PDF[Z214-E1-01B] V700-L11/L21/HMD13[]/HMD11-1/D23P41 ...
... data RD Input 3 Send data SD Output 4 − 5 Signal ground 6 − 7 8 − Output SG − − Input Request send RS Output Clear to send (CS) Input 9 Comment Normally OFF Leave this pin OPEN. Normally OPEN during service Not functioning Unused 2.1 CIDRW controller: Model V700-L21 Character format (E4 SECS I, fixed) Section 2 Communication standard ■ Cable connection example Connect the upstream controller to the CIDRW controller using the cable whose configuration is specified below. Limit the whole cable length to 15 m. Symbol DOS/V PC D-SUB...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z214-e1-01b_v700-l21_l11_hmd1___d23p41.pdf

マニュアル
PDF[Z217-E1-01] V700-L12 ID Link Unit User's Manual
...,600 bps (Use initial setting.) Data length 8 bits (Use initial setting.) Parity Even L3 Stop bits 1 bit (Use initial setting.) Header None (Use initial setting.) Footer CR (Use initial setting.) RS/CS...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z217-e1-01_v700-l12.pdf

マニュアル
PDFz219-e1-05_v600-chud_ch1d-v2_ch1d-psi.pdf
... Hand-held Reader Writer 4 --- --- --- 5 Signal ground SG --- Data set ready DS Hand-held Reader Writer to host device 7 Request send RS Loops inside connector 8 Enable send CS 9 --- --- 3 9 Code (See note.) Receive data 2 6 6 --- Note: The names of signals at the host device are abbreviated with codes. Note: For conversion to a 25-pin connector, the SGC-X9P/25P-2 manufactured by Sunhayato, or an equivalent, is recommended. 36 Pin No. RFID System User's Manual Section 2 Communications Preparations •Connection with the Host Device Use the following procedure to connect ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z219-e1-05_v600-chud_ch1d-v2_ch1d-psi.pdf

マニュアル
PDF[Z221-E1-01] V680-CA1D/CA2D/H01/D1KP58HT Heat-resi...
... common retrace line SG No No 5 Send data SD No Yes 3 Receive data RD Yes No 2 Request to send RS No Yes 7 Clear to send CS Yes No 8 Connector Pin Arrangement When Viewed from the Controller ID Controller Host device Shield (Shielded wire) Note 1. Ground the shielded wire on either the Controller side or the host device side to prevent operation errors. Note 2. Internally short-circuit pins 7 (RS) and 8 (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z221-e1-01_v680-ca_d_h01_d1kp58ht.pdf

マニュアル
PDFz223-e1-03_e3x-drt21-s.pdf
... a cordless connector (E3X-CN02). Device Net Optical Communication PLC 16 E3X-DRT21-S User’s Manual Section 1 Features and System Configuration Features Section 1 Overview ■ This unit enables a communication interface between OMRON's PLCs (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z223-e1-03_e3x-drt21-s.pdf

マニュアル
PDF[Z228-E1-03] V400-H111/H211 Handheld 2D Code Reade...
... compatible D-sub, 9-pin Name Pin No. Name - 1 SD RD 2 RD SD 3 SG ER 4 +5 V SG 5 DR 6 RS 7 CS 8 - 9 Shield wire Connector cover 0V +5 V (View of mating section) 20 V400-H111/211 User’s Manual user_en.book Page 21 Tuesday, April 17, 2007 11:35 AM Section 2 Installation and Connections Connecting a Personal Computer (V400-W22-2M/5M Cable) Section 2 Cable • Connector The connector used for V400-W22-2M and V400-W22-5M cables is a D-sub 9-pin connector (female). The ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z228-e1-03_v400-h111_h211.pdf

