ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 11976 件が検索されました。(4421 - 4440件を表示)
マニュアル
PDF[P537-E1-01] ZW-CE1 Displacement Sensor (Confocal ...
... tag data links of the destination device. ■Definition of the data type to access the signals (Union) This data type is used to access the control signals and status signals. Data type name Data type U_EIPFlag UNION F BOOL[32] ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/p537-e1-01_zw-ce1.pdf

マニュアル
PDF[P541-E1-01] V750 Series RFID System CJ-series Gen...
...(4-digit hex) Description Destination device command (Read settings) Space (Options are separated by a space.) + ”typ” (product type): GETR #7970 ('yp') #2066 (' 'f') command option Space (Options are separated by a space.) + ”fwv” (firmware version): #7677 ('v'...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/p541-e1-01_v750.pdf

マニュアル
PDF[P542-E1-01] V750 Series RFID System CJ-series Gen...
...obtain the file, contact your OMRON representative. Name CX-Programmer project file (extension: cxp) CX-Programmer project file (extension: psw) File name OMRON_V750_PMCR232C_EV1 02.cxp Version Ver.1.02 OMRON_V750_PMCR_EV100.ps ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/p542-e1-01_v750.pdf

マニュアル
PDF[P543-E1-01] V750 Series RFID System NJ-series Gen...
...47 'G' 45 'E' 54 'T' 52 'R' 20 '' 74 79 70 't' 'y' ‘p’ Send command 20 '' 66 ‘f’ 20 '' 74 't' 77 ‘w’ 76 ‘v’ 0A [LF] Terminator *Receive message 1 (at normal process) 47 'G' 45 54 'E' 'T' Command ••• Product type 52 'R' 22 '”' 30 20 '' 30 30 30 ‘0000’ Response code 66 77 76 ‘f’ ‘...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/p543-e1-01_v750.pdf

マニュアル
PDF[P544-E1-01] V750 Series RFID System NJ-series Gen...
...]) ●Send/receive message *Send message 01 [SOH] Header 47 'G' 45 54 52 'E' 'T' 'R' Command 20 '' 74 't' 79 70 20 66 'y' ‘p’ ' ' ‘f’ Data (Parameter) 77 ‘w’ 76 ‘v’ 79 'y' 70 ‘p’ **** FCS 0D 0A [CR] [LF] Terminator *Receive message 1 (at normal process) 01 [SOH] Header 47 'G' 45 54 52 'E' 'T' 'R' Command **** Product type 22 '”' 30 30 30 30 ‘0000’ Response code 20 '' 20 66 77 76 '' ‘f’ ‘...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/p544-e1-01_v750.pdf

マニュアル
PDF[P558-E1-01] ZW-series Displacement Sensor NJ-seri...
...Receive buffer Receive data storage area (stores the receive buffer data) ●Send/Receive messages *Send message 56 52 V R Command 0D [CR] Terminator *Receive message (at normal process) 5A Z 57 W 56 V 65 e 32 2 30 0 2D 43 C Product type 31 1 35 5 20 [SP] Blank 20 [SP] Blank 72 r 31 2E 1 . Version 30 0 30 0 30 0 20 [SP] Blank 31 1 32 2 2F 30 32 / 0 2 Release data 2F / 30 0 39 9 0D [CR] Terminator 37 9.Program *Receive message (at error process) 45 52...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/p558-e1-01_zw-series.pdf

マニュアル
PDF[P559-E1-01] ZW-series Displacement Sensor NJ-seri...
...(stores the receive buffer data) Receive buffer 40 9. Program ●Send/Receive messages *Send message 56 52 V R Command 0D [CR] Terminator *Receive message (at normal process) 5A Z 57 W 56 V 65 e 32 2 30 0 2D 43 C Product type 31 1 35 5 20 [SP] Blank 20 [SP] Blank 72 r 31 2E 1 . Version 30 0 30 0 30 0 20 [SP] Blank 31 1 32 2 2F 30 32 / 0 2 Release data 2F / 30 0 39 9 0D [CR] Terminator *Receive message (at error process) 45 52 E R Error ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/p559-e1-01_zw-series.pdf

マニュアル
PDF[P589-E1-02] FZ5 Series Vision System NJ Series Et...
... the tag data links of Destination Device. ■Definition of the data type to access the signals (Unions) This data type is used to access the control signals and status signals. Data type name Data type U_EIPFlag UNION F BOOL[32] ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/p589-e1-02_fz5.pdf

マニュアル
PDFppmn-001k_s8ba-24d24d___lf.pdf
...ップ時間初期値の目安にしてください(バッテリの点検をする際も同様です) 。 1. 接続機器の総容量(消費電力)を、W(ワット)に統一します。 表示方法としては、A(アンペア)表示、W(ワット)表示があります。 例 1:DC24V、145W 例 2:DC24V、1.8A A と表記されてい...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/ppmn-001k_s8ba-24d24d___lf.pdf

マニュアル
PDF[Q113-E1-07] V700-CD1D-V3/CD2D-V3 Electromagnetic ...
...-V3 (RFID) Controller The V700-CD1D-V3/V700-CD2D-V3 incorporates an RS-232C interface, thus connecting to personal computers and Programmable Controllers (PCs) over RS-232C to process large amounts of data flexibly with simple commands. V700-H01 and V700-H02 (RFID) R/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/q113-e1-07_v700-cd_d-v3.pdf

