マニュアル
PDFw368-e1-10_cs1w-p____cj1w-p___.pdf
... specific to each Unit, refer to the explanations in SECTION 2 Individual Unit Descriptions for CS Series. Item Unit classification Specification CS-series Special I/O Unit Structure Dimensions Backplane-mounted, single slot size 35 × 130 × 126 mm (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w368-e1-10_cs1w-p____cj1w-p___.pdf

マニュアル
PDF[W371-E1-03] SYSMAC CPM2B Programmable Controller ...
... V DC) Expansion I/O Boards With relay With transistor outputs outputs CPM2B32C@DT1-D12 CPM2B-32EDR CPM2B-40EDR 12 V DC (Allowable range: 10.8 to 13.2 V DC) Supplied from CPU Board. 20 W max. 20 A max. CPM2B-32EDT CPM2B-32ED1T CPM2B-64EDT ----- Insulation resistance 20 MΩ min. (at 500 V DC) between the external DC terminals and non-current carrying metal parts Dielectric strength 1,000 V AC 50/60 Hz for 1 min between the external DC terminals and non-current carrying metal parts Noise immunity Conforms to IEC6100-4-4; 2 kV (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w371-e1-03_cpm2b.pdf

マニュアル
PDFw372-e1-16_cx-processtool.pdf
...Parameter Parameter ITEM Contents 004 Operation cycle (s) 008 012 023 024 High/Low alarm Hysteresis set value Local SP set value SP set method (Initial setting) 0: Local, 1: Remote/Local R: Read, W: Write, R/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w372-e1-16_cx-processtool.pdf

マニュアル
PDFw376-e1-08_cs1w_nc.pdf
... max. at 24 VDC 24 VDC 24 VDC NC433: 220 mA max. at NC233: 120 mA max. at NC133: 60 mA max. at 5 VDC 5 VDC 5 VDC External dimensions 130 (H) × 35 (W) × 101 (D) (all models) Weight 250 g max. 250 g max. 300 g max. Safety standards UL, CSA, EC (EMC Directive) Note Specifications not listed above conform to CS Series general specifications. 9 Section 1-5 Specifications 1-5-2 Performance Specifications Item Applicable PLC models I/O requirements Words Slots Controlled driver Control Control system Number of control axes Control unit...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w376-e1-08_cs1w_nc.pdf

マニュアル
PDFw378-e1-02_cs1w-hio_hcp_hca_v1.pdf
... installation and remains within the specified conditions during the life of the system. 5 Application Precautions !WARNING Always heed these precautions. Failure to abide by the following precautions could lead to serious or possibly fatal injury. • Always connect to a ground of 100 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w378-e1-02_cs1w-hio_hcp_hca_v1.pdf

マニュアル
PDFw380-e1-10_cs1w_cj1w-drm.pdf
...power supply). DRT1-OD16TA DRT1-OD16TA-1 DRT1-MD16T DRT1-MD16T-1 DRT1-MD16TA DRT1-MD16TA-1 DRT1-ID32ML DRT1-ID32ML-1 DRT1-OD32ML DRT1-OD32ML-1 DRT1-MD32ML Compact (35 x 60 x 80 mm (W x D x H)) Connects to a Relay Terminal through a MIL cable. Does not need a separate power supply for internal circuits (uses the communications power supply). DRT1-MD32ML-1 DRT1-ID16X DRT1-ID16X-1 DRT1-OD16X DRT1-OD16X-1 Compact (85 x 50 x 40 mm (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w380-e1-10_cs1w_cj1w-drm.pdf

マニュアル
PDF[W381-E1-03] 3G8F7-DRM21-E DeviceNet™ PCI Board Op...
... details on connection methods and grounding. 7 Section 1-6 Specifications 1-6 1-6-1 Specifications DeviceNet PCI Board General Specifications Item Dimensions Operating voltage range Current consumption Specifications 119.9 × 106.7 mm (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w381-e1-03_3g8f7-drm21-e.pdf

マニュアル
PDFw384-e1-01_cs1w-hio01_hcp22_hca22.pdf
...safety, programming macro function, subroutines, preparing data in data areas, pulse frequency, pulse outputs, , , controlling, , target value comparison, TIM/CNT numbers, Timer/Counter Area , timer/counter numbers, timers, conditions when reset, , , reading PV, TR Area, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w384-e1-01_cs1w-hio01_hcp22_hca22.pdf

マニュアル
PDF[W395-E1-09] CJ1M-CPU21/CPU22/CPU23 CPU Units Oper...
...-series or UE-series Servomotor Note When using a One-axis Relay Unit (connected to pulse output 0), general-purpose outputs 2 and 3 (OUT2 and OUT3) and PWM(891) output 1 (OUT5) cannot be used. 30 Wiring Section 3-2 OMRON OMNUC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w395-e1-09_cj.pdf