マニュアル
PDF[Z235-E1-02] V750-BA50C04-US, V740-HS01CA/HS01LA R...
...1 --- --- --- 2 RD Receive Data IN 3 SD Send Data 4 --- --- --- 5 SG Signal Ground --- 6 --- --- --- 7 RS Request to Send 8 CS Clear to Send IN 9 --- --- --- OUT OUT UHF RFID System User's Manual 21 SECTION 2 Specifications and Performance (3) Ethernet Interface This port is used to connect the host to the reader via Ethernet. To connect them, use the commercial cable 10/10Base-T.  Connector: RJ-45 (8 pin) LINK LED LED: Link (green) /Act (orange) ACT LED SECTION 2 Reader Pin No. Name Function I/O 1 TXD(+) Transmit Data + OUT 2 TXD(-) Transmit ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z235-e1-02_v750-ba50c04-us.pdf

マニュアル
PDF[Z240-E1-05] ZFV-C Smart Sensors (with Ultra-High-...
...Signal name 3 7 4 8 5 9 Signal name NC SD(TXD) 2 2 SD(TXD) RD(RXD) 3 3 RD(RXD) RS(RTS) 4 4 RS(RTS) CS(CTS) 5 5 CS(CTS) NC 6 6 NC NC 7 7 NC NC 8 8 NC SG(GND) NC 9 9 SG(GND) 10 Note 1: A plug type connector is used for the PLC side. ZFV-C User’s Manual 105 Section 5 Setting USB/RS-232C Communication Specifications ● RS-232C cable for connecting a personal computer • ZS-XRS2 (cable length: 2 m) Amplifier unit side PC side (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z240-e1-05_zfv-c.pdf

マニュアル
PDF[Z242-E1-04] V400-F050/F250/F350 2D Code Reader Us...
...-pin Name Pin No. Name - 1 SD RD 2 RD SD 3 +24V ER 4 GND SG 5 TRIG DR 6 RESET RS 7 RUN CS 8 OK/NG - 9 ERROR Shield wire Connector cover BUSY +24 V (Brown) 0 V (Blue) Not used with RS-232C communication. TRIG (Pink) RESET (Orange) RUN (Green) OK/NG (Black) ERROR (Gray) BUSY (Yellow) (View of mating section) 60 V400-F050/250/350 User’s Manual Section 5 Communicating with PC and Programmable Controller Programmable Controller A D-SUB 9-pin connector (male) is used for the cable type V400-W23 (NPN ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z242-e1-04_v400-f050_f250_f350.pdf

マニュアル
PDF[Z250-E1-02] ZG Series Smart Sensor (2D Profile Me...
...Use a cable with the following pin layout, 10 Personal computer side (PC/AT compatible) (Note 1) 1 2 3 4 5 Fitting section 1 6 7 Signal name NC SD (TXD) RD (RXD) RS (RTS) CS (CTS) NC NC NC SG (GND) NC FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell 8 9 Pin No. 1 2 3 4 5 6 7 8 9 Signal name NC RD (RXD) SD (TXD) NC SG (GND) NC RS (RTS) ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z250-e1-02_zg.pdf

マニュアル
PDF[Z251-E1-04] ZFX-C10 Smart Sensor (Vision Sensor w...
...9 10 Shell 4 3 7 8 5 9 Pin No. 1 2 3 4 5 6 7 8 9 Signal name FG SD RD RS CS NC NC NC GND Shell FG Note 1: Male connector ZFX-XPT2B/XPT5B/XPT15B Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDA(-) SDB(+) NC NC NC RDA(-) NC RDB(+) GND Shell FG Note 1: Male connector 168 Item ZFX-XPT2A Cable ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z251-e1-04_zfx-c10.pdf

マニュアル
PDF[Z253-E1-02] V500-R521B2/R521C2 Bar Code Reader Us...
...damage due to static electricity. Wiring diagram „ V500-R521B2 (Cable output type) Wiring color Signal name Function Brown TRIG External trigger signal Yellow OK READ OK signal Orange NG READ NG signal Blue ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z253-e1-02_v500-r521b2_r521c2.pdf

マニュアル
PDFz262-e1-10_v680.pdf
...Product Configuration A V680-series RFID System consists of an ID Controller, one or more Amplifiers, one or two Antennas, and Section 1 Product Configuration RF Tags. Select the models suitable for the application.  Using Antennas with Separate Amplifiers Programmable Controller (SYSMAC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z262-e1-10_v680.pdf

