ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 3081 件が検索されました。(1061 - 1080件を表示)
カタログ
PDF[Q361-E1-01] V400-R2 Series Catalog
...Low contrast Distortion Dots 1 Distance Variations There are two models in the lineup to let you select the field of view or installation distance that is best for 93 the equipment type. Both models are the same size, ...

https://www.fa.omron.co.jp/data_pdf/cat/v400-r2_q361-e1_1_1_csm1129201.pdf

カタログ
PDF5-Megapixel C-Mount Code Reader
...strobe lighting. Strobe lights are triggered using Output 3 on the M12 IO connector through a flying leads cable. Omron also offers a line of Smart Lights that can be used in continuous or strobed mode. NERLITE Smart Series Lights have a built-in strobe controller, ...

https://www.fa.omron.co.jp/data_pdf/cat/v440-f_q342-e-03 (sp124a-en-0523).pdf

カタログ
PDFLaser-type Bar Code Reader V500 - R2 Series
.... Raster scanning enables reading Bar Codes even if they are partially dirty or missing. Dirt Wear Blurring Shiny background Inconsistent background Dots Resists Ambient Light Interference Operation is possible with ambient illumination of up to 80,000 lx (sunlight), ...

https://www.fa.omron.co.jp/data_pdf/cat/v500-r2_q360-e1_2_1_csm1129192.pdf

カタログ
PDFRFID System (Conforms to SEMI standard, Electromag...
... device or take other suitable methods to clear unwanted signals. Startup Precaution • Never turn OFF the power supply while the CIDRW Controller is starting, including when power is turned ON, when the mode is changed, or when the CIDRW Controller is being reset. Doing ...

https://www.fa.omron.co.jp/data_pdf/cat/v640_series_ds_e_11_1_csm1356.pdf

カタログ
PDFRFID System V680 Series RFID Systems with ISO/IEC ...
... before using it. 6. The DC power supply must be within the specified rating (24 VDC +10%/−15%). 7. Do not reverse the power supply connection. 8. Do not insert water, wire, etc., into any of the gaps in the case. Doing ...

https://www.fa.omron.co.jp/data_pdf/cat/v680 series_q267-e1_1_23_csm1003322.pdf

カタログ
PDFRFID System V680 Series Global Standard of Manufac...
..., such as accidentally mounted, automatic mold checks performed mechanical flags, enables the build-out of maintenance-free before the molding process can prevent production of defects. systems with very few failures. 6 Massive System Variation We provide a wide variety of RFID components ...

https://www.fa.omron.co.jp/data_pdf/cat/v680_q266-e1_3_1_csm1001035.pdf

カタログ
PDFAuto-Focus Multi-Code Reader VHV5-F
... require manually adding tools, drawing individual search regions, and configuring parameters, Learn All Codes handles these tasks automatically. This reduces the time needed to create complex jobs from minutes to seconds Result of Learn • Tools arranged in reading order • ROIs (Regions of Interest) ...

https://www.fa.omron.co.jp/data_pdf/cat/vhv5-f_q358-e_1_1_csm1132108.pdf

カタログ
PDF[P099-E1-04] SYSMAC-XR006 Vibration Suppression Li...
...: 120 ms Vibration settling time: 100 ms 20 x 20 = 400 chips per pallet Resonance frequency of pallet: 30 Hz Vision inspection Handling time per pallet: 220 ms per chip x 400 chips = 88 s Application The XY stage moves a pallet ...

https://www.fa.omron.co.jp/data_pdf/cat/vibration_suppression_library_p099-e1_2_4_csm1047444.pdf

カタログ
PDFTwo-circuit Limit Switches General-purpose Switche...
... remove the two screws to mount the switch in any of the four possible orientations. If changing the direction of the head, pay attention to the orientation of the operation plunger. Roller Lever Bolt Set Position Marker Plate Set the indicator needle ...

https://www.fa.omron.co.jp/data_pdf/cat/wl-n_wlg_c151-e1_4_4_csm1057870.pdf

カタログ
PDFTwo-circuit Limit Switch WL CSM_WL_DS_E_19_8
...actuator) to increase resistance to oils, chemicals, and weather. Cables attached. Uses an airtight built-in switch. The case cover and box interior are molded from epoxy resin to increase the seal. The cover cannot be removed. The SC connector can be removed, ...

