全 414 件が検索されました。(81 - 100件を表示)
- カタログ
...a 40-ms OFF-delay timer will start. E2C-AK4A 10 to 30 VDC Black NPN opencollector output OFF-delay operation terminal* 12 to 24 VDC Line 6 5 6 5 4 3 1 2 Tc Ta Tb 100 to 240 VAC Relay output Line 4 3 Shield Line Brown Black Blue Applicable Socket: P2CF-08 7 8 1 2 PNP 0 V 12 to NPN Output 24 VDC output 10 to 30 VDC NPN opencollector output 0V Note: Characteristics will change if the cable length changes. Do not cut or extend the cable. 10 E2C/E2C-H Load Connections...
- カタログ
.... T Incident light No incident light T T L-ON ON OFF D-ON T ON OFF Incident light No incident light L-ON ON OFF D-ON ON OFF Ta Tb Ta Tb A timer value can be set after pressing button when a timer menu (other threshold MODE display than “ Incident level Use Passing time(ms or μs) or longer to set [ ]. Send a workpiece past the Fiber Unit. Displaying the Passing Time and Difference in Incident Levels. ”) is displayed. button to set the time. UP/DOWN (1 to 9999 ms in 1 ms steps; the initial ...
- カタログ
...E3JK-DR12 E3JK-DR13 E3JK-DR14 Operation Indicator (orange) Incident light Incident light No incident light No incident light Operation Indicator (orange) ON OFF Operate Reset Relay Output Tc-Ta Output Tc-...
- カタログ
... (Ta) D-ON (Ta) Photoelectric Sensor main circuit ON OFF ON OFF ON OFF Refer to page 6 for information on Sensors with timers (T). Power Source 1 No polarity 2 3 Tb 4 Tc 5 Ta Contact output (Built-in Relay: G6C) DC SSR Output Models Model Timing chart Output circuit 24 to 240 VAC 12 to 240 VDC Power Source 1 No polarity E3JM-10S4(T)(-G)-NN(-US) E3JM-R4S4(T)(-G)(-US) E3JM-DS70S4(T)(-G)(-US) Incident light No incident light Indicator (red) * L-ON (Ta) D-ON (Ta) 2 ON OFF L/ON...
- カタログ
...Incident light No incident light ON L-ON OFF ON D-ON OFF T T Incident light No incident light Ta ON L-ON OFF Ta ON D-ON OFF Tb Tb E3NX-CA Nomenclature Standard Models E3NX-CA11/CA41/CA6/CA8 NO/NC Button Used to set the external output polarity. When NO (normally open) is set, the output is ON when a workpiece is in the sensing area. When NC (normally closed) is set, the output is ON when a workpiece is not in the sensing area. NO/NC Indicator (Orange) Indicates the current NO/NC setting status....
- カタログ
...Multi-sensing technology Flow rate Uses the "Thermal flow rate measurement algorithm". The sensor calculates first the flow velocity by measuring how fast the fluid cools the heated temperature measuring element Ta, and then the flow rate based on the pipe diameter. The temperature measuring element ...
- カタログ
... Images are saved even during measurements *2. All images can be saved under the following conditions: • One 0.4 Mpix camera • Measurement time of 30 ms • JPEG file • Images can be saved continuously for approx. 380 days when a 3 ...
- カタログ
...X-Large > 30 *1 4 cores Clockspeed 4 GHz 8 GHz 12 GHZ 16 GHz Virtual RAM 8 GB 16 GB 24 GB 32 GB Virtual Disk 512 GB FLOW Software Version 1 TB Minimum FLOW Core 4.0 *1. Contact your local OMRON representative for fleets larger than 100. Note: The PC/IPC/Server is supplied by the user. Charging Station Maximum Current Input current: 25 A Output current: 120 A (nominal) *1 Input Voltage 3-phase 200 to 240 VAC, 50/60 Hz (Delta/Wye) 380 to 415 VAC, 50/60 Hz (Wye only) Output Voltage 40 to ...
- カタログ
... the open-phase element, but the operating value of the overload element may vary. 3 K2CM Connections Voltage Reverse-phase Detection Models Manual Operation Low-voltage Circuit (Highcapacity Motor) Terminal Arrangement 200 VAC 50/60Hz R Ta Tc ...
