ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 9717 件が検索されました。(4821 - 4840件を表示)
マニュアル
PDF[V063-E1-05] NT631-ST211(B)-EV2, NT631C-ST141(B)-E...
...The applicable power supply specifications are as follows. Item Value Power supply 24 VDC Allowable power supply voltage fluctuation range 20.4 to 26.4 VDC (24 VDC –15% to +10%) Power supply voltage capacity NT631-ST211 (B)-EV2: 30 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v063-e1-05_nt631_631c_setup.pdf

マニュアル
PDF[V064-E1-02] NT31-ST121(B)-EV2, NT31C-ST141(B)-EV2...
... Area f L LR Area f --- LR Area*1 n T TC Area, Timer PVs TU --- C TC Area, Counter PVs CU --- --- --- --- TC Area, Counter Completion Flags W --- --- --- --- WR Area TK --- --- --- --- Task Flags D DM Area f DM Area f DM Area f E EM Area *2, current bank f EM Area, current bank n EM Area, current bank n E0_ to EC_ --- --- --- --- EM Area, EM banks 0 to C n --- Timer Area, Timer PVs --- --- TC Area, Timer PVs --- Counter Area, Counter PVs TC area, timer Completion Flags TC Area, Counter PVs f: OK n : NG n: Host link ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v064-02_nt31_nt31c_nt631_nt631c.pdf

マニュアル
PDF[V069-E1-03] NT21, NT31, NT631 Programmable Termin...
...TC area, Timer Completion Flags No C TC Area, Counter PVs No Counter Area, Counter PVs No TC Area, Counter PVs No CU --- --- --- --- TC Area, Counter Completion Flags No W --- --- --- --- WR Area TK --- --- --- --- Task Flags No D DM Area OK DM Area OK DM Area OK E EM Area *2, current bank OK EM Area, current bank E0_ to EC_ --- --- --- Not for Host Link --- Not for Host Link EM Area, current bank Not for Host Link EM Area, EM banks 0 to C Not for Host Link *1: LR 00000 to LR 00199 are converted to CIO 01000 to CIO ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v069-e1-03_nt21_nt31_nt631.pdf

マニュアル
PDF[V072-E1-02] NS7-SV00[]/SV01[], NS10-TV00[]/TV01[]...
... the power supply that can be connected. Determine power supply specifications that meet the power supply capacity requirements. Item Power supply voltage Allowable voltage range Power supply capacity Value 24 VDC 20.4 to 27.6 VDC (24 VDC ±15%) 20 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v072-02_ns12-ts_ns10-tv_ns7-sv.pdf

マニュアル
PDF[V082-E1-10] NS Series Ladder Monitor Operation Ma...
... fluctuation that provides a stable output even if the power supply input is interrupted for 10 ms. The DC power supply must also have reinforced or double insulation. Rated power supply voltage: 24 VDC (Allowable range: 20.4 to 27.6 VDC) Capacity: NS15: 45 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v082-e1-10_ns_ext_operation_manu.pdf

マニュアル
PDF[V085-E1-07] NS5, NS8, NS10, NS12, NS15 Programmab...
...insulation for the power supplies. 5. Do not connect an AC power supply to the power terminals. 6. Use a DC power supply with minimal fluctuation voltage. Rated power supply voltage: 24 VDC (Allowable range: 20.4 to 27.6 VDC) Capacity: 25 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v085-e1-07_ns15_12_10_8_5.pdf

マニュアル
PDF[V086-E1-07] NS-CA002 RGB and Video Input Unit Ope...
.... of video input connectors Input methods Max. simultaneous displays Video display size On-screen positioning Positionable screens Functional object overlap Reference 3-2 2 NTSC or PAL 1 Any size up to 640 x 480 dots (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v086-e1-07_ns-ca002.pdf

マニュアル
PDF[V090-E1-11] NSH5-SQR10B-V2/SQG10B-V2 Hand-held Pr...
..., and station detection. The power supplies must be capable of maintaining stable outputs for momentary power interruptions in the inputs to the power supplies of up to 10 ms. • Rated power supply voltage: 24 VDC (Allowable range: 20.4 to 27.6 VDC) • Capacity: 10 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v090-e1-11_nsh5-sq_10b-v2.pdf

マニュアル
PDF[V091-E1-01] NT-series Programmable Terminal User'...
... not perform a dielectric voltage test on the PT. 7. Use a DC power supply that is isolated between DC output and AC input, and has minimal fluctuation voltage. Rated power supply voltage: 24 VDC (Allowable range: 20.4 to 27.6 VDC) Capacity: 10 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v091-e1-01_nt20.pdf

マニュアル
PDF[V092-E1-13] NS(J)5, NS(J)8, NS(J)10, NS(J)12, NS1...
...contact No No YES YES 1) 2) 3) 9) CC Counter coil No No YES YES 1) 2) 3) D Data register YES YES YES YES 1) 2) 3) 6) W Link register YES YES YES YES 1) 2) 3) 6) R File register Extension file register YES YES YES YES 1) 2) 3) 6) YES YES YES YES 1) 2) 3) 6) 10) T Timer YES YES No No 1) 2) 3) 8) C Counter YES YES No No 1) 2) 3) 8) xxR Restrictions and Notes 1) If "writing operation during run" is disabled, any writing operations are ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v092-e1-13_ns_nsj_nsh.pdf

