ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 9717 件が検索されました。(4961 - 4980件を表示)
マニュアル
PDF[Z207-E1-05] ZFV Series Smart Sensor (with Ultra-h...
...Threshold Values AREA BRIGHT CHARA CHARA COUNT MATCH POSITION SEARCH WIDTH THROUGH Timing charts Continuous measurement Synchronous measurement TRIG V VERSION Version 65 65 Wide View 98 W ZFV User’s Manual 109 Section 4 Revision History Revision History A manual revision code appears as a suffix to the catalog number at the bottom of the front and back covers of this manual. Cat. No. Z207-E1-05 Revision code Revision code Section 4 APPENDIX 110 Date Revised contents 01 August 2004 Original production 02 March 2005 Functions added as per software version upgrade (Ver2.00) Information on extension cord ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z207-e1-05_zfv.pdf

マニュアル
PDF[Z211-E1-05] ZEN-V2 Series Programmable Relay Oper...
...Ladder programming is possible directly from CPU Unit. When using LED-type CPU Units (without LCD display) with Memory Cassettes (optional), ladder programs can be easily copied. Smaller Control Panels The ZEN is very small at 90 x 70 x 56 mm (H x ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z211-e1-05_zen-v2.pdf

マニュアル
PDF[Z212-E1-01] ZEN Programmable Relay Communications...
...-485 Signal RS-232C/RS-485 Converter ZEN-10C4DR-D-V2 Signal Terminal FG + − SG B (+) A (−) Shield Comm. RS-485 (+) terminals RS-485 (−) Terminator: ZEN 120 Ω (1/2 W) End node RS-485 Signal Terminal B (+) A (−) End node RS-485 (+) comm. RS-485 (−) terminals Use a terminator of 120 Ω (1/2 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z212-e1-01_zen.pdf

マニュアル
PDF[Z213-E1-01B] V700-L11/HMD13[]/HMD11-1/D23P41-1 RF...
...Precautions for Correct Use 3 Limitations about Model V700-HMD13 4 CONTENTS 5 Section 1 System Features and Configuration 7 1.1 System features 8 1.2 System configuration 9 Section 2 Unit Specifications 2.1 IDR/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z213-e1-01b_v700-l11_hmd1___d23p41-1.pdf

マニュアル
PDF[Z214-E1-01B] V700-L11/L21/HMD13[]/HMD11-1/D23P41 ...
... mounting method 17 2.2 Link unit: Model V700-L11 18 2.2.1 Names and functions of various components/specifications 18 2.2.2 Interface specifications 21 2.2.3 Dimensional drawing and mounting method 24 2.3 IDR/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z214-e1-01b_v700-l21_l11_hmd1___d23p41.pdf

マニュアル
PDF[Z217-E1-01] V700-L12 ID Link Unit User's Manual
...V700-L12 User’s Manual 39 Section 4 Appendix General Specifications Item Specifications and External Dimensions Section 4 No. of connectable Antennas Specification 1 Power supply voltage 24 VDC +10%/−15% Power consumption 10 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z217-e1-01_v700-l12.pdf

マニュアル
PDFz219-e1-05_v600-chud_ch1d-v2_ch1d-psi.pdf
... is treated as an ASCII (or JIS 8) code or hexadecimal code is specified in a command. •ASCII (JIS 8 Code) •One character of ASCII or JIS 8 code data occupies 1 byte (1 address) of the Data Carrier memory. •Example of Specifying ASCII Code ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z219-e1-05_v600-chud_ch1d-v2_ch1d-psi.pdf

マニュアル
PDF[Z221-E1-01] V680-CA1D/CA2D/H01/D1KP58HT Heat-resi...
... as a general-purpose personal computer or Programmable Controller RS-485 78 78 78 78 456 456 78 456 COMM NORM NORM ERR 456 SW3 ERR SW4 SW3 456 R/W ANTENNA R/W ANTENNA RS-485 RS-485 RS-485 + SYNC SW4 R/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z221-e1-01_v680-ca_d_h01_d1kp58ht.pdf

マニュアル
PDFz223-e1-03_e3x-drt21-s.pdf
... supply voltage DC11 to 25 V Current consumption *1 70 mA max. Operating ambient temperature -20 to +55°C Operating ambient humidity 35% to 85% (with no condensation) Storage ambient temperature -30 to +70°C Size (mm) 30.0 (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z223-e1-03_e3x-drt21-s.pdf

マニュアル
PDF[Z234-E1-01] ZEN-10C3AR-A-V2/10C3DR-D-V2 Programma...
.... Easy Operation with an Inexpensive Controller Ladder programming is possible directly from the CPU Unit. With Memory Cassettes (optional), ladder programs can be easily copied. 3 Smaller Control Panels The ZEN is very small at 90 x 70 x 56 mm (H x ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z234-e1-01_zen-10c3_r-_-v2.pdf

マニュアル
PDF[Z235-E1-02] V750-BA50C04-US, V740-HS01CA/HS01LA R...
... Reader/Writer (V750-BA50C04-US) Item SECTION 2 Power supply voltage Specification Reader 12 VDC, via attached AC Adapter.(Less than 28W) AC Adapter 100 to 240 VAC 50/60Hz (0.5 A at 120 V) Power consumption 28 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z235-e1-02_v750-ba50c04-us.pdf

マニュアル
PDF[Z240-E1-05] ZFV-C Smart Sensors (with Ultra-High-...
... of protection IP65 (IEC60529) Standard cable 2 m Robot cable 2 m Standard cable 2 m Robot cable 2 m Standard cable 2 m Robot cable 2 m ZFV-SC_ _ _/SC_ _R: IP65 ZFV-SC_ _ _W: IP67 Material Case: ABS, bracket: PBT Weight Approx. 200 g (including mounting fixture and cord) (When packaged: Approx. 300 g) