全 2685 件が検索されました。(2361 - 2380件を表示)
- マニュアル
...-0911 Pin 48 Model No. Plug Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Section 4-1 Specifications 4-1-2 Wiring Only use a shielded RS-232C cable. Standard Connections V530-R150 Signal External device Pin Pin Signal Shield Connections for RS/...
- マニュアル
... No. Signal 1 FG (GND) Protective frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 5 4 3 2 1 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Use a compatible connector. Recommended Plug and Hood Type 52 Z500 Setup Manual Function Manufacturer Model Plug OMRON Corp. XM2A-0901 Hood OMRON Corp. XM2S-0911 Z158-E1-02C.book Page 53 Wednesday, August 9, 2006 6:13 PM SECTION 3 Connecting External Devices 3-2-2 ...
- マニュアル
...Data length 7, 8* bit Parity bit None*, Even, Odd Stop bits 1*, 2 bit Delimiter CR*, LF, CR+LF Set the same settings that are set in the personal computer. None* Flow control is not performed. RS/CS Flow control performed by the hardware. Use a cable that connects the Z500 and the RS signals and ...
- マニュアル
...Model Manufacturer Plug: XM2A-0901 OMRON Corp. Hood: XM2S-0911 Pin No. Signal 1 FG(GND) 2 3 4 5 6 7 8 9 SD(TXD) RD(RXD) RS(RTS) CS(CTS) NC NC NC SG(GND) Name Protective frame ground Send Data Receive Data Request to Send Clear to Send Not connected Not connected Not connected Signal ground 41 Section 2-6 RS-232C Wiring 2-6-2 Wiring Only use a shielded RS-232C cable. The maximum cable length is 15 m. Standard Wiring Z300 External device Signal Pin No. Pin No. Signal SD(TXD) 2 ∗ SD(TXD)...
- マニュアル
..., refer to page 157. Item Selection 2400, 4800, 9600, Baud rate 19200, 38400* bps Data length 7, 8* bit Parity bit None*, even, odd Stop bits 1*, 2 bit Delimiter CR*, LF, CR+LF None* RS/CS Flow control Xon/Xoff None* Value Result Value+Result Out on Hold OUT0* OUT1 OUT setting OUT2 OUT3 OUT0 to 3 Description Set the same settings that are set in the personal computer. Flow control is not performed. Flow control performed by the hardware. Use a cable that connects the Z300 and the RS signals and ...
- マニュアル
...SD 2 2 RD RD 3 3 SD NC 4 4 ER RDB(RD+) 5 5 SG GND 9 6 DR Hood − 7 RS 8 CS Hood − Use a shielded cable. 62 V530-R160 Operation Manual SECTION 3 Connection to the Host 1:1 Connection (Programmable Controller) V530-R160 RS-232C cable XW2Z-200T (2 m) XW2Z-500T (5 m) Programmable Controller V530-R160 CS1H-CPU** C200H-PA** SECTION 3 CPU Unit: Power Supply Unit: or CPU Unit: Power Supply Unit: CQM1H-CPU** CQM1-PA** RS-232C Cable Wiring (XW2Z-200T/XW2Z-500T) Connecting through the Serial Interface...
- マニュアル
... for RS-232C or RS-422 RS-232C Wiring F160 External device Signal Pin SD 2 SD RD 3 RD GND 9 GND Pin Use only shielded cable. 36 Signal RS/CS control cannot be used. Section 4-2 Connecting through the Serial Interface RS-422 Wiring F160 Signal External device Pin Pin Signal RDB 5 RDB RDA 6 RDA SDB 7 SDB SDA 8 SDA Use only shielded cable. Note Pin numbers on the external device will depend on the device being connected. Refer to the manual for the personal computer or PLC being connected. 4-2-4...
- マニュアル
...z174-e1-02a_cs1w_cj1w-v600c1_.pdf Cat. No. Z174-E1-02A SYSMAC CS/CJ Series CS1W-V600C11 CS1W-V600C12 CJ1W-V600C11 CJ1W-V600C12 ID Sensor Units SYSMAC CS/CJ Series ID Sensor Units Operation Manual Revised December 2004 iv READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by ...
- マニュアル
...㪍 㪈 Pin No. Signal name Function 1 FG (GND) Protective frame ground 2 SD (TXD) Transmission data 3 RD (RXD) Reception data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Use a compatible connector. Recommended Model Manufacturer 34 Model Plug OMRON Corporation XM2A-0901 Hood OMRON Corporation XM2S-0911 Setup Manual SECTION 3 Connecting External Devices Wiring The maximum cable length is 15 m. Standard Controller Signal External device Pin No. Pin No. Signal 2 * SD(TXD) RD(...