マニュアル
PDF[V099-E1-12] NS-CXDC1-V3 CX-Designer Ver.3.[] User...
... all objects on the screen. Selects all objects of the same type as the currently selected object. Makes multiple copies of the selected objects. Displays a list of functional objects on screen to enable changing property settings. Ctrl+A Ctrl+D Ctrl+...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v099-e1-12_ns-cxdc1-v3.pdf

マニュアル
PDF[V202-E1-01] C200PC-ISA03-E/ISA[]3-DRM-E/ISA[]3-SR...
...: 350 g max. C200PC-ISAj3-DRM-E, C200PC-ISAj3-SRM-E: 350 g max. Vibration resistance Expansion Option Board: 250 g max. Backup Power Supply Board: 250 g max. Dimensions SYSMAC Board: 106.7 x 163.0 x 16.3 mm (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v202-01_c200pc-isa_3_exp01_pd024.pdf

マニュアル
PDF[V203-E1-03] ITNC-EIS01/EIS01-DRM/EIS01-CST/EIX01/...
...+24 V DC 2 0V 3 Functional ground terminal DC Power Supply Provide a 24-V DC power supply that is within the allowable voltage range (20.4 to 27.6 V DC). Power Supply Capacity The power consumption is 15 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v203-e1-03_itnc-eis_eix.pdf

マニュアル
PDF[V228-E1-02] ITNC-EPX01(-DRM) Open Network Control...
... ISA bus standards. SYSMAC Board Controller Link Support Board SYSMAC LINK Support Board Conforms to PCI bus standards. Controller Link Support Board SYSMAC LINK Support Board CS1 Bus Interface Board Dimensions Weight 234.4 x 140 x 62.4 mm (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v228-e1-02_itnc-epx-drm.pdf

マニュアル
PDFv229-e1-03_3.pdf
... mA max. (Supplied from Power Supply Unit.) CS1W-SPU02: 5 VDC, 700 mA max. (SYSMAC SPU Unit only) Other: Memory Card (HMC-EF@@@): 120 mA max. (Supplied from Power Supply Unit.) CS1W-SPU01/SPU02: 35 × 130 × 101 mm (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v229-e1-03_3.pdf

マニュアル
PDFv236-e1-04_cs1w-spu0_-v2_cj1w-spu01-v2.pdf
... Supply Unit.) CS1W-SPU02-V2: 5 VDC, 700 mA max. (SYSMAC SPU Unit only) Other: Memory Card (HMC-EF@@@): 120 mA max. (Supplied from Power Supply Unit.) CS1W-SPU01/SPU02-V2: CJ1W-SPU01-V2: 35 × 130 × 101 mm (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v236-e1-04_cs1w-spu0_-v2_cj1w-spu01-v2.pdf

マニュアル
PDFv237-e1-04_ws02-sptc1-v2.pdf
...Index sampling data, 258 short-circuits precautions, xxi shutdown settings power failure input, 212 signals precautions, xxi software initial settings, 16 V version changing from SYSMAC SPU Unit Ver. 1.0/1.2/1.3, 293 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v237-e1-04_ws02-sptc1-v2.pdf

マニュアル
PDF[1122981-0D] V520-R221FH/R221SH バーコードリーダ 取扱説明書
...A ITF I UPC-E C NW-7 N JAN/EAN-13 A CODE39 M JAN/EAN-13 B CODE93 L STF (2 of 5 5bar) H CODE128 K EAN128 W 信号名 内 容 3 パリティ EVEN、ODD、 NONE(無し) EVEN ストップビット 1、2 2 データ長 7、8 7 ヘッダ STX、NONE、 ユーザ選択1Byte STX フッタ ETX, CR, ユーザ選択 1Byte/2Byte ETX RS/CS制御 有効、無効 有効 READ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v520-r221fh_sh_inst-1122981-0d.pdf

マニュアル
PDFv600-ham81_inst-1123482-2e.pdf
...NORMAL 13 14 ERR ID0 15 ID1 16 ID2 17 ID3 18 ID4 19 ID5 20 ID6 21 ID7 22 23 24 25 26 R/W − − − FG 説 明 電源入力電源入力インヒビット入力 (AUTO) トリガ入力 (SYNC) 緑リードデータ出力ビット0 一致出力 (VERIFY) 黄リードデータの出力ビット1 白リードデータの出力ビット2 黒リ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v600-ham81_inst-1123482-2e.pdf

マニュアル
PDFv600-ham91_inst-1124676-6e.pdf
...灰/黒 ライトデータ入力ビット7 ID7 ベリファイデータ入力ビット7 (VERIFY) 22 灰/白 リード/ライト切換入力 R/W 23 空き − 24 空き − 25 空き − 26 シールド FG WRITE MODE RUN DATA CONTINUOUS VERIFY BYTE BIT CLEAR BIT SET NORMAL ERROR DATA ERR 7 6 5 4 3 2 1 0 READ OK WRITE NG デ ー タ キ ャ リ ア と の 交 信 モ ー...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v600-ham91_inst-1124676-6e.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。