ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 2750 件が検索されました。(2401 - 2420件を表示)
マニュアル
PDF[Z250-E1-02] ZG Series Smart Sensor (2D Profile Me...
...Use a cable with the following pin layout, 10 Personal computer side (PC/AT compatible) (Note 1) 1 2 3 4 5 Fitting section 1 6 7 Signal name NC SD (TXD) RD (RXD) RS (RTS) CS (CTS) NC NC NC SG (GND) NC FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell 8 9 Pin No. 1 2 3 4 5 6 7 8 9 Signal name NC RD (RXD) SD (TXD) NC SG (GND) NC RS (RTS) ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z250-e1-02_zg.pdf

マニュアル
PDF[Z251-E1-04] ZFX-C10 Smart Sensor (Vision Sensor w...
...9 10 Shell 4 3 7 8 5 9 Pin No. 1 2 3 4 5 6 7 8 9 Signal name FG SD RD RS CS NC NC NC GND Shell FG Note 1: Male connector ZFX-XPT2B/XPT5B/XPT15B Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDA(-) SDB(+) NC NC NC RDA(-) NC RDB(+) GND Shell FG Note 1: Male connector 168 Item ZFX-XPT2A Cable ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z251-e1-04_zfx-c10.pdf

マニュアル
PDF[Z253-E1-02] V500-R521B2/R521C2 Bar Code Reader Us...
...damage due to static electricity. Wiring diagram „ V500-R521B2 (Cable output type) Wiring color Signal name Function Brown TRIG External trigger signal Yellow OK READ OK signal Orange NG READ NG signal Blue ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z253-e1-02_v500-r521b2_r521c2.pdf

マニュアル
PDF[Z262-E1-09A] V680-HA63A/HS5[]/HS6[]/H01-V2/D1KP[]...
...Product Configuration A V680-series RFID System consists of an ID Controller, one or more Amplifiers, one or two Antennas, and Section 1 Product Configuration RF Tags. Select the models suitable for the application. „ Using Antennas with Separate Amplifiers Programmable Controller (SYSMAC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z262-e1-09a_v680.pdf

マニュアル
PDF[Z264-E1-09] ZFX-C Smart Sensor (Vision Sensor wit...
...9 10 Shell 3 7 4 8 5 9 Pin No. 1 2 3 4 5 6 7 8 9 Signal name FG SD RD RS CS NC NC NC GND Shell FG 7 Note 1: Male connector Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDA(-) SDB(+) NC NC NC RDA(-) NC RDB(+) GND Shell FG APPENDICES ZFX-XPT2B/XPT5B/XPT15B Note 1: Male connector Item ZFX-XPT2A...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z264-e1-09_zfx-c.pdf

マニュアル
PDF[Z276-E1-01A] V400-R1CF/R1CS Multi-code Reader Use...
...Wire color Pin No. Signal name Function Reader Green 1 SD Transmission data White 2 RD Received data Blue 3 RS Transmission request Signal direction Upper equipment Gray 4 CS Transmission allowed Brown 5 TRIG External trigger signal - 6 NC Not connected Black 7 S.GND 0V Red 8 VCC Power supply External External Yellow - (Note) OK READ OK output External Orange - (Note) NG READ NG output External When you make a connection cable, use the following connectors. Recommended parts for the connector Usage Manufacturer Model For cable relay Hosiden Corporation TCS8587-0170477 For panel installation Hosiden Corporation TCS1080-0120177...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z276-e1-01a_v400-r1cf_r1cs.pdf

マニュアル
PDF[Z277-E1-01] ZS-CRT Sensor Communications Unit for...
... can be used to read and set Sensor parameters and to execute measurements. 1-2 1-1 Features and System Configuration 1-1-2 Features 1 „ Communications Interface That Connects Smart Sensors with a Host, Including OMRON PLCs (such as the ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z277-e1-01_zs-crt.pdf

マニュアル
PDF[Z290-E1-05] FZ3 Series Vision Sensor User's Manua...
... System Operation Environment FZ3 User's Manual Communication 6 ● ● ● Serial (Ethernet) ● ● FZ3 User's Manual [Normal (UDP)] Normal (TCP) Normal (UDP) (Fxxx series method) PLC link (SYSMAC CS/CJ/ CP/One) PLC link (Mitsubishi) Changing the System Environment Item Setting value [Factory default] Description Specifies the communication module. Serial/Ethernet Normal/Normal (Fxxx series method): Communication is performed with external devices through Normal communication. For differences between Normal and Normal (Fxxx series method), see the following Reference. PLC Link: Communication is performed via a link area with the PLC. Parallel Standard Parallel I/O: Communication is performed via a ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z290-e1-05_fz3.pdf

マニュアル
PDF[Z293-E1-02] FZ3-UPVD Vision Sensor Software for P...
... can be used. 68 3-2-2 PLC Link Communication Settings Procedure The setting procedure for PLC link communication settings on the FZ3 side is as follows. 1. Select [System] - [Controller] - [Startup setting] in the ADJUST mode screen. 2. Set [PLC Link (SYSMAC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z293-e1-02_fz3-upvd.pdf

マニュアル
PDF[Z302-E1-03A] FQ Vision Sensor User's Manual
... as PLCs, are connected. (Setup Mode) − [Sensor settings] − [Network] − [Ethernet] 1 2 Set [Auto] to [OFF]. Set the IP address and subnet mask according to the network where the external devices, such as PLCs, are connected. Note If you connect OMRON ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z302-e1-03a_fq.pdf

