全 2711 件が検索されました。(2401 - 2420件を表示)
- マニュアル
...,600 bps (Use initial setting.) Data length 8 bits (Use initial setting.) Parity Even L3 Stop bits 1 bit (Use initial setting.) Header None (Use initial setting.) Footer CR (Use initial setting.) RS/CS...
- マニュアル
... Hand-held Reader Writer 4 --- --- --- 5 Signal ground SG --- Data set ready DS Hand-held Reader Writer to host device 7 Request send RS Loops inside connector 8 Enable send CS 9 --- --- 3 9 Code (See note.) Receive data 2 6 6 --- Note: The names of signals at the host device are abbreviated with codes. Note: For conversion to a 25-pin connector, the SGC-X9P/25P-2 manufactured by Sunhayato, or an equivalent, is recommended. 36 Pin No. RFID System User's Manual Section 2 Communications Preparations •Connection with the Host Device Use the following procedure to connect ...
- マニュアル
... common retrace line SG No No 5 Send data SD No Yes 3 Receive data RD Yes No 2 Request to send RS No Yes 7 Clear to send CS Yes No 8 Connector Pin Arrangement When Viewed from the Controller ID Controller Host device Shield (Shielded wire) Note 1. Ground the shielded wire on either the Controller side or the host device side to prevent operation errors. Note 2. Internally short-circuit pins 7 (RS) and 8 (...
- マニュアル
... a cordless connector (E3X-CN02). Device Net Optical Communication PLC 16 E3X-DRT21-S User’s Manual Section 1 Features and System Configuration Features Section 1 Overview ■ This unit enables a communication interface between OMRON's PLCs (...
- マニュアル
... compatible D-sub, 9-pin Name Pin No. Name - 1 SD RD 2 RD SD 3 SG ER 4 +5 V SG 5 DR 6 RS 7 CS 8 - 9 Shield wire Connector cover 0V +5 V (View of mating section) 20 V400-H111/211 User’s Manual user_en.book Page 21 Tuesday, April 17, 2007 11:35 AM Section 2 Installation and Connections Connecting a Personal Computer (V400-W22-2M/5M Cable) Section 2 Cable • Connector The connector used for V400-W22-2M and V400-W22-5M cables is a D-sub 9-pin connector (female). The ...
- マニュアル
...1 --- --- --- 2 RD Receive Data IN 3 SD Send Data 4 --- --- --- 5 SG Signal Ground --- 6 --- --- --- 7 RS Request to Send 8 CS Clear to Send IN 9 --- --- --- OUT OUT UHF RFID System User's Manual 21 SECTION 2 Specifications and Performance (3) Ethernet Interface This port is used to connect the host to the reader via Ethernet. To connect them, use the commercial cable 10/10Base-T. Connector: RJ-45 (8 pin) LINK LED LED: Link (green) /Act (orange) ACT LED SECTION 2 Reader Pin No. Name Function I/O 1 TXD(+) Transmit Data + OUT 2 TXD(-) Transmit ...
- マニュアル
...viation Input Output Pin No. Signal name • Pin Arrangement 5 SG --- --- 2 SD --- ❍ Send data 3 RD ❍ --- Receive data 4 RS --- ❍ Request to send 5 CS ❍ --- Can send 1 9 Section 2 Wiring 9 Signal ground or common return line 6 (The example at the left is for connecting a shielded cable to the host device.) ■ Connecting to the Host Device ■ Connection Example to OMRON PLC Host device ID Controller GR GR SG SG RD SD SD RD RS RS Model Manufacturer ...
- マニュアル
...Signal name 3 7 4 8 5 9 Signal name NC SD(TXD) 2 2 SD(TXD) RD(RXD) 3 3 RD(RXD) RS(RTS) 4 4 RS(RTS) CS(CTS) 5 5 CS(CTS) NC 6 6 NC NC 7 7 NC NC 8 8 NC SG(GND) NC 9 9 SG(GND) 10 Note 1: A plug type connector is used for the PLC side. ZFV-C User’s Manual 105 Section 5 Setting USB/RS-232C Communication Specifications ● RS-232C cable for connecting a personal computer • ZS-XRS2 (cable length: 2 m) Amplifier unit side PC side (...
- マニュアル
...Example 1:1 Connection Using the RS-232C Port ■ Connection to a Windows Computer Windows computer S8M Pin Name Name Pin 1 CD 2 RD 3 SD RS4 ER 232C 5 SG inter6 DR face 7 RS 8 CS 9 CI D-Sub 9-pin (female) RS-232C SD 1 terminals RD 2 SG 3 D-Sub 9-pin (male) Example 1:1 Connection Using K3SC Serial Adapters The K3SC Serial Adapters are required when the distance is over 15 m. Computer RS232C interface CD RD SD ER SG DR RS ...