マニュアル
PDFw410-e1-01_cs1w_gpi01.pdf
..., LF, EOI, or user-set code. Max. data transfer size Max. number of connectors 512 bytes max. in a single reception or transmission 2 (See note.) Current consumption Dimensions 5 VDC, 330 mA 35 × 130 × 101 mm (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w410-e1-01_cs1w_gpi01.pdf

マニュアル
PDF[W419-E1-04] CS1W-MCH71 Motion Control Unit Operat...
...-1 System Configuration System Configuration Example The MC Unit is adopted a high-speed communication pathway to simplify its wiring. It makes it possible to have up to 30 axes for controls. Computer MCH71 Memory card Sensor/ Valve ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w419-e1-04_cs1w-mch71.pdf

マニュアル
PDFw430-e1-02_cs1d-etn21d.pdf
... operating temperature Ambient humidity 0 to 55°C 10% to 90% (with no condensation) Atmosphere Ambient storage temperature Must be free of corrosive gas. −20 to 75°C Weight Dimensions 200 g max. 35 × 130 × 101 mm (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w430-e1-02_cs1d-etn21d.pdf

マニュアル
PDFw433-e1-10_cx-position.pdf
... V) Stepping motor drivers Servomotor drivers Stepping motor drivers or Stepping motors Note Servomotor drivers or Servomotors Stepping motors Servomotors 1. Special cables are available to connect OMRON U-series Drivers, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w433-e1-10_cx-position.pdf

マニュアル
PDFw436-e1-12_cx-motion-ncf.pdf
...Windows 2000, XP, and Vista supported Ver. 1.91 Windows 2000, XP, Vista, and Windows 7 supported Improvements from Version 1.8 to Version 1.9 New Applicable Hardware Item Applicable Servo Drives Ver. 1.8 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w436-e1-12_cx-motion-ncf.pdf

マニュアル
PDF[W441-E1-03] CJ1M-CPU1[]-ETN CPU Units with Ethern...
...(according to JIS C0041) 0 to 55°C 10% to 90% (with no condensation) Must be free from corrosive gases. –20 to 75°C (excluding battery) Less than 100 Ω Mounted in a panel. 210 g max. 62 × 90 × 65 mm (W...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w441-e1-03_cj1m-cpu1.pdf

マニュアル
PDF[W452-E1-08] NSJ5, NSJ8, NSJ10, NSJ12, NSJW NSJ Co...
...stable output even if the power supply input is interrupted for 10 ms. The DC power supply must also have reinforced or double insulation. Rated power supply voltage: 24 VDC (Allowable range: 20.4 to 27.6 VDC) Capacity for NSJ12, NSJ10, or NSJ8: 30 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w452-e1-08_nsj_setup.pdf

マニュアル
PDF[W454-E1-04] GRT1-DRT DeviceNet™ Communications Un...
... to ON two times to backup the parameter data.) One open connector for DeviceNet, with screws The XWG4-05C4-TF-D Multi-drop Connector can be connected. Two terminals for I/O power supply Two terminals for Unit power supply 3W 80 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w454-e1-04_grt1-drt.pdf

マニュアル
PDFw468-e1-01_plc-based_process.pdf
...SP 0000 to 2710Hex is s et for 0.00 to 100.00% in the HMI data area. Data is read in percentage unit0.00 ( to 100.00% corres ponds to0000 to2710Hex) and indicated after converted into the engineering unit. ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w468-e1-01_plc-based_process.pdf

マニュアル
PDF[W476-E1-02] GRT1-CRT CompoNet Communications Unit...
.... DIP switch: There is one DIP switch with four pins. You use them to set the operating mode. There is one CompoNet communications connector. Clamp terminals for Unit power supply (24 VDC) Clamp terminals for I/O power supply (24 VDC) 2.5 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w476-e1-02_grt1-crt.pdf

マニュアル
PDF[W484-E1-01] CRT1-VAD02SD/VDA02SD/MLD CompoNet Ana...
...N O P Q R S T Indication on the Numerical indicator k l m n o p r s t Numbers and alphabets in meaning U V W X Y Z Indication on the Numerical indicator u U w x y - . - . 5 5-2-3 Numerical indicator Numbers and alphabets in meaning The characters in blank are not used. 4. SET indicator It lights when Setting Level or Special Function Setting Level is selected. Color State Meaning Yellow Light Setting Level or Special Function Setting Level is selected. - Unlit Other Level is selected. 5. TEACH indicator It lights when ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w484-e1-01_crt1-vad02_d_vda02_d.pdf