全 610 件が検索されました。(221 - 240件を表示)
- マニュアル
... single instruction. Origin proximity input Contact 0.02 Origin input Contact 0.06 Pulse frequency Search high speed 10kHz Search acceleration ratio 2000Hz/4ms Search deceleration ratio 2000Hz/4ms Search proximity speed 1000Hz CCW ...
- マニュアル
....) Output method: Sinking or sourcing transistor outputs (The method is determined by Pulse I/O Module model.) Normal outputs Pulse outputs --- 12 max. (6 per Pulse I/O Module) 4 max. (2 per Pulse I/O Module) Output method: ...
- マニュアル
...Do not reverse the polarity of the 24-V power supply. The polarity must be correct. Otherwise, the motor may start running unexpectedly and may not stop. Caution Make sure the unit version of the Position Control Unit is 2.3 or later before using the ...
- マニュアル
...At start of operation NO 4 Search/Return Initial Speed 0 pps 0 pps At start of operation : 100,000 pps Origin Search Settings 1 Default Use define origin operation Do not use. 1-1 CW Possible settings Do not use. When setting is read by CPU Unit When power is turned ON Use. Search Direction ...
- マニュアル
... pulse output 0 in Continuous Mode at 500 Hz. When CIO 0.01 turns ON, pulse output is stopped by INI(880). i 0.00 @SPED D100 01F4 D101 0 #0000 Pulse output 0 #0100 Pulse + Direction output, CW, Continuous Mode Target frequency: 500 Hz D100 0.01 @INI #0000 Pulse output 0 #0003 Stop pulse output 0 (Not used.) CP1E/CP2E CPU Unit Instructions Reference Manual(W483) 2-329 INI z Stopping Pulse Output (P = 0000 to 0003, 0030, 0031 or 1000 hex and C = 0003 hex) 2 Instructions PRV Instruction HIGH-SPEED COUNTER PV READ Mnemonic PRV...
- マニュアル
... the origin search operation is set to mode 1 or mode 2 in the PLC Setup, PWM outputs cannot be used for the output terminals that are used for error counter reset outputs. Pulse I/O Module No. OUT00 Normal outputs ...
- マニュアル
...Input B Encoder or other pulse generators Decremental pulse Input Z Precautions for Safe Use 9-3-4 Encoder Direction Setting There are two following types for the encoder directions of an Encoder Input Slave Unit. • Forward direction at ...
- マニュアル
... and input B. If signal A leads to B, the Counter increments. If signal B leads to A, the Counter decrements. Counter Input A A Incremental encoder Input B B Input Z Z (Reset i nput) Count up (CW) Count down (CCW) Phase A Phase B 1 2 3 2 1 0 Multiplication x1 1 2 3 4 5 6 5 4 9 10 11 12 11 10 9 8 3 2 1 0 Multiplication x2 1 2 3 4 5 6 7 8 7 6 5 4 3 2 1 0 Multiplication x4 Multiplication x1 By default ...
- マニュアル
...NJ/NX-series CPU Unit Motion Control User’s Manual (W507) 9-63 9 9-6-3 Circular Interpolation 9-6-3 9-6 Multi-axes Coordinated Control Fa0 Axis A1 motion 9 Motion Control Functions Y coordinate CCW CW ...
- マニュアル
...I1 8 IOV 8-6-1 NX-PG0112 IOG B 1 IOG B I/O Name Terminal No. Sym bol I/O Name A1 A O Pulse output A (CW/PLS) B1 B O Pulse output B (CCW/DIR) A2 IOV O Pulse output, 24V B2 IOV O Pulse output, 24V A3 O0 O External output 0 B3 NC --- Not used. A4 IOV O External output, 24V B4 IOV O External output, 24V A5 NC --- Not used. B5 NC --- Not used. A6 I0 I External input 0 B6 I1 I External input 1 A7 IOV O Sensor power supply output, ...
