ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 2750 件が検索されました。(2381 - 2400件を表示)
マニュアル
PDF[Z159-E1-02] Z500-MC10E/MC15E Profile Measuring Sy...
...Data length 7, 8* bit Parity bit None*, Even, Odd Stop bits 1*, 2 bit Delimiter CR*, LF, CR+LF Set the same settings that are set in the personal computer. None* Flow control is not performed. RS/CS Flow control performed by the hardware. Use a cable that connects the Z500 and the RS signals and ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z159-e1-02_z500-mc10e_15e.pdf

マニュアル
PDF[Z161-E1-03B] Z300 V3 High-precision Visual Displ...
...Model Manufacturer Plug: XM2A-0901 OMRON Corp. Hood: XM2S-0911 Pin No. Signal 1 FG(GND) 2 3 4 5 6 7 8 9 SD(TXD) RD(RXD) RS(RTS) CS(CTS) NC NC NC SG(GND) Name Protective frame ground Send Data Receive Data Request to Send Clear to Send Not connected Not connected Not connected Signal ground 41 Section 2-6 RS-232C Wiring 2-6-2 Wiring Only use a shielded RS-232C cable. The maximum cable length is 15 m. Standard Wiring Z300 External device Signal Pin No. Pin No. Signal SD(TXD) 2 ∗ SD(TXD)...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z161-e1-03b_z300_v3.pdf

マニュアル
PDF[Z162-E1-02] Z300 V3 High-precision Visual Displac...
..., refer to page 157. Item Selection 2400, 4800, 9600, Baud rate 19200, 38400* bps Data length 7, 8* bit Parity bit None*, even, odd Stop bits 1*, 2 bit Delimiter CR*, LF, CR+LF None* RS/CS Flow control Xon/Xoff None* Value Result Value+Result Out on Hold OUT0* OUT1 OUT setting OUT2 OUT3 OUT0 to 3 Description Set the same settings that are set in the personal computer. Flow control is not performed. Flow control performed by the hardware. Use a cable that connects the Z300 and the RS signals and ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z162-e1-02_z300_v3.pdf

マニュアル
PDF[Z169-E1-04] V530-R160E/R160EP 2D Code Reader User...
...SD 2 2 RD RD 3 3 SD NC 4 4 ER RDB(RD+) 5 5 SG GND 9 6 DR Hood − 7 RS 8 CS Hood − Use a shielded cable. 62 V530-R160 Operation Manual SECTION 3 Connection to the Host  1:1 Connection (Programmable Controller) V530-R160 RS-232C cable XW2Z-200T (2 m) XW2Z-500T (5 m) Programmable Controller V530-R160 CS1H-CPU** C200H-PA** SECTION 3 CPU Unit: Power Supply Unit: or CPU Unit: Power Supply Unit: CQM1H-CPU** CQM1-PA**  RS-232C Cable Wiring (XW2Z-200T/XW2Z-500T) Connecting through the Serial Interface...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z169-e1-04_v530-r160e_-r160ep.pdf

マニュアル
PDF[Z170-E1-02E] F160-2 Vision Sensor Setup Manual
... for RS-232C or RS-422 RS-232C Wiring F160 External device Signal Pin SD 2 SD RD 3 RD GND 9 GND Pin Use only shielded cable. 36 Signal RS/CS control cannot be used. Section 4-2 Connecting through the Serial Interface RS-422 Wiring F160 Signal External device Pin Pin Signal RDB 5 RDB RDA 6 RDA SDB 7 SDB SDA 8 SDA Use only shielded cable. Note Pin numbers on the external device will depend on the device being connected. Refer to the manual for the personal computer or PLC being connected. 4-2-4...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z170-e1-02e_f160-2.pdf

マニュアル
PDF[Z178-E1-01A] Z550 Multi-Dimensional Sensor Setup ...
...㪍 㪈 Pin No. Signal name Function 1 FG (GND) Protective frame ground 2 SD (TXD) Transmission data 3 RD (RXD) Reception data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Use a compatible connector. Recommended Model Manufacturer 34 Model Plug OMRON Corporation XM2A-0901 Hood OMRON Corporation XM2S-0911 Setup Manual SECTION 3 Connecting External Devices Wiring The maximum cable length is 15 m. Standard Controller Signal External device Pin No. Pin No. Signal 2 * SD(TXD) RD(...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z178-e1-01a_z550.pdf

