ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 2899 件が検索されました。(2441 - 2460件を表示)
マニュアル
PDF[Z104-E1-01] F200 Visual Inspection System Operati...
...Pin no. 25 13 14 1 Symbol Name 1 FG (GND) Frame Ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 DR (DSR) Data Settings Ready 7 SG (GND) Signal Ground 8 CD (DCD) Data Carrier Detected 20 ER (DTR) Data Terminal Ready 41 Section 2-5 Connecting Peripheral Devices Wiring Standard 25-pin Cable Connection 9-pin Cable Connection F300-E RS-232C Device RS-232C Device F300-E Symbol Pin no. Pin no. Symbol Symbol Pin no. SD (TXD) 2 2 SD (TXD)...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z104-01_f200.pdf

マニュアル
PDF[Z122-E1-01A] V600-CH1D Hand-held Reader Writer Op...
...Sending data SD Host device → Hand-held Reader Writer 4 --- --- --- 5 Signal ground SG --- 6 Data set enable DS 7 8 9 Request sending Clear to send --- RS CS --- Host device ← Hand-held Reader Writer Repeat p in the connector section. --- --- Transmission Specifications Transmission with the currently available V600-series Data Carriers is possible. 2-6-1 Transmission Distances Data Carrier Note Transmission distances V600-D23P53 0 to 2.5 mm V600-D23P54 0 to 4 mm V600-D23P61 0 to 11 mm V600-D23P66 0 to 17 mm (see note 2) V600-D23P66SP 0 to 12 mm V600-D23P71...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z122-e1-01a_v600-ch1d.pdf

マニュアル
PDFz129-e1-02_v600-ham42-drt.pdf
...2-1 Amplifiers 2-1-1 Names and Functions of Components Component Names DeviceNet (CompoBus/D) Connector For connecting to DeviceNet. Data Indicators Green: Read data displayed in bit units. Red: Flashes to show error classification (bits 0 to 7 only). ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z129-e1-02_v600-ham42-drt.pdf

マニュアル
PDF[Z144-E1-04] F160 Vision Sensor Setup Manual
... for RS-232C or RS-422 RS-232C Wiring F160 External device Signal Pin SD 2 SD RD 3 RD GND 9 GND Pin Use only shielded cable. 36 Signal RS/CS control cannot be used. Section 4-2 Connecting through the Serial Interface RS-422 Wiring F160 Signal External device Pin Pin Signal RDB 5 RDB RDA 6 RDA SDB 7 SDB SDA 8 SDA GND 9 GND Use only shielded cable. Note Pin numbers on the external device will depend on the device being connected. Refer to the manual for the personal computer or PLC being connected....

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z144-e1-04_f160.pdf

マニュアル
PDF[Z148-E1-06] V670-CD1D-V1/H11/H51(Q)/D13F03/D13F01...
...Pin No. Ground for maintenance or ground GR — — Shield Ground for signal or common return SG — — 5 Send data SD — Receive data RD Request to send RS Clear to send CS 3 — — 2 7 — 8 Controller Pin Layout (TOP VIEW) Note 1: To prevent an operation error, ground the shielded wire either at the controller side or the computer side mentioned above. (The figure above shows an example of grounding the shielded wire at the ID controller side.) Note 2: Short-circuit pin No. 7 (RS) and pin No. 8 (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z148-e1-06_v670-cd1d-v1_h11_h51(q)_d13f0_(h).pdf

マニュアル
PDF[Z149-E1-02] V690-HMG01A/D8KR01A/L01 Microwave RFI...
...) Plug (Female) 1 2 RD (Receiving) TX (Sending) 3 SD (Sending) RX (Receiving) SG (Signal ground) SG (Signal ground) 4 View from connecting side 5 6 7 RS (Request to send) 8 CS (Clear to send) 9 5-6 Loop back (Short-circuit) 5-2 Wiring the Host (2) Using RS-232C Connecting Cable to Extend a Cable and Connecting to IBM PC/AT or Compatible (Typical) To connect an IBM PC/AT or compatible (typical) extending a RS-232C Connecting Cable, prepare the cables as shown below. The wires in the cable must be AWG26 or thicker. Cable ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z149-e1-02_v690-hmg01a_d8kr01a_l01.pdf