- マニュアル
..._sAXIS_REF The corresponding variable for arm 1. _sAXIS_REF The corresponding variable for arm 2. _sAXIS_REF The corresponding variable for arm 3. _sAXIS_REF The corresponding variable for the rotary axis attached to the end effector . --- You can select ...
- マニュアル
...Setting value 16#0000 PTP (ABS) 16#0100 PTP (INC) 16#0101 Linear interpolation (ABS) 16#0200 Linear interpolation (INC) 16#0201 Circular interpolation (Border point/ABS) Circular interpolation (Border point/INC) Circular interpolation (Center/...
- マニュアル
... the circular interpolation mode, path direction, interpolation velocity, interpolation acceleration, interpolation deceleration, and combined jerk for the two axes. 9-56 NY-series Industrial Panel PC / Industrial Box PC Motion Control User's Manual (W559) 9 Motion Control Functions Y coordinate CCW ...
- マニュアル
... Values Set value 0 1 Descripition A forward direction command sets the motor rotation direction to clockwise. A forward direction command sets the motor rotation direction to counterclockwise. • The motor rotation direction when viewing the shaft from the load side is called clockwise (...
- マニュアル
... to A3 in a circular motion on a 2D plane. Either absolute or relative positioning is possible. You can specify the circular interpolation mode, path direction, interpolation velocity, interpolation acceleration, interpolation deceleration, and combined jerk for the two axes. Y coordinate CCW ...
- マニュアル
...Origin Search Settings Name 1 Use define origin operation Default Do not use. Possible settings Do not use. When setting is read by CPU Unit When power is turned ON Use. 1-1 Search Direction CW CW At start of operation CCW 1-2 Detection Method Method 0 Method 0 At start of operation Method 1 Method 2 1-3 Search Operation Inverse 1 1-4 Operation Mode Mode 0 Inverse 1 At start of operation Inverse 2 Mode 0 At start of operation Mode 1 Mode 2 1-5 Origin Input Signal NC NC At start of operation NO...
- マニュアル
...LREAL _sGROUP_REF _sAXIS_REF _sAXIS_REF _sAXIS_REF _sAXIS_REF LREAL LREAL LREAL 150 220 500 10 62.5 MC_Group000 MC_Axis000 MC_Axis001 MC_Axis002 MC_Axis003 CW 0 0 0 Category A A A A A B B B B B B B B B LREAL 0 B UINT LREAL LREAL LREAL LREAL LREAL show 80 -379 325 150 100 240 C A A A A A A Set the origin position of Robot 1 as shown below. 34 Value Once you complete setting the Delta3/Delta3R, click the Next > Button at the lower right corner...
- マニュアル
...A/H C/K DATA CHECK MD ST C/K DATA CHECK MD OVERWRITE COUNT CONTROL MD ST S/L OVERWRITE COUNT CONTROL MD S CALCULATION WRITE --- --- --- CALCULATION WRITE CW A/S ID CODE READ ID ST H ID CODE READ ID H READ WITH ERROR CORRECTION QR ST A/H --- --- --- WRITE WITH ERROR CORRECTION QW ST A/H --- --- --- V600 and V680 Command Comparison Command code Command name Communications specification Section 3 Communications Commands Communications Subcommands V680 commands Command name V600 commands Command code Data specification Command name Command code Data specification COMMAND PROCESSING TERMINATE AA --- COMMAND PROCESSING TERMINATE AA ---...
- マニュアル
... beam is stared into deliberately". Item Specification MX-Z2000H-V1 Remarks MX-Z2050H-V1 MX-Z2055H-V1 Wavelength 655 nm Visible laser Laser medium Semiconductor laser - Maximum output 1 mW - Laser oscillation type ...
- マニュアル
... beam is stared into deliberately". Item Specification MX-Z2000H-V1 Remarks MX-Z2050H-V1 MX-Z2055H-V1 Wavelength 655 nm Visible laser Laser medium Semiconductor laser - Maximum output 1 mW - Laser oscillation type ...