マニュアル
PDF[Z179-E1-01] Z550 Multi-Dimensional Sensor Operati...
... the same as on the PC side. Parity None (default setting) Even, Odd Stop bits 1 bit (default setting), 2 bits Delimiter CR (default setting), LF, CR + LF Flow None(default setting) The flow control is not performed. RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z179-01_z550.pdf

マニュアル
PDF[Z189-E1-02] Z550-MC10/MC15 Multi-Dimensional Sens...
...㪍 㪈 Pin No. Signal name Function 1 FG (GND) Protective frame ground 2 SD (TXD) Transmission data 3 RD (RXD) Reception data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Use a compatible connector. Recommended Model Manufacturer 38 Z550 Model Plug OMRON Corporation XM2A-0901 Hood OMRON Corporation XM2S-0911 Setup Manual setup.book Page 39 Friday, June 3, 2005 5:22 PM SECTION 3 Connecting External Devices Wiring The maximum cable length is 15 m. Standard Controller...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z189-e1-02_z550-mc10_15.pdf

マニュアル
PDF[Z190-E1-02] Z550-MC10/MC15 Multi-Dimensional Sens...
... the same as on the PC side. Parity None (default setting) Even, Odd Stop bits 1 bit (default setting), 2 bits Delimiter CR (default setting), LF, CR + LF Flow None(default setting) The flow control is not performed. RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z190-e1-02_z550-mc10_15.pdf

マニュアル
PDFz194-e1-03_v600-idsc02_04.pdf
...GR Signal ground or common return SG line Send data SD ----- ----- 1 9 --- ❍ 2 Receive data Request to send RD RS ❍ --- --❍ 3 4 Can send 5V CS 5V ❍ --- --❍ 5 6 Section 3-3 RS-232C Interface Connections Connecting a Single ID Controller Only RS-232C port RS232C SYSMAC CJ1G-CPU44 PROGRAMMABLE CONTROLLER OPEN RUN ERR/ALM INH PRPHL COMM BKUP IN OUT 0 1 2 3 4 0 1 2 5 6 7 8 9 3 4 5 V600C12 RUN ERC ERP ERH T/R NORM/ERR HEAD1 HEAD2 T/R NORM/ERR SW SETTING DAT MCPWR BUSY TEST ON...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z194-e1-03_v600-idsc02_04.pdf

マニュアル
PDF[Z213-E1-01B] V700-L11/HMD13[]/HMD11-1/D23P41-1 RF...
...ID tag Link unit Max. 31 units IDRW head 24 VDC Precautions for trouble-free operation For a 1:N connection involving a link unit, it is necessary to add an normal controlled RS signal from an upstream controller to a ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z213-e1-01b_v700-l11_hmd1___d23p41-1.pdf

マニュアル
PDF[Z214-E1-01B] V700-L11/L21/HMD13[]/HMD11-1/D23P41 ...
... data RD Input 3 Send data SD Output 4 − 5 Signal ground 6 − 7 8 − Output SG − − Input Request send RS Output Clear to send (CS) Input 9 Comment Normally OFF Leave this pin OPEN. Normally OPEN during service Not functioning Unused 2.1 CIDRW controller: Model V700-L21 Character format (E4 SECS I, fixed) Section 2 Communication standard ■ Cable connection example Connect the upstream controller to the CIDRW controller using the cable whose configuration is specified below. Limit the whole cable length to 15 m. Symbol DOS/V PC D-SUB...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z214-e1-01b_v700-l21_l11_hmd1___d23p41.pdf

マニュアル
PDF[Z217-E1-01] V700-L12 ID Link Unit User's Manual
...,600 bps (Use initial setting.) Data length 8 bits (Use initial setting.) Parity Even L3 Stop bits 1 bit (Use initial setting.) Header None (Use initial setting.) Footer CR (Use initial setting.) RS/CS...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z217-e1-01_v700-l12.pdf

マニュアル
PDFz219-e1-05_v600-chud_ch1d-v2_ch1d-psi.pdf
... Hand-held Reader Writer 4 --- --- --- 5 Signal ground SG --- Data set ready DS Hand-held Reader Writer to host device 7 Request send RS Loops inside connector 8 Enable send CS 9 --- --- 3 9 Code (See note.) Receive data 2 6 6 --- Note: The names of signals at the host device are abbreviated with codes. Note: For conversion to a 25-pin connector, the SGC-X9P/25P-2 manufactured by Sunhayato, or an equivalent, is recommended. 36 Pin No. RFID System User's Manual Section 2 Communications Preparations •Connection with the Host Device Use the following procedure to connect ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z219-e1-05_v600-chud_ch1d-v2_ch1d-psi.pdf

