PDF[W306-E1-03] C200H-ASC11/ASC21/ASC31 ASCII Units O...
... match the external device interface. C200H-ASC11/21 1 C200H-ASC31 6 9 9 6 5 5 Pin 1 Symbol Name Direction Frame ground Comments 1 FG - 2 SD Send data Output 3 RD Receive data Input 4 RTS Request to send Output 5 CTS Clear to send Input 6 - Not used - Only for terminal port of C200H-ASC31. 5V 5V output Output Other ports 7 DSR Data set ready Input 8 DTR Data terminal ready Output 9 SG Signal ground - Hood FG Frame ground - RS-232C Interface Specifications Item Specifications Electrical characteristics Conform to EIA RS-232C Synchronization...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w306-03_c200h-asc11_21_31.pdf

マニュアル
PDF[W314-E1-01] C200H-MC221 Motion Control Unit Opera...
...-sub connector (female) IBM PC/AT or compatible Connect as shown below. Connector for the personal computer IBM PC/AT Computer Female 25-pin CV500-CIF01 Female 25-pin RS-232C Connector Computer 2 SD 3 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w314-e1-01_c200h-mc221.pdf

マニュアル
PDF[W315-E1-03] C200H-MC221 Motion Control Unit Opera...
... for the personal computer 24 Connecting the Teaching Box Section 3-2 Wire the following. RS-232C MC Unit side (20 pins) Personal computer side (9 pins) 1 Connector hood 2 RD 2 3 SD 3 7 RS 4 8 CS 5 5 SG 6 6 DR 7 4 ER Connector hood 8 9 10 11 12 Shielded wires (see note) 13 14 15 16 17 18 19 20 Note Connect the shielded line to the FG (pin 1) at the computer, and to the connector hood at the MC Unit. 3-2 Connecting the Teaching Box The procedure ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w315-e1-03_c200h-mc221.pdf

マニュアル
PDFw343-e1-07_cs1w_cj1w-etn.pdf
...35 15 101 (16.5 including cover) (Unit: mm) 130 CS1W-ETN11 35 101 (Unit: mm) 9 Section 1-6 Software Configuration CJ1W-ETN11 65 2.7 31 ETN11 RUN ERC SD RD ERH TCP FTP EF012 6789 345 ABCD EF012 6789 345 TS UNIT No. NODE No. x161 ABCD EF012 6789 345 ABCD 90 x160 2.7 ETHERNET 1-6 (Unit: mm) Software Configuration The software supported by the Ethernet Unit runs in the layers shown in the following diagram. The components that form the various layers are defined below the diagram. Memory Card/ EM File Memory CS/CJ-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w343-e1-07_cs1w_cj1w-etn.pdf

マニュアル
PDF[W370-E1-07] CS1W-CLK12-V1/CLK13/CLK52-V1/CLK53, C...
... interface error, EEPROM error, unit number error, I/O table not set, duplex communications setting error, or duplex settings incomplete INS (network participation) Yellow Not lit Lit No error. Unit is participating (inserted) in the network. Not lit ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w370-e1-07_cs1w-clk__(-v1)_cvm1-clk_2.pdf

マニュアル
PDF[W377-E1-04] CPM2C-S100C(-DRT)/S110C(-DRT) Program...
... included with the CPU Unit or an equivalent connector to connect to the DeviceNet transmission line. 5. PC Status Indicators The following indicators show the operating status of the PC. Indicator PWR (green) RUN (green) ERR/ALM (red) ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w377-e1-04_cpm2c_s.pdf

マニュアル
PDF[W406-E1-10] CS1W-LCB0[], CS1D-CPU[][][]P, CJ1G-CP...
.... When constructing an intranet, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. Take adequate measures, such as restricting physical access to network devices, by means such as locking the installation area. When using a device equipped with the ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w406-e1-10_cs1w-lcb_cs1d-cpu_cs1g-cpu.pdf

マニュアル
PDFw420-e1-06_cs1w_cj1w-etn21.pdf
... mm (W × H × D) Conform to general specifications for the SYSMAC CJ Series. 14 Section 1-4 Specifications 1-4-2 Dimensions CS1W-ETN21 ETN21 100M ERH TCP FTP HOST RUN ERC SD RD LNK UNIT NO. 0 1 ×161 ×160 130 NODE NO. 0 100BASE-TX 10BASE-T 35 101 (Unit: mm) CJ1W-ETN21 Back Front • Unit Version 1.5 or Later ETN21 65 31 2.7 2.7 31 • Unit Version 1.4 or Earlier ETN21 ERC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w420-e1-06_cs1w_cj1w-etn21.pdf

マニュアル
PDF[W434-E1-01] CVM1-LK401 PC Link Unit Operation Man...
...164 174 188 78 Terminating resistance selector switch RS422 63 Approx. 140 10 dia. Appendix B Link Adapter Specifications Internal Structure RS-232C Pin Name 1 FG 2 SD 3 RD 4 RS 5 CS 6 DR 7 SG 8 CD 20 ER ● CTS (CS) Selector Set to 0 V to have the clear-to-send (CTS) signal always ON. Set to external to receive an external CTS signal. ● Terminating Resistance Selector When set to ON, connects the builtin terminating resistance (220 Ω); when set to OFF, disconnects it. ● Power Supply Connection RS-422 OR/ Switching circuit External CTS Selector 0V...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w434-e1-01_cvm1.pdf