マニュアル
PDF[Z150-E1-01] V530-C300E 2-Dimensional Code Reader ...
...-0901 Hood XM2S-0911 Pin 16 Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Section 3-1 RS-232C Specifications 3-1-2 Wiring Only use a shielded RS-232C cable. Standard Connections V530-C300E Signal External device Pin Pin Signal Shield Connections for RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z150-e1-01_v530-c300e.pdf

マニュアル
PDFz152-e1-02_e3x-drt21_srt21_cif11.pdf
... Amplifier Units can also be connected to a Fiber Amplifier Sensor Communication Unit. 1-1-2 Features Communications between a Host and Optical Sensors The Fiber Amplifier Sensor Communication Unit enables communications between optical sensors and a host, such as an OMRON PLC (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z152-e1-02_e3x-drt21_srt21_cif11.pdf

マニュアル
PDF[Z158-E1-02D] Z500-MC10E/MC15E Profile Measuring S...
... No. Signal 1 FG (GND) Protective frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 5 4 3 2 1 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Use a compatible connector. Recommended Plug and Hood Type 52 Z500 Setup Manual Function Manufacturer Model Plug OMRON Corp. XM2A-0901 Hood OMRON Corp. XM2S-0911 Z158-E1-02C.book Page 53 Wednesday, August 9, 2006 6:13 PM SECTION 3 Connecting External Devices 3-2-2 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z158-e1-02d_z500-mc10e_15e.pdf

マニュアル
PDF[Z159-E1-02] Z500-MC10E/MC15E Profile Measuring Sy...
...Data length 7, 8* bit Parity bit None*, Even, Odd Stop bits 1*, 2 bit Delimiter CR*, LF, CR+LF Set the same settings that are set in the personal computer. None* Flow control is not performed. RS/CS Flow control performed by the hardware. Use a cable that connects the Z500 and the RS signals and ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z159-e1-02_z500-mc10e_15e.pdf

マニュアル
PDF[Z161-E1-03B] Z300 V3 High-precision Visual Displ...
...Model Manufacturer Plug: XM2A-0901 OMRON Corp. Hood: XM2S-0911 Pin No. Signal 1 FG(GND) 2 3 4 5 6 7 8 9 SD(TXD) RD(RXD) RS(RTS) CS(CTS) NC NC NC SG(GND) Name Protective frame ground Send Data Receive Data Request to Send Clear to Send Not connected Not connected Not connected Signal ground 41 Section 2-6 RS-232C Wiring 2-6-2 Wiring Only use a shielded RS-232C cable. The maximum cable length is 15 m. Standard Wiring Z300 External device Signal Pin No. Pin No. Signal SD(TXD) 2 ∗ SD(TXD)...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z161-e1-03b_z300_v3.pdf

マニュアル
PDF[Z162-E1-02] Z300 V3 High-precision Visual Displac...
..., refer to page 157. Item Selection 2400, 4800, 9600, Baud rate 19200, 38400* bps Data length 7, 8* bit Parity bit None*, even, odd Stop bits 1*, 2 bit Delimiter CR*, LF, CR+LF None* RS/CS Flow control Xon/Xoff None* Value Result Value+Result Out on Hold OUT0* OUT1 OUT setting OUT2 OUT3 OUT0 to 3 Description Set the same settings that are set in the personal computer. Flow control is not performed. Flow control performed by the hardware. Use a cable that connects the Z300 and the RS signals and ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z162-e1-02_z300_v3.pdf

マニュアル
PDF[Z169-E1-04] V530-R160E/R160EP 2D Code Reader User...
...SD 2 2 RD RD 3 3 SD NC 4 4 ER RDB(RD+) 5 5 SG GND 9 6 DR Hood − 7 RS 8 CS Hood − Use a shielded cable. 62 V530-R160 Operation Manual SECTION 3 Connection to the Host  1:1 Connection (Programmable Controller) V530-R160 RS-232C cable XW2Z-200T (2 m) XW2Z-500T (5 m) Programmable Controller V530-R160 CS1H-CPU** C200H-PA** SECTION 3 CPU Unit: Power Supply Unit: or CPU Unit: Power Supply Unit: CQM1H-CPU** CQM1-PA**  RS-232C Cable Wiring (XW2Z-200T/XW2Z-500T) Connecting through the Serial Interface...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z169-e1-04_v530-r160e_-r160ep.pdf

