautions)_inst-4031560-2b.pdf

マニュアル
PDFSYSMAC CS-series Programmable Controllers
... a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. Caution Operating Environment Precautions ! Warnings and Cautions ! WARNING Do not attempt to take any Unit apart while the power is being supplied. Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/cs1w-drm21-v1_-rpt01(safety precautions)_inst-0675256-4b.pdf

マニュアル
PDF[1124379-1D] CS1W-V600C1□, CJ1W-V600C1□ IDセンサユニット ...
... or death. Additionally there may be significant property damage. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. WARNING Never attempt to disassemble any Units while power is being supplied. Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/cs1w-v600c1__cj1w-v600c1__inst-1124379-1d.pdf

マニュアル
PDF[0675639-0D] CS1W-SCB□□-V1/SCU□□-V1, CJ1W-SCU□□-V1...
... with double safety mechanisms. Safety Precautions ! WARNING Fail safe measures must be taken by the customer to ensure safety in the event of incorrect, missing, or abnormal signals caused by broken signal lines, momentary power interruptions, or other causes. Not doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/cs1w_cj1w-scu_-sbc(safetyprecautions)_inst-0675639-0d.pdf

マニュアル
PDF[0675497-4D] CS1W-SCB□□-V1/SCU□□-V1, CJ1W-SCU□□-V1...
... with double safety mechanisms. Safety Precautions ! WARNING Fail safe measures must be taken by the customer to ensure safety in the event of incorrect, missing, or abnormal signals caused by broken signal lines, momentary power interruptions, or other causes. Not doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/cs1w_cj1w-scu_-sbc_(safetyprecautions)_inst-0675497-4d.pdf

マニュアル
PDF[1618379-7B] CS1W-PTS51 プロセス入力ユニット 取扱説明書(安全上のご注意)(...
... potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. Caution Operating Environment Precautions ! Warnings and Cautions ! WARNING Do not attempt to take any Unit apart while the power is being supplied. Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/csseries(cs1w-pts51)(safetyprecautions)_inst-1618379-7b.pdf

マニュアル
PDF[0675228-9B] CSシリーズ プログラマブルコントローラ 取扱説明書(安全上のご注意) (...
...Locations subject to dust (especially iron dust) or salts Locations subject to exposure to water, oil, or chemicals Locations subject to shock or vibration Caution • • • • Do not attempt to take any Unit apart while the power is being supplied. Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/csseries(safetyprecautions)_inst-0675228-9b.pdf

マニュアル
PDF[0631597-0H] DRT2, XWTシリーズ リモートI/Oターミナル 取扱説明書 (日/英...
... is being supplied. Doing either of these may result in electric shock. Make sure the connectors are lined up and push the Expansion Unit and the Basic Unit together. ・Do not attempt to disassemble, repair, or modify any Units. Any attempt to do ...

https://www.fa.omron.co.jp/data_pdf/mnu/drt2_xwtseries_inst-0631597-0h.pdf

マニュアル
PDF[9540393-4A] E2E(Q)-□-IL□ 近接センサ 取扱説明書 (日/英語)
...Control output *5 OFF Flashing Communication indicato( r Green) (1sec cycles) ON Operation indicato( r Orange) OFF NO *3 Precautions for Correct Use (1) Do not install the product in the following locations. Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/e2e(q)-_-il__inst-9540393-4a.pdf

マニュアル
PDF[5387066-4C] E2E(Q)-XB/XC(ベーシックモデル) 近接センサ 取扱説明書(日/...
...-shot function and select a timer time of 1 to 16,383ms(T). ) Blinking 15 0 IO-Link mode (COM) Orange 20 Rated sensing distance NO (1) Do not install the product in the following locations. Doing so may result in product failure or malfunction. ①Outdoor locations directly subject to sunlight, rain, snow, water droplets, or oil. ②Locations subject to atmospheres with chemical vapors, in particular solvents and acids. ③Locations subject to corrosive gases. (2) The Sensor may malfunction if used near ultrasonic cleaning equipment, high-frequency equipment, transceivers, cellular phones, inverters, or other devices that generate a high-...

https://www.fa.omron.co.jp/data_pdf/mnu/e2e(q)-xb_xc(basicmodel)_inst-5387066-4c.pdf

マニュアル
PDF[1288888-5K] E2EF-(Q)XD, E2FM-(Q)XD 近接スイッチ 取扱説明書(日...
...Iron with galvanizing ■EFFECTS OF SURROUNDING METAL ■EXTERNAL DIMENSIONS When mounting the proximity switch in a metal panel, maintain the clearances given in table 2. When installing it with the nut, the value is different depending on the kind of the nut used, ...

https://www.fa.omron.co.jp/data_pdf/mnu/e2ef-(q)xd_e2fm-(q)xd_inst-1288888-5k.pdf

マニュアル
PDF[3128471-0C] E2NC-EA0シリーズ スマートアンプ分離近接ユニット 取扱説明書(日/...
... of at least 0.3 mm2 for extension. · Do not apply the forces on the cord exceeding the following limits: Pull: 29.4N; torque: 0.1N·m; pressure: 20N; bending: 29.4N · Always keep the protective cover in place when using the product. Not doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/e2nc-ea0series_inst-3128471-0c.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。