ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索

検索結果を絞り込む


全文検索:全 3076 件が検索されました。(881 - 900件を表示)
カタログ
PDFCompact Ultrasonic Sensor E4E2 CSM_E4E2_DS_E_2_4
... E4E2 needs a maximum of 100 ms to be ready to operate after the E4E2 is turned ON. If power is supplied to the E4E2 and the load independently, be sure to turn ON the E4E2 first. • Installation Mounting Mount the Emitter and Receiver ...

https://www.fa.omron.co.jp/data_pdf/cat/e4e2_ds_e_2_4_csm1726.pdf

カタログ
PDF[-] E4PA-N Data Sheet
...safety standards, refer to your OMRON website. Application Examples Detecting slackness in sheet materials Detecting liquid levels Remotely detecting LCD wafers Detecting dies Features  High-precision detection with a wide range of measurements.  The Sensor is ultrasonic, ...

https://www.fa.omron.co.jp/data_pdf/cat/e4pa-n_ds_e_5_4_csm1404.pdf

カタログ
PDF[-] E5C2 Data Sheet
... the E5C2 and the load, the supply voltage of the power supply may vary greatly when the load is open or closed if the capacity of the power supply is not large enough. Make sure that the capacity of the power supply is large enough ...

https://www.fa.omron.co.jp/data_pdf/cat/e5c2_ds_e_7_2_csm214.pdf

カタログ
PDF[H172-E1-04] E5CB Data Sheet
... Terminal Cover: E53-COV19 (sold separately) • USB-Serial Conversion Cable: E58-CIFQ2 (sold separately) • Recommended panel thickness is 1 to 5 mm. • Do not vertically mount Controllers side by side. (Allow mounting clearance between the Controllers.) • To install the Controller ...

https://www.fa.omron.co.jp/data_pdf/cat/e5cb_h172-e1_8_6_csm2667.pdf

カタログ
PDF[-] E5CS Data Sheet
...45 3 45 4.5 16.3 9 2 1 11 10 6 6.2 8.7 Note: The Y92A-48G Finger Safe Terminal Cover is also available. Note: Do not use any other types of Sockets. Doing so will adversely affect the accuracy. Applicable Thermistors Hard Protective Cover Use Element Interchangeable Thermistors (E52-THE5A, E52THE6D, and E52-THE6F) to connect to the E5CS-@GU. For details on Sensors, refer to E52. The Y92A-48B Hard Protective Cover is available for the following applications. • To protect the set from dust and dirt. • To prevent the panel from being accidentally touched ...

https://www.fa.omron.co.jp/data_pdf/cat/e5cs_ds_e_5_3_csm211.pdf

カタログ
PDF[H162-E1-09] E5L Data Sheet
.... 2. The setting protection indicator ( ) and set value indicator ("SV") will be continued even when settings are protected, except when a memory error occurs. 7 E5L Safety Precautions CAUTION Do not touch the terminals while power is being supplied. Doing ...

https://www.fa.omron.co.jp/data_pdf/cat/e5l_h162-e1_2_12_csm2072.pdf

カタログ
PDF[-] E63-WF Data Sheet
...3 Brown 12 to 24 V 4 1 2 Black (phase A) White (phase B) Orange (phase Z) Rotary Encoder Blue (0 V) Shield Note 1: Used only to reset the counter using phase Z. When doing so, set the phase ZZ switch to Z and use a Rotary Encoder with an Open-collector Output. 2: When using phase Z, be sure that the width of phase Z is the same as or wider than the width of phase A. 3. Use one of the following Rotary Encoders: E6A2-CW3C, E6A2-CW5C, E6A2-CWZ3C, E6B2CWZ6C, E6H-CWZ6C, E6C2-CWZ6C, or ...

https://www.fa.omron.co.jp/data_pdf/cat/e63-wf_ds_e_4_4_csm489.pdf

カタログ
PDF[-] E6B2-C Data Sheet
.... Do not use the product in excess of the rated voltage. Applying voltages beyond the rated voltage range may cause the product to break or burn. 2. Avoid wiring the product's cables parallel to power lines or high voltage lines. Doing ...

https://www.fa.omron.co.jp/data_pdf/cat/e6b2-c_ds_e_6_3_csm491.pdf

カタログ
PDF[-] E6C2-C Data Sheet
... product to break or burn; During operating, if applying voltages below the rated voltage range may cause the output to shut down. At that time, please restart the power. (2) Avoid wiring the product's cables parallel to power lines or highvoltage lines. Doing ...