マニュアル
PDF[Z170-E1-02E] F160-2 Vision Sensor Setup Manual
... for RS-232C or RS-422 RS-232C Wiring F160 External device Signal Pin SD 2 SD RD 3 RD GND 9 GND Pin Use only shielded cable. 36 Signal RS/CS control cannot be used. Section 4-2 Connecting through the Serial Interface RS-422 Wiring F160 Signal External device Pin Pin Signal RDB 5 RDB RDA 6 RDA SDB 7 SDB SDA 8 SDA Use only shielded cable. Note Pin numbers on the external device will depend on the device being connected. Refer to the manual for the personal computer or PLC being connected. 4-2-4...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z170-e1-02e_f160-2.pdf

マニュアル
PDF[Z178-E1-01A] Z550 Multi-Dimensional Sensor Setup ...
...㪍 㪈 Pin No. Signal name Function 1 FG (GND) Protective frame ground 2 SD (TXD) Transmission data 3 RD (RXD) Reception data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Use a compatible connector. Recommended Model Manufacturer 34 Model Plug OMRON Corporation XM2A-0901 Hood OMRON Corporation XM2S-0911 Setup Manual SECTION 3 Connecting External Devices Wiring The maximum cable length is 15 m. Standard Controller Signal External device Pin No. Pin No. Signal 2 * SD(TXD) RD(...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z178-e1-01a_z550.pdf

マニュアル
PDF[Z179-E1-01] Z550 Multi-Dimensional Sensor Operati...
... the same as on the PC side. Parity None (default setting) Even, Odd Stop bits 1 bit (default setting), 2 bits Delimiter CR (default setting), LF, CR + LF Flow None(default setting) The flow control is not performed. RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z179-01_z550.pdf

マニュアル
PDF[Z189-E1-02] Z550-MC10/MC15 Multi-Dimensional Sens...
...㪍 㪈 Pin No. Signal name Function 1 FG (GND) Protective frame ground 2 SD (TXD) Transmission data 3 RD (RXD) Reception data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Use a compatible connector. Recommended Model Manufacturer 38 Z550 Model Plug OMRON Corporation XM2A-0901 Hood OMRON Corporation XM2S-0911 Setup Manual setup.book Page 39 Friday, June 3, 2005 5:22 PM SECTION 3 Connecting External Devices Wiring The maximum cable length is 15 m. Standard Controller...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z189-e1-02_z550-mc10_15.pdf

マニュアル
PDF[Z190-E1-02] Z550-MC10/MC15 Multi-Dimensional Sens...
... the same as on the PC side. Parity None (default setting) Even, Odd Stop bits 1 bit (default setting), 2 bits Delimiter CR (default setting), LF, CR + LF Flow None(default setting) The flow control is not performed. RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z190-e1-02_z550-mc10_15.pdf

マニュアル
PDFz194-e1-03_v600-idsc02_04.pdf
...GR Signal ground or common return SG line Send data SD ----- ----- 1 9 --- ❍ 2 Receive data Request to send RD RS ❍ --- --❍ 3 4 Can send 5V CS 5V ❍ --- --❍ 5 6 Section 3-3 RS-232C Interface Connections Connecting a Single ID Controller Only RS-232C port RS232C SYSMAC CJ1G-CPU44 PROGRAMMABLE CONTROLLER OPEN RUN ERR/ALM INH PRPHL COMM BKUP IN OUT 0 1 2 3 4 0 1 2 5 6 7 8 9 3 4 5 V600C12 RUN ERC ERP ERH T/R NORM/ERR HEAD1 HEAD2 T/R NORM/ERR SW SETTING DAT MCPWR BUSY TEST ON...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z194-e1-03_v600-idsc02_04.pdf

マニュアル
PDF[Z213-E1-01B] V700-L11/HMD13[]/HMD11-1/D23P41-1 RF...
...ID tag Link unit Max. 31 units IDRW head 24 VDC Precautions for trouble-free operation For a 1:N connection involving a link unit, it is necessary to add an normal controlled RS signal from an upstream controller to a ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z213-e1-01b_v700-l11_hmd1___d23p41-1.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。