マニュアル
PDF[Z314-E1-05] FQ-MS12[] Specialized Vision Sensor f...
... Unit Ethernet Unit SYSMAC CJ2 CJ2, CJ2M Supported (Built-in port only) CJ1W-EIP21, CJ1W-ETN21 SYSMAC CJ1 CJ1H, CJ1G --- CJ1W-EIP21, CJ1W-ETN21 CJ1M Supported (Built-in port only) CJ1W-EIP21, CJ1W-ETN21 SYSMAC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z314-e1-05_fq-ms12.pdf

マニュアル
PDF[Z318-E1-02B] FZ4 Series Vision Sensor User's Manu...
...Ethernet: Normal (TCP) System > Communication > Ethernet: Normal (TCP) Ethernet: Normal (TCP Client) System > Communication > Ethernet: Normal (TCP Client) Ethernet: Normal (UDP) System > Communication > Ethernet: Normal (UDP) Ethernet:PLC System > Communication > PLC Link(SYSMAC Link(SYSMAC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z318-e1-02b_fz4.pdf

マニュアル
PDF[Z322-E1-05] ZW-C1[]T Confocal Fiber Type Displace...
... UDP or TCP client is selected. c: 0 to 255, d: to 254 Set it in the form a.b.c.d. (Default: 192.168.250.100) Communications with External Devices Description 6 Item Note If you connect an external OMRON ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z322-e1-05_zw-c1_t.pdf

マニュアル
PDF[Z327-E1-01] Z5FP-MC10/MC15 LCD Seal Profile Senso...
...㪍 㪈 Pin No. Signal name Function 1 FG (GND) Protective frame ground 2 SD (TXD) Transmission data 3 RD (RXD) Reception data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Use a compatible connector. Recommended Model Manufacturer Model Plug OMRON Corporation XM2A-0901 Hood OMRON Corporation XM2S-0911 Z5FP Setup Manual 35 SECTION 3 Connecting External Devices Wiring The maximum cable length is 15 m. Standard Z5FP Signal External device Pin No. Pin No. Signal 2 * SD(TXD)...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z327-e1-01_z5fp-mc10_mc15.pdf

マニュアル
PDF[Z328-E1-01] Z5FP-MC10/MC15 LCD Seal Profile Senso...
... the same as on the PC side. Parity None (default setting) Even, Odd Stop bits 1 bit (default setting), 2 bits Delimiter CR (default setting), LF, CR + LF Flow None(default setting) The flow control is not performed. RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z328-e1-01_z5fp-mc10_mc15.pdf

マニュアル
PDF[Z332-E1-07] ZW-CE1[]T Confocal Fiber Type Displac...
... links (i.e., tags, tag sets, and connection settings). Refer to the following manuals for details on the tag data link settings that are made with the Network Configurator. • NJ-series CPU Unit Built-in EtherNet/IP Port User’s Manual (Cat. No. W506) • ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z332-e1-07_zw-ce1_t.pdf

マニュアル
PDF[Z359-E1-03] MX-Z2000G Series Fiber Laser Marker ...
...) 2 2 RD (RXD) SD (TXD) 3 3 SD (TXD) SG (GND) 7 4 ER (DTR) D-sub, 15-pin 5 SG (GND) 6 DR (DSR) 7 RS (RTS) 8 CS (CTS) Connector hood Connector hood D-sub, 15-pin D-sub, 9-pin Precautions for Correct Use Do not connect anything to those pins other than the pins No. 2, 3 or 7 on the controller side. Fiber Laser Marker MX-Z2000G series User’s Manual 8-5 8 Operation and Control by Serial Communication  RS-422A interface Cable wiring diagram Controller side Data received Data sent...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z359-e1-03_mx-z2000g.pdf

マニュアル
PDF[Z376-E1-06] MX-Z2000H series Fiber Laser Marker S...
...1 SD (TXD) 3 3 SD (TXD) SG (GND) 7 4 ER (DTR) 1 D-sub, 15-pin 5 SG (GND) 1 6 DR (DSR) 1 7 RS (RTS) 8 CS (CTS) Connector hood D-sub, 15-pin D-sub, 9-pin Precautions for Correct Use Do not connect anything to those pins other than the pins No. 2, 3 or 7 on the controller side.  RS-422A interface Cable wiring diagram Controller side Data received Data sent External device side SDB RDB (+) 9 − SDB SDA RDA (−) 10 − SDA RDB RDA (+) 11 − RDB RDA RDB (−) 12 − RDA SG (GND)...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z376-e1-06_mx-z2000h.pdf

マニュアル
PDF[Z377-E1-06] MX-Z2000H series Fiber Laser Marker U...
...) 2 2 RD (RXD) SD (TXD) 3 3 SD (TXD) SG (GND) 7 4 ER (DTR) D-sub, 15-pin 5 SG (GND) 6 DR (DSR) 7 RS (RTS) 8 CS (CTS) Connector hood Connector hood D-sub, 15-pin D-sub, 9-pin Precautions for Correct Use Do not connect anything to those pins other than the pins No. 2, 3 or 7 on the controller side. Fiber Laser Marker MX-Z2000H series User’s Manual (Z377) 8-5 8 Operation and Control by Serial Communication  RS-422A interface Cable wiring diagram Controller side Data received Data ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z377-e1-06_mx-z2000h.pdf

マニュアル
PDF[7452518-5C] Z3R-HC12/HS12/FC12(12V仕様) 光RS-232Cリン...
...います。 100K は 1Km の こ と です。 AC アダプタ : Z3P-AC / 電源プラグコード Z3P-DC ④ ② ■仕様電源電圧 ② SD 2 RD 3 RS 4 CS 5 ER 20 DR 6 SG 7 +12V 9 ③ ⑤ ① POWER LED (緑) 形 Z3R の電源を供給する と 点灯 し ます。 ② RUN LED (緑) 相手側の形 Z3R に電源が供給 さ れ、 両者の間に光ファイバが 正 し く ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z3r-hc12_-hs12_-fc12_inst-7452518-5c.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。