マニュアル
PDF[Z076-E1-01] E5AX Temperature Controller Operation...
... EIA RS-232C. Communications Signals 1 13 25 14 Signal Abbreviation Signal direction Pin no. Frame ground (safety ground) FG ––– 1 Signal ground or common return SG ––– 7 Send data SD Output 2 Receive data RD Input 3 Request to send RS Output 4 Clear to send CS Input 5 Data set ready DR Input 6 Data terminal ready ER Output 20 Connection Diagram The following diagram shows how the E5AX is connected to the host computer using the RS-232C. Host computer RS-232C Abbreviation E5AX RS-232C Pin no. Pin Abbrevino. ation 1 1 FG SG 7...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z076-e1-01_e5ax.pdf

マニュアル
PDF[Z210-E1-04] ZS-DSU (Ver 2.0) Smart Sensor (Data S...
... 2 3 4 5 Fitting 10 1 6 7 NC Pin No. 1 Pin No. 1 Signal name 4-4 ZS-DSU User’s Manual 8 9 Signal name NC SD(TXD) 2 2 RD(RXD) RD(RXD) 3 3 SD(TXD) RS(RTS) 4 4 NC CS(CTS) 5 5 SG(GND) NC 6 6 NC NC 7 7 RS(RTS) NC 8 8 CS(CTS) SG(GND) NC 9 9 NC 10 Section 4 RS-232C Input/Output Setting the Communication Specifications Set the RS-232C communications specifications. Match the communication specifications of the ZS-DSU to ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z210-e1-04_zs-dsu.pdf

マニュアル
PDFz239-e1-04_v600-ca5d0_.pdf
... ID Controller. 26 RFID System Operation Manual Section 2 Installation and Wiring RS-232C Port ■ Pin Arrangement Abbre- Signal direction viation Input Output Pin No. Signal name • Pin Arrangement 5 SG --- --- 2 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z239-e1-04_v600-ca5d0_.pdf

マニュアル
PDF[Z417-E1-02] D6FZ-FGX21, D6FZ Series Air Flow Stat...
... product drop or subject it to a shock, which may cause its damage or malfunction. Use screws to secure the product when mounting it on the wall. Stop using the product if it has been applied with a strong impact. ・ When inserting or removing an ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z417-e1-02_d6fz.pdf

PDF制御盤ソリューション導入ガイド
...単に移動可能。 <商品情報> ピタットチューブ株式会社西日本セフティデンキ電話 052-772-5000 ■ご購入はHPへ http://www.nishinihon-sd.co.jp マークチューブは記名板と同じプリンタで印刷できます。 <商品情報> キヤノン製ケーブルIDプリンタ Mk2600等 | 5 ねじ端子台...

https://www.fa.omron.co.jp/member/solution/panel/samc-019a-1.pdf

商品情報
NY5□□ サポートソフトウェア 更新内容詳細:サポートツール:オムロン
...ップデート 更新日:2021.8.2 新規機能 Windows10モデルのFirmwareです。 Ver.1.21.01 アップデート 更新日:2019.7.8 新規機能 仮想SDメモリカードに関するシステム定義変数の追加 AC_StepProgram命令の仕様拡張 Ver.1.18.04 アップデート 更新日:2019.1.15 機能改善 内部ソフ...

https://www.fa.omron.co.jp/product/tool/ipc-machine-controller/history.htm

NB-Designer ダウンロード:サポートツール:オムロン
...えてしまうことがある問題を改善しました。 PT拡張プロパティ設定で操作ログストレージ設定の記憶装置としてSD Cardが表示されることがある問題を改善しました。 NB-Designer Ver.1.44 (2017.04.10) 新規機能 LS産電製XECシリーズとの接続に対応し...

https://www.fa.omron.co.jp/member/product/tool/26/nb-designer/index.htm

商品情報
規格認証/適合状況一覧(形式別) | オムロン制御機器
...非適合 N/A : 非該当または対象外 形式 認証規格 UL認証 CSA認証 CEマーキング適合 CCC認証 船舶規格 G2R-1-SD DC24 Yes Yes Yes N/A Yes Yes : 取得または適合 No : 未取得または非適合 N/A : 非該当または対象外 ページ先頭へ戻る...

https://www.fa.omron.co.jp/product/certification/search/certification/?keyword=G2R-1-SD DC24

商品情報
規格認証/適合状況一覧(形式別) | オムロン制御機器
...非適合 N/A : 非該当または対象外 形式 認証規格 UL認証 CSA認証 CEマーキング適合 CCC認証 船舶規格 G2R-1-SD DC5 Yes Yes Yes N/A Yes Yes : 取得または適合 No : 未取得または非適合 N/A : 非該当または対象外 ページ先頭へ戻る...

https://www.fa.omron.co.jp/product/certification/search/certification/?keyword=G2R-1-SD DC5

商品情報
電力量モニタ&ロガー KM-D1(2020年9月1日発売) | オムロン制御機器
...ら分岐した単相2線式の計算 注.回路ごとにCT容量(5/50A、100A、225A、400A、600A)を調べます。 録れる内部メモリにロギングでき、SDカードやオンラインで簡単収集 計測データは内部メモリにCSVファイルで格納され、SD...

https://www.fa.omron.co.jp/product/promotion/km/

商品情報
NX-SL5 特設ページ | オムロン制御機器
...セーフティユニットリストア機能 作成済みのプログラムや設定情報は通信コントロールユニットに搭載されたSDカードへの保存が可能です。 セーフティCPUユニットの交換が必要になった場合にも、SDカードを用いることで新しい...