https://www.fa.omron.co.jp/data_pdf/cat/e6c2-c_ds_e_6_4_csm493.pdf

カタログ
PDF[-] E6C3-A Data Sheet
... 20004 20003 00003 20004 00002 20003 Converts gray code to binary (CIO 200). Sets the unused bits (10 to 15 bits) of CIO 200 to unused (always 0). 20300 20301 20302 20002 Resolution is 720, so 152 is subtracted. No subtraction would be necessary for resolution of 256 or 1,024. If resolution was 360, 76 would be subtracted. TABLE COMPARE Instruction BCMP(68) If the Encoder value (CIO 202) 202 is within a range in the DM6200 conversion table set in DM 203 6200 to DM 6231, the corresponding bit in CIO 203 will turn ON. 01000 SUB(...

https://www.fa.omron.co.jp/data_pdf/cat/e6c3-a_ds_e_8_4_csm494.pdf

カタログ
PDF[-] E6J-C Data Sheet
... and response frequency. There is a tendency that the residual voltage increases or a waved distortion occurs, due to changes in the cable resistance and the capacity between cables. • Do not lay the cables in parallel with high-voltage lines or power lines. Doing ...

https://www.fa.omron.co.jp/data_pdf/cat/e6j-c_ds_e_4_3_csm674.pdf

カタログ
PDFIoT Status Monitoring Amplifier
... power supply before connecting or disconnecting wires. Do not attempt to disassemble, repair, or modify the product in any way. When disposing of the product, treat it as industrial waste. Do not use the Sensor in water, rain, or outdoors. Process the unwired terminals ...

https://www.fa.omron.co.jp/data_pdf/cat/e9nc-aa_va_e474-e1_2_2_csm1065027.pdf

カタログ
PDFContact-Type Smart Sensor E9NC-T
...Safety Precautions Be sure to read the precautions for E9NC-T in the website at: http://www.ia.omron.com/. Sensor Heads WARNING Do not forcibly bend or pull the cables. Do not put a heavy object on them or heat them. Doing ...

https://www.fa.omron.co.jp/data_pdf/cat/e9nc-t_e434-e1_10_4_csm1012458.pdf

カタログ
PDF[-] EE-SA701/SA801 Data Sheet
... emitter (GaAs infrared LED) and receiver (Si photo IC) are positioned across from each other inside the sensor and light is received when there is no sensing object. When the sensing object presses the actuator, the light path between the emitter and receiver is broken ...

https://www.fa.omron.co.jp/data_pdf/cat/ee-sa701_801_ds_e_4_3_csm662.pdf

カタログ
PDFLong-distance Through-beam Photomicrosensor
...Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes.  Axis Adjustment (1)Tentatively mount the emitter and receiver ...

https://www.fa.omron.co.jp/data_pdf/cat/ee-spw311_411_ds_e_6_3_csm472.pdf

カタログ
PDFPre-wired Photomicrosensor with Amplifier and Cabl...
...3 3 Slit C 3 0.5 Slit D 3 1 Note: These are pressure sensitive adhesive-type stickers. Peel off the seal and stick it on the lens. Optical Axis Adjustment (1)Set the Sensor so that the center of the lens in the emitter and receiver form one line. (2)Having checked that the Sensor is correctly wired, turn ON the power. The operation indicator on the amplifier of the emitter will light. Check to make sure the light goes ON and OFF when an opaque object is moved in and out between the emitter and receiver. (3)...

https://www.fa.omron.co.jp/data_pdf/cat/ee-spw321_421_ds_e_5_4_csm473.pdf

カタログ
PDFUltra-compact Pre-wired Photomicrosensor (Non-modu...
... to the Safety Precautions on page 5. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Features Mount Using M2 or M3 Screws The EE-SX95 can be mounted using M2 or M3 screws, ...

https://www.fa.omron.co.jp/data_pdf/cat/ee-sx95_e435-e1_3_6_csm1012815.pdf

カタログ
PDF[-] EE-SX97 Data Sheet
...Built-in Thermal Shutdown Circuit Control output 2 on models with NPN outputs is protected from output overcurrents by a built-in thermal shutdown circuit. Display Two Outputs: Light-ON and Dark-ON All models provide both a light-ON and dark-ON output ...

https://www.fa.omron.co.jp/data_pdf/cat/ee-sx97_ds_e_1_4_csm2587.pdf

カタログ
PDF[-] EE-SY671/SY672 Data Sheet
...Cable Extension • When extending the cable, use an extension cable with conductors having a total cross-section area of 0.3 mm2. The total cable length must be less than 10 m. z Installation The photomicrosensor is built into the device being used and ...

https://www.fa.omron.co.jp/data_pdf/cat/ee-sy671_672_ds_e_6_4_csm486.pdf

カタログ
PDF[-] EJ1 Data Sheet (Produced in or before November...
....2 kbps Set to ON to display the output status on the operation indicators. OFF: The operation status is displayed (PWR, RUN, ERR, and ALM). ON: The output status is displayed (outputs 1, 2, 3, and 4). Note: Normally keep this pin set to OFF ...

https://www.fa.omron.co.jp/data_pdf/cat/ej1_ds_e_12_5_csm222.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。