https://www.fa.omron.co.jp/data_pdf/cat/wl_ds_e_19_8_csm582.pdf

カタログ
PDFRound Water-resistant Connectors (M12 Threads)
... colors correspond to the pin clamp numbers that are identical to the connector pin numbers. Insertion Pin Block Pin Clamp Key groove Key groove Key XS2C use XS2G use 6±0.5 • Tentatively insert the pins to the pin block holes ...

https://www.fa.omron.co.jp/data_pdf/cat/xs2_ds_e_12_10_csm1342.pdf

カタログ
PDFRound Water-resistant Connectors (M12 Smartclick)
... core wire end has been pushed lightly into the IDC cover by tweezers etc, cable removal becomes easy. completion position Note 1. When the operation has completed, mark of cap comes into the square of the indicator formed into a mold cover ( ), ...

https://www.fa.omron.co.jp/data_pdf/cat/xs5_ds_e_14_6_csm1340.pdf

カタログ
PDFRound Oil-resistant Connectors (M12 Smartclick)
...humidity can cause bad connections and damage through corrosion, leading to degraded performance, therefore do not use these products in such environments. • Do not pull on the Connectors or cables with excessive force. • Do not step on or place any objects on the Connectors. Doing ...

https://www.fa.omron.co.jp/data_pdf/cat/xs5_next_series_ds_e_3_1_csm1061504.pdf

カタログ
PDFSensor connection can be completed...
...For 5 to 8-mm dia., just remove the tabbed, waterproof bushing. *A 5-mm dia. cable connects with or without the bushing. Anyone... Visual confirmation is possible. ...with no torque management The tightened ti position is clear, ...

https://www.fa.omron.co.jp/data_pdf/cat/xs5c_g_g078-e1_2_2_csm1011236.pdf

カタログ
PDFConnector-Terminal Block Conversion Units for Gene...
...Precautions for Correct Use Wiring Precautions • Do not perform wiring work, remove connectors, or connect connectors while power is being supplied. Electric shock or damage to the device may result. • Double-check all wiring before turning ON the power supply. • After wiring, route the cable ...

https://www.fa.omron.co.jp/data_pdf/cat/xw2r_ds_e_2_5_csm1012297.pdf

カタログ
PDF[G083-E1-04] XW2Z Data Sheet
... icing) *3 Note: This cable is for fixed parts. Do not use it for moving parts. *1. Contact resistance for the Connector. *2. Dielectric strength for the Connector. *3. However, when bending the cable to perform wiring, maintenance, and other work, do ...

https://www.fa.omron.co.jp/data_pdf/cat/xw2z-l_g083-e1_2_3_csm1017577.pdf

カタログ
PDFConnecting Cables for Connector-Terminal Block Con...
... icing) *3 Note: This cable is for fixed parts. Do not use it for moving parts. *1. Contact resistance for the Connector. *2. Dielectric strength for the Connector. *3. However, when bending the cable to perform wiring, maintenance, and other work, do ...

https://www.fa.omron.co.jp/data_pdf/cat/xw2z_ds_e_5_7_csm1353.pdf

カタログ
PDFConnector Terminal Boxes XW3D CSM_XW3D_DS_E_3_5
...disconnecting connectors. • Do not touch the mating surface of the connectors with wet hands. • Wipe away any water around the connectors. • Do not allow metal scraps or dust to enter the mating section. Cable Lead Polarity • Wire as in the wiring diagram ...

https://www.fa.omron.co.jp/data_pdf/cat/xw3d_ds_e_3_5_csm1341.pdf

カタログ
PDFAccessories Y92@ CSM_Y92__DS_E_7_4
... Cover) Shielded Models M30 Shielded Models Polyacetal resin M12 Unshielded Models M30 × 1.5 B C Applicable Sensor diameter [A Sputter Protective Covers cannot be used with a Capactive Proximity Sensor.] The cover uses Fluororesin, ...

https://www.fa.omron.co.jp/data_pdf/cat/y92__ds_e_7_4_csm470.pdf

カタログ
PDFSmart Sensor ZG2 Series 2D Measurement Sensor
.... 12x the conventional sensitivity 2.5x 10x the conventional inclination tolerance the conventional speed Measurement can be performed at a stable level in a large amount of ambient light, even on objects that do not reflect light ...

https://www.fa.omron.co.jp/data_pdf/cat/zg2_q167-e1_6_8_csm2085.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。