全 2685 件が検索されました。(2341 - 2360件を表示)

  • マニュアル

    ... Unit 25 13 14 1 Signal name Name 1 FG (GND) Frame ground 2 SD (TXD) Send data 3 RD (RXD) Receive data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 DR (DSR) Data set ready 7 SG (GND) Signal ground 20 ER (DTR) Data terminal ready Connect the F300-VR as shown below. SD (TXD) 2 2 SD (TXD) RD (RXD) 3 3 RD (RXD) RS (RTS) 4 4 RS (RTS) ...

  • マニュアル

    .... D. Delimiter Sets the delimiter. CR: CR only used. LF: LF only used. CR + LF: CR and LF used. F. Flow control Sets the handshake method. None: No handshaking. Xon/off: Executed by software. RS/CS: Executed using RS and ...

  • マニュアル

    ...Pin no. 25 13 14 1 Symbol Name 1 FG (GND) Frame Ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 DR (DSR) Data Settings Ready 7 SG (GND) Signal Ground 8 CD (DCD) Data Carrier Detected 20 ER (DTR) Data Terminal Ready 41 Section 2-5 Connecting Peripheral Devices Wiring Standard 25-pin Cable Connection 9-pin Cable Connection F300-E RS-232C Device RS-232C Device F300-E Symbol Pin no. Pin no. Symbol Symbol Pin no. SD (TXD) 2 2 SD (TXD)...

  • マニュアル

    ...XM2A-2501 25 13 14 1 Symbol Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 DR (DSR) Data Settings Ready 7 SG (GND) Signal ground 20 ER (DTR) Data Terminal Ready 25 Section 2-4 Connecting Power Supply Unit I/O Terminals Use only shielded RS-232C cable. Wiring Standard 25-pin Cable Connection (F309-VR) F300-E2 9-pin Cable Connection RS-232C Device RS-232C Device F300-E2 Symbol Pin no. Pin no. Symbol Symbol Pin no....

  • マニュアル

    ...Sending data SD Host device → Hand-held Reader Writer 4 --- --- --- 5 Signal ground SG --- 6 Data set enable DS 7 8 9 Request sending Clear to send --- RS CS --- Host device ← Hand-held Reader Writer Repeat p in the connector section. --- --- Transmission Specifications Transmission with the currently available V600-series Data Carriers is possible. 2-6-1 Transmission Distances Data Carrier Note Transmission distances V600-D23P53 0 to 2.5 mm V600-D23P54 0 to 4 mm V600-D23P61 0 to 11 mm V600-D23P66 0 to 17 mm (see note 2) V600-D23P66SP 0 to 12 mm V600-D23P71...

  • マニュアル

    ... pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 30 Model No. Plug XM2A-0901 Hood XM2S-0911 Section 4-3 Wiring 4-3 Wiring Use only shielded RS-232C cable. Standard Connections F150 Signal name External device Pin Pin Signal ...

  • マニュアル

    ...2-1 Amplifiers 2-1-1 Names and Functions of Components Component Names DeviceNet (CompoBus/D) Connector For connecting to DeviceNet. Data Indicators Green: Read data displayed in bit units. Red: Flashes to show error classification (bits 0 to 7 only). ...

  • マニュアル

    ... pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 4-2 Model No. Plug XM2A-0901 Hood XM2S-0911 Wiring Use only shielded RS-232C cable. Standard Connections F400 Signal name External device Pin Pin * * * * * Shield 20 Signal name Section Connection...

  • マニュアル

    ... pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 32 Model No. Plug XM2A-0901 Hood XM2S-0911 Section 4-3 Wiring 4-3 Wiring Use only shielded RS-232C cable. Standard Connections F150 Signal name External device Pin Pin Signal ...

  • マニュアル

    ... Run mode, will continue until all of the data has been output, even if the mode is changed. Data output will not be interrupted. 2. A timeout error will occur if there is no response from the computer within the set time when RS/...

  • マニュアル

    ... and measurement results can be output. Measurement Commands I/O via the RS-232C Port F400 Computer Input command Perform measurement *The BUSY terminal turns ON while a measurements are being performed. Output result Receive result Note When RS/...

  • マニュアル

    ...-0911 Pin 38 Model No. Plug Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Section 4-1 Specifications 4-1-2 Wiring Only use a shielded RS-232C cable. Standard Connections V530-R150 Signal External device Pin Pin Signal Shield Connections for RS/...

  • マニュアル

    ...-0911 Pin 38 Model No. Plug Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Section 4-1 Specifications 4-1-2 Wiring Only use a shielded RS-232C cable. Standard Connections V530-R150 Signal External device Pin Pin Signal Shield Connections for RS/...

  • マニュアル

    ... pin numbers and names are shown below. Pin 1 Signal FG (GND) Name Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 36 Model No. Plug XM2A-0901 Hood XM2S-0911 Z141-E1-03.book Page 37 Monday, July 24, 2006 5:16 PM Section 4-2 Wiring 4-2 Wiring Use only shielded ...

  • マニュアル

    .... Data output will not be interrupted. Measurement Commands I/O via RS-232C Port F150 Computer Input command Perform measurement *The BUSY terminal turns ON while a measurements are being performed. Output result Receive result Note When RC/...

  • マニュアル

    ... for RS-232C or RS-422 RS-232C Wiring F160 External device Signal Pin SD 2 SD RD 3 RD GND 9 GND Pin Use only shielded cable. 36 Signal RS/CS control cannot be used. Section 4-2 Connecting through the Serial Interface RS-422 Wiring F160 Signal External device Pin Pin Signal RDB 5 RDB RDA 6 RDA SDB 7 SDB SDA 8 SDA GND 9 GND Use only shielded cable. Note Pin numbers on the external device will depend on the device being connected. Refer to the manual for the personal computer or PLC being connected....

  • マニュアル

    ...Pin No. Ground for maintenance or ground GR — — Shield Ground for signal or common return SG — — 5 Send data SD — Receive data RD Request to send RS Clear to send CS 3 — — 2 7 — 8 Controller Pin Layout (TOP VIEW) Note 1: To prevent an operation error, ground the shielded wire either at the controller side or the computer side mentioned above. (The figure above shows an example of grounding the shielded wire at the ID controller side.) Note 2: Short-circuit pin No. 7 (RS) and pin No. 8 (...

  • マニュアル

    ...) Plug (Female) 1 2 RD (Receiving) TX (Sending) 3 SD (Sending) RX (Receiving) SG (Signal ground) SG (Signal ground) 4 View from connecting side 5 6 7 RS (Request to send) 8 CS (Clear to send) 9 5-6 Loop back (Short-circuit) 5-2 Wiring the Host (2) Using RS-232C Connecting Cable to Extend a Cable and Connecting to IBM PC/AT or Compatible (Typical) To connect an IBM PC/AT or compatible (typical) extending a RS-232C Connecting Cable, prepare the cables as shown below. The wires in the cable must be AWG26 or thicker. Cable ...

  • マニュアル

    ...-0901 Hood XM2S-0911 Pin 16 Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Section 3-1 RS-232C Specifications 3-1-2 Wiring Only use a shielded RS-232C cable. Standard Connections V530-C300E Signal External device Pin Pin Signal Shield Connections for RS/...

  • マニュアル