- カタログ
...24 VDC Protection IP40 IP65 (Oil-proof type) Ordering Information Plateau Head Indicators Degree of Protection: IP40 Flange Color: Black Type Plateau Head Indicator Flange Color: Metallic LED voltage Model 5 VDC M3U-...
- カタログ
... nominal Recharge Time 19.6 minutes (from 20% to 80%) *1 Charge Cycles Approximately 3000 cycles *2 *3 Charging Method Automatic or manual Ambient Operating Temperature 5 to 40°C 4 cores 512 GB 32 GB 1 ...
- カタログ
...AWG28 to 16 8 to 10 mm 2.0 mm2 9 to 10 mm *1. Secure wires to the screwless clamping terminal block. Refer to the Securing Wires in the USER'S MANUAL for how to secure wires. *2. With the NX-TB@@@1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wire. Conductor length (stripping length)
If more than 2 A will flow on the wires, use plated wires or use ferrules. 41 NX-AD/DA Dimensions (Unit/mm) Screwless Clamping Terminal Block Type 12 mm Width 14.1 12.... - カタログ
... mm2 AWG28 to 16 8 to 10 mm 2.0 mm2 9 to 10 mm *1 Secure wires to the screwless clamping terminal block. Refer to the Securing Wires in the USER'S MANUAL for how to secure wires. *2 With the NX-TB@@@1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wire. Conductor length (stripping length)
If more than 2 A will flow on the wires, use plated wires or use ferrules. 11 NX-CIF NX-CIF210 (B) (C) (D) (E) (C) (A) (B) (F) (G) (I) Letter (... - カタログ
...9 to 10 mm Not Possible Possible Possible *2 *1 Secure wires to the screwless clamping terminal block. Refer to the Securing Wires in the USER'S MANUAL (Cat. No. Z395) for how to secure wires. *2 With the NX-...
- カタログ
...*2 Conductor length (stripping length) 8 to 10 mm 9 to 10 mm *1. Secure wires to the screwless clamping terminal block. Refer to the Securing Wires in the USER'S MANUAL for how to secure wires. *2. With the NX-...
- カタログ
... mm2 AWG28 to 16 8 to 10 mm 2.0 mm2 9 to 10 mm *1 Secure wires to the screwless clamping terminal block. Refer to the Securing Wires in the USER'S MANUAL for how to secure wires. *2 With the NX-TB@@@1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wire. Conductor length (stripping length)
If more than 2 A will flow on the wires, use plated wires or use ferrules. 11 NX-EC0/ECS/PG0 MIL Connector Type (1 Connector with 34 terminals) 30 mm Width (... - カタログ
... mm2 AWG28 to 16 8 to 10 mm 2.0 mm2 9 to 10 mm *1 Secure wires to the screwless clamping terminal block. Refer to the Securing Wires in the USER'S MANUAL for how to secure wires. *2 With the NX-TB@@@1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wire. Conductor length (stripping length)
If more than 2 A will flow on the wires, use plated wires or use ferrules. 9 NX-ECC Dimensions (Unit: mm) EtherCAT Coupler Unit z EtherCAT Coupler Unit Only 48.1... - カタログ
...Possible Possible 9 to 10 mm 2.0 mm2 *2 *2 *1. Secure wires to the screwless clamping terminal block. Refer to the Securing Wires in the USER'S MANUAL for how to secure wires. *2. With the NX-TB@@@1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wire. Ground terminals --- Possible Possible Conductor length (stripping length)
If more than 2 A will flow on the wires, use plated wires or use ferrules. 12 NX-EIC Dimensions (Unit: mm) z EtherCAT Coupler Unit Only 48.1 46 0.55 1.... - カタログ
...Not possible Possible Possible*2 *1. Secure wires to the screwless clamping terminal block. Refer to NX-series Analog I/O Units User’s Manual for High-speed Analog Input Units (W592) for how to secure wires. *2. With the NX-...
- カタログ
...AWG28 to 16 8 to 10 mm 2.0 mm2 9 to 10 mm *1. Secure wires to the screwless clamping terminal block. Refer to the Securing Wires in the USER'S MANUAL for how to secure wires. *2. With the NX-TB@@@1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wire. Conductor length (stripping length)
If more than 2 A will flow on the wires, use plated wires or use ferrules. 74 NX-ID/IA/OD/OC/MD M3 Screw Terminal Block Type 30 mm Width (A) (B) (C)...