- マニュアル
...-pin Name Pin No. Name - 1 SD RD 2 RD SD 3 +24V ER 4 GND SG 5 TRIG DR 6 RESET RS 7 RUN CS 8 OK/NG - 9 ERROR Shield wire Connector cover BUSY +24 V (Brown) 0 V (Blue) Not used with RS-232C communication. TRIG (Pink) RESET (Orange) RUN (Green) OK/NG (Black) ERROR (Gray) BUSY (Yellow) (View of mating section) 60 V400-F050/250/350 User’s Manual Section 5 Communicating with PC and Programmable Controller Programmable Controller A D-SUB 9-pin connector (male) is used for the cable type V400-W23 (NPN ...
- マニュアル
...Use a cable with the following pin layout, 10 Personal computer side (PC/AT compatible) (Note 1) 1 2 3 4 5 Fitting section 1 6 7 Signal name NC SD (TXD) RD (RXD) RS (RTS) CS (CTS) NC NC NC SG (GND) NC FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell 8 9 Pin No. 1 2 3 4 5 6 7 8 9 Signal name NC RD (RXD) SD (TXD) NC SG (GND) NC RS (RTS) ...
- マニュアル
...9 10 Shell 4 3 7 8 5 9 Pin No. 1 2 3 4 5 6 7 8 9 Signal name FG SD RD RS CS NC NC NC GND Shell FG Note 1: Male connector ZFX-XPT2B/XPT5B/XPT15B Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDA(-) SDB(+) NC NC NC RDA(-) NC RDB(+) GND Shell FG Note 1: Male connector 168 Item ZFX-XPT2A Cable ...
- マニュアル
...damage due to static electricity. Wiring diagram V500-R521B2 (Cable output type) Wiring color Signal name Function Brown TRIG External trigger signal Yellow OK READ OK signal Orange NG READ NG signal Blue ...
- マニュアル
...Product Configuration A V680-series RFID System consists of an ID Controller, one or more Amplifiers, one or two Antennas, and Section 1 Product Configuration RF Tags. Select the models suitable for the application. Using Antennas with Separate Amplifiers Programmable Controller (SYSMAC ...
- マニュアル
...9 10 Shell 3 7 4 8 5 9 Pin No. 1 2 3 4 5 6 7 8 9 Signal name FG SD RD RS CS NC NC NC GND Shell FG 7 Note 1: Male connector Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDA(-) SDB(+) NC NC NC RDA(-) NC RDB(+) GND Shell FG APPENDICES ZFX-XPT2B/XPT5B/XPT15B Note 1: Male connector Item ZFX-XPT2A...
- マニュアル
...Wire color Pin No. Signal name Function Reader Green 1 SD Transmission data White 2 RD Received data Blue 3 RS Transmission request Signal direction Upper equipment Gray 4 CS Transmission allowed Brown 5 TRIG External trigger signal - 6 NC Not connected Black 7 S.GND 0V Red 8 VCC Power supply External External Yellow - (Note) OK READ OK output External Orange - (Note) NG READ NG output External When you make a connection cable, use the following connectors. Recommended parts for the connector Usage Manufacturer Model For cable relay Hosiden Corporation TCS8587-0170477 For panel installation Hosiden Corporation TCS1080-0120177...
- マニュアル
... can be used to read and set Sensor parameters and to execute measurements. 1-2 1-1 Features and System Configuration 1-1-2 Features 1 Communications Interface That Connects Smart Sensors with a Host, Including OMRON PLCs (such as the ...
- マニュアル
... System Operation Environment FZ3 User's Manual Communication 6 ● ● ● Serial (Ethernet) ● ● FZ3 User's Manual [Normal (UDP)] Normal (TCP) Normal (UDP) (Fxxx series method) PLC link (SYSMAC CS/CJ/ CP/One) PLC link (Mitsubishi) Changing the System Environment Item Setting value [Factory default] Description Specifies the communication module. Serial/Ethernet Normal/Normal (Fxxx series method): Communication is performed with external devices through Normal communication. For differences between Normal and Normal (Fxxx series method), see the following Reference. PLC Link: Communication is performed via a link area with the PLC. Parallel Standard Parallel I/O: Communication is performed via a ...
- マニュアル
... can be used. 68 3-2-2 PLC Link Communication Settings Procedure The setting procedure for PLC link communication settings on the FZ3 side is as follows. 1. Select [System] - [Controller] - [Startup setting] in the ADJUST mode screen. 2. Set [PLC Link (SYSMAC ...
- マニュアル
... as PLCs, are connected. (Setup Mode) − [Sensor settings] − [Network] − [Ethernet] 1 2 Set [Auto] to [OFF]. Set the IP address and subnet mask according to the network where the external devices, such as PLCs, are connected. Note If you connect OMRON ...