マニュアル
PDF[Z221-E1-01] V680-CA1D/CA2D/H01/D1KP58HT Heat-resi...
... common retrace line SG No No 5 Send data SD No Yes 3 Receive data RD Yes No 2 Request to send RS No Yes 7 Clear to send CS Yes No 8 Connector Pin Arrangement When Viewed from the Controller ID Controller Host device Shield (Shielded wire) Note 1. Ground the shielded wire on either the Controller side or the host device side to prevent operation errors. Note 2. Internally short-circuit pins 7 (RS) and 8 (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z221-e1-01_v680-ca_d_h01_d1kp58ht.pdf

マニュアル
PDFz223-e1-03_e3x-drt21-s.pdf
... a cordless connector (E3X-CN02). Device Net Optical Communication PLC 16 E3X-DRT21-S User’s Manual Section 1 Features and System Configuration Features Section 1 Overview ■ This unit enables a communication interface between OMRON's PLCs (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z223-e1-03_e3x-drt21-s.pdf

マニュアル
PDF[Z228-E1-03] V400-H111/H211 Handheld 2D Code Reade...
... compatible D-sub, 9-pin Name Pin No. Name - 1 SD RD 2 RD SD 3 SG ER 4 +5 V SG 5 DR 6 RS 7 CS 8 - 9 Shield wire Connector cover 0V +5 V (View of mating section) 20 V400-H111/211 User’s Manual user_en.book Page 21 Tuesday, April 17, 2007 11:35 AM Section 2 Installation and Connections Connecting a Personal Computer (V400-W22-2M/5M Cable) Section 2 Cable • Connector The connector used for V400-W22-2M and V400-W22-5M cables is a D-sub 9-pin connector (female). The ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z228-e1-03_v400-h111_h211.pdf

マニュアル
PDF[Z235-E1-02] V750-BA50C04-US, V740-HS01CA/HS01LA R...
...1 --- --- --- 2 RD Receive Data IN 3 SD Send Data 4 --- --- --- 5 SG Signal Ground --- 6 --- --- --- 7 RS Request to Send 8 CS Clear to Send IN 9 --- --- --- OUT OUT UHF RFID System User's Manual 21 SECTION 2 Specifications and Performance (3) Ethernet Interface This port is used to connect the host to the reader via Ethernet. To connect them, use the commercial cable 10/10Base-T.  Connector: RJ-45 (8 pin) LINK LED LED: Link (green) /Act (orange) ACT LED SECTION 2 Reader Pin No. Name Function I/O 1 TXD(+) Transmit Data + OUT 2 TXD(-) Transmit ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z235-e1-02_v750-ba50c04-us.pdf

マニュアル
PDF[Z240-E1-05] ZFV-C Smart Sensors (with Ultra-High-...
...Signal name 3 7 4 8 5 9 Signal name NC SD(TXD) 2 2 SD(TXD) RD(RXD) 3 3 RD(RXD) RS(RTS) 4 4 RS(RTS) CS(CTS) 5 5 CS(CTS) NC 6 6 NC NC 7 7 NC NC 8 8 NC SG(GND) NC 9 9 SG(GND) 10 Note 1: A plug type connector is used for the PLC side. ZFV-C User’s Manual 105 Section 5 Setting USB/RS-232C Communication Specifications ● RS-232C cable for connecting a personal computer • ZS-XRS2 (cable length: 2 m) Amplifier unit side PC side (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z240-e1-05_zfv-c.pdf

マニュアル
PDF[Z242-E1-04] V400-F050/F250/F350 2D Code Reader Us...
...-pin Name Pin No. Name - 1 SD RD 2 RD SD 3 +24V ER 4 GND SG 5 TRIG DR 6 RESET RS 7 RUN CS 8 OK/NG - 9 ERROR Shield wire Connector cover BUSY +24 V (Brown) 0 V (Blue) Not used with RS-232C communication. TRIG (Pink) RESET (Orange) RUN (Green) OK/NG (Black) ERROR (Gray) BUSY (Yellow) (View of mating section) 60 V400-F050/250/350 User’s Manual Section 5 Communicating with PC and Programmable Controller Programmable Controller A D-SUB 9-pin connector (male) is used for the cable type V400-W23 (NPN ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z242-e1-04_v400-f050_f250_f350.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。