マニュアル
PDF[Q134-E1-02] V530-R2000 2D Code Reader User's Manu...
...l m n z - - ! END Ins. ENT:Select Key. SECTION 6 Backing Up Data in Memory Cards 50 E F GH I J S T U VWX e f g h i j s t u v w x 4 5 6 7 8 9 ( ) ^ ` BS INS ← → Characters that can be input (A period (.) cannot be input.) SPC Inserts a space. DEL Deletes one character to the right of the cursor. BS Deletes one character to the left of the cursor. INS Switches between insert (default) and overwrite modes. ← Moves the cursor left. → Moves the cursor right. A confirmation screen ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/q134-e1-02_v530-r2000.pdf

マニュアル
PDF[Q178-E1-03] FZM1 Series Specialized Vision Sensor...
... an external device. UVWR parameter (Enabled only when the stage type is UVW or UVWR.) For details, see below. R1 to R4, θ1 to θ4 R1 to R4 are distances from the rotation center of the stage to the actuator pins of U/V/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/q178-e1-03_fzm1.pdf

マニュアル
PDF[RFM-012L] V750-BA50C04-JP/HS01□A-JP(-WP)/D13P70 リ...
...-HS01LA-JP-WP 円偏波 直線偏波 使用周波数 952~954MHz ア ン テナ利得 8.0dBi 以下 入力イ ン ピーダ ン ス 公称50Ω V.S.W.R < 1.5 : 1 最大入力電力 1W ■ ア ン テ ナケーブ ル(形V740-A01 3M/10M/20M) 項目 仕様形V740-A01 3M ケーブル損失ケーブルサイ ズ 形V740-A01 10M 約 1.5dB 3D-2V(Φ5.5mm)...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/rfm-012l-web1_v750-ba.pdf

マニュアル
PDF[RFM-015F] V750-BB50C04-JP/HS01□A-JP(-WP)/D13P70 リ...
...-HS01LA-JP-WP 円偏波 直線偏波 使用周波数 952~954MHz ア ン テナ利得 8.0dBi 以下 入力イ ン ピーダ ン ス 公称50Ω V.S.W.R < 1.5 : 1 最大入力電力 1W ■ ア ン テナケーブル(形V740-A01 3M/10M/20M) 項目 仕様形V740-A01 3M ケーブル損失ケーブルサイ ズ 形V740-A01 10M 約 1.5dB 3D-2V(Φ5.5mm)...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/rfm-015f-web1_v750-bb.pdf

マニュアル
PDF[0646113-6D] S82K スイッチングパワーサプライ 取扱説明書(日/英/伊/独/仏/西語...
... l'utiliser en toute sécurité et correctement. Garder ce manuel à portée de main lors des opérations. 0646113-6D Nomenclature Suitability for Use Safety standards EN Fig 1 1. DC output terminals (q) are galvanically separated from input terminals (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/s82k_inst-0646113-6d.pdf

マニュアル
PDF[2194145-4D] S8EA スイッチングパワーサプライ 取扱説明書 (日/英/伊/独/仏/西...
...2 4 3 -V +V Verwenden Sie das Produkt nicht, wenn eine Verschlechterung oder ein Defekt vorliegt (2) Verdrahtung 1. Führen Sie die Erdung immer vollständig aus. Es wird eine Schutzerdungsklemme verwendet, die in den Sicherheitsstandards festgelegt wurde. ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/s8ea_inst-2194145-4d.pdf

マニュアル
PDF[0191884-7F] S8EX スイッチングパワーサプライ 取扱説明書 (日/英/伊/独/仏/西...
...: 24V DC/6.3A : 48V DC/3.2A Verwenden Sie das Produkt nicht, wenn eine Verschlechterung oder ein Defekt vorliegt (2) Verdrahtung 1. Führen Sie die Erdung immer vollständig aus. Es wird eine Schutzerdungsklemme verwendet, die in den Sicherheitsstandards festgelegt wurde. ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/s8ex_inst-0191884-7f.pdf

マニュアル
PDF[1617133-0I] S8T-DCBU-01 DCバックアップブロック 取扱説明書 (日/英語)
...(約 23VDC)、バックアップ運ずにバッテリホルダのスイッチを ON または Fig.15 のS 転に切り替わります。 ■絶縁抵抗試験 を ON してください。 S8TS-06024 □の出力電圧は、出力電圧調整トリマにより 絶縁抵抗試験を実施する場合は、DC 絶縁抵抗計・ バッテ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/s8t-dcbu-01_inst-1617133-0i.pdf

マニュアル
PDF[0697228-9F] S8TS スイッチング パワーサプライ 取扱説明書 (日/英/伊/独/仏/...
...offenen Zustand): Hinweise: 1. Transistor Ausgang: Offener Sammler 30VDC max. 50mA max. Restspannung bei Ein: bis 2V Leckstrom bei Aus: bis 0.1mA 2. D i e s e F u n k t i o n ü b e r w a c h t d i e S p a n n u n g a n d e n Ausgangsklemmen der Leistungseinheit. Wenn Sie die aktuelle Spannung überprüfen wollen, dann messen Sie bitte die Spannung an der Lastseite. Einstellbereich 22 bis 28V innerhalb ± 10 % der angegebenen Ausgangsspannung Hinweise: 1. Liegt die eingestellte Ausgangsspannung bei weniger als –10% ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/s8ts_inst-0697228-9f.pdf

マニュアル
PDF[1618627-3F] S8VM(15/30/50/100/150W) スイッチング パワーサプラ...
...下で長時間使用される場合は、上記ディレーティング曲線よりさらに 80% 以下に負荷を軽減し てください / Se i modelli 150-W sono di essere usati per un periodo lungo con una tensione in ingresso di 90 VCA o più basso, riduca il carico a 80% o di meno di suddette curve riducenti le imposte / Si los modelos 150-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/s8vm(15_30_50_100_150w)_inst-1618627-3f.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。