- マニュアル
... the same as on the PC side. Parity None (default setting) Even, Odd Stop bits 1 bit (default setting), 2 bits Delimiter CR (default setting), LF, CR + LF Flow None(default setting) The flow control is not performed. RS/...
- マニュアル
...㪍 㪈 Pin No. Signal name Function 1 FG (GND) Protective frame ground 2 SD (TXD) Transmission data 3 RD (RXD) Reception data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Use a compatible connector. Recommended Model Manufacturer 38 Z550 Model Plug OMRON Corporation XM2A-0901 Hood OMRON Corporation XM2S-0911 Setup Manual setup.book Page 39 Friday, June 3, 2005 5:22 PM SECTION 3 Connecting External Devices Wiring The maximum cable length is 15 m. Standard Controller...
- マニュアル
... the same as on the PC side. Parity None (default setting) Even, Odd Stop bits 1 bit (default setting), 2 bits Delimiter CR (default setting), LF, CR + LF Flow None(default setting) The flow control is not performed. RS/...
- マニュアル
...GR Signal ground or common return SG line Send data SD ----- ----- 1 9 --- ❍ 2 Receive data Request to send RD RS ❍ --- --❍ 3 4 Can send 5V CS 5V ❍ --- --❍ 5 6 Section 3-3 RS-232C Interface Connections Connecting a Single ID Controller Only RS-232C port RS232C SYSMAC CJ1G-CPU44 PROGRAMMABLE CONTROLLER OPEN RUN ERR/ALM INH PRPHL COMM BKUP IN OUT 0 1 2 3 4 0 1 2 5 6 7 8 9 3 4 5 V600C12 RUN ERC ERP ERH T/R NORM/ERR HEAD1 HEAD2 T/R NORM/ERR SW SETTING DAT MCPWR BUSY TEST ON...
- マニュアル
...Signal name 4-4 ZS-DSU User’s Manual 8 9 Signal name NC SD(TXD) 2 2 RD(RXD) RD(RXD) 3 3 SD(TXD) RS(RTS) 4 4 NC CS(CTS) 5 5 SG(GND) NC 6 6 NC NC 7 7 RS(RTS) NC 8 8 CS(CTS) SG(GND) NC 9 9 NC 10 Section 4 RS-232C Input/Output Setting the Communication Specifications Set the RS-232C communications specifications. Match the communication specifications of the ZS-DSU to those of the external device. FUN Mode-[SYSTEM]-[COM] Setting RS232C Range LENGTH 8BIT, 7BIT (default value: ...
- マニュアル
...ID tag Link unit Max. 31 units IDRW head 24 VDC Precautions for trouble-free operation For a 1:N connection involving a link unit, it is necessary to add an normal controlled RS signal from an upstream controller to a ...
- マニュアル
... data RD Input 3 Send data SD Output 4 − 5 Signal ground 6 − 7 8 − Output SG − − Input Request send RS Output Clear to send (CS) Input 9 Comment
Normally OFF Leave this pin OPEN. Normally OPEN during service Not functioning Unused 2.1 CIDRW controller: Model V700-L21 Character format (E4 SECS I, fixed) Section 2 Communication standard ■ Cable connection example Connect the upstream controller to the CIDRW controller using the cable whose configuration is specified below. Limit the whole cable length to 15 m. Symbol DOS/V PC D-SUB... - マニュアル
...,600 bps (Use initial setting.) Data length 8 bits (Use initial setting.) Parity Even L3 Stop bits 1 bit (Use initial setting.) Header None (Use initial setting.) Footer CR (Use initial setting.) RS/CS...
- マニュアル
... Hand-held Reader Writer 4 --- --- --- 5 Signal ground SG --- Data set ready DS Hand-held Reader Writer to host device 7 Request send RS Loops inside connector 8 Enable send CS 9 --- --- 3 9 Code (See note.) Receive data 2 6 6 --- Note: The names of signals at the host device are abbreviated with codes. Note: For conversion to a 25-pin connector, the SGC-X9P/25P-2 manufactured by Sunhayato, or an equivalent, is recommended. 36 Pin No. RFID System User's Manual Section 2 Communications Preparations •Connection with the Host Device Use the following procedure to connect ...
- マニュアル
... common retrace line SG No No 5 Send data SD No Yes 3 Receive data RD Yes No 2 Request to send RS No Yes 7 Clear to send CS Yes No 8 Connector Pin Arrangement When Viewed from the Controller ID Controller Host device Shield (Shielded wire) Note 1. Ground the shielded wire on either the Controller side or the host device side to prevent operation errors. Note 2. Internally short-circuit pins 7 (RS) and 8 (...
- マニュアル
... a cordless connector (E3X-CN02). Device Net Optical Communication PLC 16 E3X-DRT21-S User’s Manual Section 1 Features and System Configuration Features Section 1 Overview ■ This unit enables a communication interface between OMRON's PLCs (...