全 7847 件が検索されました。(2621 - 2640件を表示)
- マニュアル
... VDC) Power reset Minimum : power-opening time 0.1 s Min. pulse width: 0.05 s Power consumption H3CR-A • 100 to 240 VAC/100 to 125 VDC(When at 240 VAC, 60 Hz) Relay ON: approx. 2.0 VA (1.6 W) Relay OFF: approx. 1.3 VA (1.1 ...
- マニュアル
...3 *3 ― (START) ― *1(out) *2(power) Connections D Anschlußanordnung F * 1:Voyant de sortie * 2:Voyant d'alimentation * 3:clignotant Brochage S : Start input (Always connect) Short-circuit terminals !0 and y / ...
- マニュアル
... 3 :flicker * 1 :Ausgangsanzeige * 2 :Netzanzeige * 3 :blinkend * 1 :Voyant de sortie * 2 :Voyant d'alimentation * 3 :clignotant Classement F • 24 à 48 Vc.a./12 à 48 Vc.c.(À 24 Vc.c.) Relais ON: environ 0,9 ...
- マニュアル
... for when the terminals 2 and 7 and terminals 10 and 6 are short-circuited, and include the consumption current of the input circuit.) • 100 to 240 VAC/100 to 125 VDC(When at 240 VAC, 60 Hz) Relay ON: approx. 2.5 VA (2.2 ...
- マニュアル
... internen Komponenten beschädigt. D Vorsichtsmaßnahmen zum Gebrauch des Gerätes Halten Sie bitte alle angegebenen Grenzwerte ein, wenn das Gerät unter den folgendenn Umständen oder Umweltbedingungen eingesetzt wird. Beachten Sie die Sicherheitsstandards und üblichen Installationsvorschriften. q Bei Anwendungen, die nicht im Katalog stehen. ...
- マニュアル
...% of rated supply voltage (90% to 110% at 12 VDC) Power reset Minimum : power-opening time 0.1 s Power consumption • 100 to 240 VAC/100 to 125 VDC(When at 240 VAC, 60 Hz) Relay ON: approx. 2.0 VA (1.6 ...
- マニュアル
... 110% of rated supply voltage (90% to 110% at 12 VDC) Power reset Minimum : power-opening time 0.1 s Power consumption • 100 to 240 VAC/100 to 125 VDC(When at 240 VAC, 60 Hz) ȼȼȼȼȼȼȼȼȼȼ Relay ON: approx. 2.0 VA (1.6 ...
- マニュアル
... connexion avant Model P3G-08 Back connection socket P3G-08 Rückseitige Klemmen Modèle P3G-08 Socle à connexion arriére 0.6 45 + 0 t=1∼5 0696908-3A Timing charts UK/USA t1 t2 w―u (POWER) *1 q―e t―i (OUT) y―i (OUT) ( )*2 ( )*3 D Zeitablauf F Tableaux de minutage t1:Setting time t2:Transfer time t1:Einstellezeit t2:Umschaltzeit t1:Réglage du temps t2:Temps de transition * 1 :Instantaneous output * 2 : Star operation indicator * 3 :△ Delta operation indicator * 1 :Sofortkontakten ausgerüstet * 2 : STERN-Betriebsanzeige * 3 :△ DREIECK-Betriebsanzeige Note : Only H3CR-G8EL is provided with ...
- マニュアル
... to 120 VAC (50/60 Hz) • 200 to 240 VAC (50/60 Hz) Operating voltage range 85% to 110% of rated supply voltage Power reset Minimum : power-opening time 0.5 s Power consumption • 100 to 120 VAC: approx. 6 VA (2.6 ...
- マニュアル
... to 120 VAC (50/60 Hz) • 200 to 240 VAC (50/60 Hz) Operating voltage range 85% to 110% of rated supply voltage Power reset Minimum : power-opening time 0.5 s Power consumption • 100 to 120 VAC: approx. 6 VA (2.6 ...
- マニュアル
...When the product is used under the circumstances or environment below, ensure adherence to limitations of the ratings and characteristics. Also, take countermeasures for safety precautions such as fail-safe installations. q Use under circumstances or environment which are not described in the instruction manual. ...
- マニュアル
...) • 200 to 240 VAC (50/60 Hz) • 24 VAC/VDC (50/60 Hz) • 48 VDC, • 100 to 125 VDC Operating voltage range 85% to 110% of rated supply voltage Power consumption • 100 to 120 VAC: approx. 0.23 VA (0.22 W) at 120 VAC • 200 to 240 VAC: approx. 0.35 VA (0.3 ...
- マニュアル
... 200 to 240 VAC (50/60 Hz) • 24 VAC/VDC (50/60 Hz) • 48 VDC, • 100 to 125 VDC Operating voltage range ȼȼȼȼȼȼȼȼȼȼ 85% to 110% of rated supply voltage Power consumption • 100 to 120 VAC: approx. 0.23 VA (0.22 ...
- マニュアル
...) Flush Mounting Adapter Panel I/O Functions Conformance to EN/IEC Standards 12 to 48 VDC/24 VAC, 50/60 Hz 85% to 110% of rated supply voltage (12 to 48 VDC: 90% to 110%) Approx. 5.4 VA/3.2 W at 24 VAC/12 to 48 VDC -10 to 55°C (-10 to 50°C if Timers are mounted side by side) (with no icing or condensation) -25 to 70°C (with no icing or condensation) 25% to 85% 2,000 m max. 0216.100 Approx. 115 g (main unit only) Over-voltage category Ⅲ, pollution degree 2, ...
- マニュアル
.../24 to 240 VAC, 50/60 Hz Allowable voltage fluctuation range 85% to 110% of rated supply voltage (12 to 48 VDC: 90% to 110%) Power consumption Approx. 6.5 VA at 100 to 240 VAC Approx. 5.4 VA/3.2 W at 24 VAC/12 to 48 VDC Approx. 5.6 VA/2.7 ...
- マニュアル
... at 250 VAC 50,000 operations min. for an inductive load (cosf = 0.7) of 10 A at 250 VAC 50,000 operations min. for a motor load of 1 HP at 250 VAC 50,000 operations min. for a lamp load of 100 W at 100 VAC 10,000 operations min. for a lamp load of 300 ...
- マニュアル
...85 to 110% of rated voltage (AC) Operating voltage range 85 to 120% of rated voltage (DC) Approx. 3.5 VA (AC) Approx. 2.9 VA (AC) Approx. 3.2 VA (AC) Power consumption (*1) Approx. 1.0 W (DC) Approx. 0.8 ...
- マニュアル
...Manual and be sure you sufficiently understand the information provided before attempting to use the H7BX. Keep this Instruction Sheet close at hand and use it for reference during operation. Power supply voltage/ Power consumption 12 VDC INSTRUCTION MANUAL H7BX-A(...
- マニュアル
...Manual and be sure you sufficiently understand the information provided before attempting to use the H7BX. Keep this Instruction Sheet close at hand and use it for reference during operation. Power supply voltage/ Power consumption 12 VDC INSTRUCTION MANUAL H7BX-A(...
- マニュアル
...” Models 12 (−) Function setting mode 8 3 9 10 2 1 11 Total reset 0V (-) Sensor (+) 12 VDC Function setting mode bl-h otst kypt Models other than “- W(U) ----When it is ON, the count will shift from 0 to 999999. Disable the H7AN compatible function when replacing from the H7CX, or H7CX-N. -- 1,000 The monitored value is only displayed. It cannot be set. 1,000 Unit: year The Total run time monitor value is only displayed. It cannot be set. The software version is only displayed. It cannot be set. n-o, n-...