マニュアル
PDF[Z264-E1-09] ZFX-C Smart Sensor (Vision Sensor wit...
...9 10 Shell 3 7 4 8 5 9 Pin No. 1 2 3 4 5 6 7 8 9 Signal name FG SD RD RS CS NC NC NC GND Shell FG 7 Note 1: Male connector Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDA(-) SDB(+) NC NC NC RDA(-) NC RDB(+) GND Shell FG APPENDICES ZFX-XPT2B/XPT5B/XPT15B Note 1: Male connector Item ZFX-XPT2A...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z264-e1-09_zfx-c.pdf

マニュアル
PDF[Z276-E1-01A] V400-R1CF/R1CS Multi-code Reader Use...
...Wire color Pin No. Signal name Function Reader Green 1 SD Transmission data White 2 RD Received data Blue 3 RS Transmission request Signal direction Upper equipment Gray 4 CS Transmission allowed Brown 5 TRIG External trigger signal - 6 NC Not connected Black 7 S.GND 0V Red 8 VCC Power supply External External Yellow - (Note) OK READ OK output External Orange - (Note) NG READ NG output External When you make a connection cable, use the following connectors. Recommended parts for the connector Usage Manufacturer Model For cable relay Hosiden Corporation TCS8587-0170477 For panel installation Hosiden Corporation TCS1080-0120177...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z276-e1-01a_v400-r1cf_r1cs.pdf

マニュアル
PDF[Z277-E1-01] ZS-CRT Sensor Communications Unit for...
... can be used to read and set Sensor parameters and to execute measurements. 1-2 1-1 Features and System Configuration 1-1-2 Features 1 „ Communications Interface That Connects Smart Sensors with a Host, Including OMRON PLCs (such as the ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z277-e1-01_zs-crt.pdf

マニュアル
PDF[Z290-E1-05] FZ3 Series Vision Sensor User's Manua...
... System Operation Environment FZ3 User's Manual Communication 6 ● ● ● Serial (Ethernet) ● ● FZ3 User's Manual [Normal (UDP)] Normal (TCP) Normal (UDP) (Fxxx series method) PLC link (SYSMAC CS/CJ/ CP/One) PLC link (Mitsubishi) Changing the System Environment Item Setting value [Factory default] Description Specifies the communication module. Serial/Ethernet Normal/Normal (Fxxx series method): Communication is performed with external devices through Normal communication. For differences between Normal and Normal (Fxxx series method), see the following Reference. PLC Link: Communication is performed via a link area with the PLC. Parallel Standard Parallel I/O: Communication is performed via a ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z290-e1-05_fz3.pdf

マニュアル
PDF[Z293-E1-02] FZ3-UPVD Vision Sensor Software for P...
... can be used. 68 3-2-2 PLC Link Communication Settings Procedure The setting procedure for PLC link communication settings on the FZ3 side is as follows. 1. Select [System] - [Controller] - [Startup setting] in the ADJUST mode screen. 2. Set [PLC Link (SYSMAC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z293-e1-02_fz3-upvd.pdf

マニュアル
PDF[Z302-E1-03A] FQ Vision Sensor User's Manual
... as PLCs, are connected. (Setup Mode) − [Sensor settings] − [Network] − [Ethernet] 1 2 Set [Auto] to [OFF]. Set the IP address and subnet mask according to the network where the external devices, such as PLCs, are connected. Note If you connect OMRON ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z302-e1-03a_fq.pdf

マニュアル
PDF[Z314-E1-05] FQ-MS12[] Specialized Vision Sensor f...
... Unit Ethernet Unit SYSMAC CJ2 CJ2, CJ2M Supported (Built-in port only) CJ1W-EIP21, CJ1W-ETN21 SYSMAC CJ1 CJ1H, CJ1G --- CJ1W-EIP21, CJ1W-ETN21 CJ1M Supported (Built-in port only) CJ1W-EIP21, CJ1W-ETN21 SYSMAC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z314-e1-05_fq-ms12.pdf