全 55143 件が検索されました。(5481 - 5500件を表示)

  • カタログ

    ... are also susceptible to the influences of ambient light so are difficult to measure using conventional laser measurement sensors. The ZG2 solves these problems because it is supersensitive and significantly reduces ambient noise. It also has an APS function to automatically tune parameters such as a receiver’...

  • カタログ

    ...voltage 24 VDC Current consumption 900 mA max. (input from included AC adapter) Discharge voltage ±7 kV Discharge method Variable DC Airflow (m3/min.) 1.4 to 2.3 m3/min (typical) Ionization time *2 1.2 ...

  • カタログ

    ...-FW053 Power supply voltage 24 VDC±10%, Ripple (p-p): 10% Current consumption 0.9 A max. 1.2 A max. 3.0 A max. Discharge voltage ±7.5 kV Discharge method Variable DC Ionization time * 1.5 s 1s Ion balance * ±10 V max. Amount of ozone generated 0.01 ppm (Measured at a distance of 50 mm from air outlet) Indicators Power (green), Fan running (green), Cleaning (yellow), Alarm (red) Main functions Ion balance adjustment (Automatic and manual) External output Photo MOS relay output (NPN or PNP) (for both cleaning and alarm • Applied voltage: 30 VDC max., ...

  • カタログ

    ...refer to the Technical Guide on your OMRON website. Precaution for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. For details on information such as the usage precautions, refer to the ZJ-SD Series Smart Electrostatic Sensor User’...

  • カタログ

    ...refer to the Technical Guide on your OMRON website. Precaution for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. For details on information such as the usage precautions, refer to the ZJ-SD Series Smart Electrostatic Sensor User’...

  • カタログ

    ... Clean Units ZN-A2502D Power supply voltage 24 VDC ±10%, Ripple (p-p): 10% max. Current consumption 300 mA max Discharge voltage ±7 kV max Discharge method Variable DC discharge Static electricity removal time (typical) *1 5 ...

  • カタログ

    ...Laminar Airflow Design The smaller fan section and the unique ventilation construction design provides a more uniform laminar airflow. Uniform air is provided over a wide area. ZN-A2502 ZN-A4105 Air Speed Distribution Air Speed Distribution 200 0.8 m/...

  • カタログ

    ... Hz/60 Hz Maximum number of times clamped 5,000 Clamp core inner diameter 23 Applicable circuit voltage 480 VAC max. Display 7-segment LCD with 4 digits on 1 row, supplemental information indicators, and CHARGE indicator Logging interval 1 ...

  • カタログ

    ...i im n m ou Easy and Quick "Checking Power" at the Worksite I do not want to stop the machine to just check power. Do you have the concerns about power measurement? It's troublesome to install the measuring equipment, when you want to check power. It takes time to collect data. Logging unit (actual size) For more information Power is indicated based on CT(current) What you do is just connecting CT. There is no need for wiring for voltage measurement. Battery-powered, Fixed by Magnet and Ultra-thin External power source is not necessary. Easy to mount ...

  • カタログ

    ... to three Branch-type CT Units to the Branch Cable. Be sure, however, not to connect a CT of different rated current. Correct measurement will be blocked. 1 ZN-CTX/-CTM Optional Appearance Product name Model Mounting magnet ZN9-EM01-...

  • カタログ

    ... OMRON website. Refer to the Safety Precautions on page 2. Ordering Information Main unit Stations Appearance Item Model Station Power supply ZN-KMX21-A DC cable Options Appearance Item DC cable (ZN9-ED01-...

  • カタログ

    ...Operation verification Operation/maintenance Time/effort saved ZP-L Sensing performance delivering stable detection with initial configuration left intact Black polished surface ( painted car body surface ) PWB Black rubber P.4 SUS 2B ( stainless steel ) ZP-L’...

  • カタログ

    ...) Beam shape Line beam Beam diameter *1 2.2mm × 45 µm 1.0mm × 30 µm 16 × 0.3 mm (at 500 mm) 40 × 1.5 mm (at 1,500 mm) Linearity *2 ±0.2% F.S. ±0.1% F.S. ±0.07% F.S. (250 to 750 mm) ±0.1% F.S. (750 to 950 mm) ±0.2% F....

  • カタログ

    ... Sensing Fu Very High-performance Sensors that Support Core Quality from Very Long-range to Extremely Precise Measurements Range of models with measuring center distance of 20 to 1,500 mm. Achieves maximum resolution of 0.25 m. Maximum response speed of 110 ...

  • カタログ

    ...[E607-E1-01] ZUV Series ZUV-C40H/C40H-D Catalog S mar t Curing S ys tem ZU V S eries Anywhere in the world OMRON's "reliability" as the reason for choice OMRON was among the first in the industry to focus on the LED light source which causes less thermal damage and has less running costs than conventional lamps, and has been offering UV LED curing systems for 17 years (as of 2022). The long-time best seller ZUV Series has been meeting the UV curing needs with the ever-increasing variety of lenses and heads....

  • カタログ

    ... cooling (no fan) Power supply voltage 100 to 240 V AC±10% 50/60 Hz (In the case of using AC adapter) *1 *2 19 V DC±5% *3 ZUV-C30H (Multi-function model) Irradiation power (0% to 100%), Irradiation time (999.9 ...

  • カタログ

    ... other specifications differ among models. Refer to the Specifications for details. Please ask Omron sales representative for angle characteristic. Confocal Fiber Displacement Sensor ZW-8000/7000/5000 Series 4 Unsurpassed stable in-line measurement The ZW Series has continued to evolve, meeting the customer’...

  • カタログ

    ...ZW-5000T Series Other EtherCAT Slaves Sensor Head ZW-SQ Series Calibration ROM (included with Sensor Head) EtherCAT Cable (RJ45/RJ45) EtherCAT Cable (RJ45/RJ45) EtherCAT Cable (Select the cable that matches the Slave'...

  • カタログ

    ....8 mm 4 mm ZX-EV04T *2 *3 Heat-resistant, cylindrical M12 x 22 mm 2 mm ZX-EM02HT *4 *1: For an average count of 4,096. *2: Models with Protective Spiral Tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01T-...

  • カタログ

    ...area. Maximum 500-mm area Accurate! 10-μm by non-contact method ZX-GT is the only sensor with the ability to measure and locate position to an accuracy of 10 μm without contact. Unlike conventional through-beam laser sensors, the ZX-GT’...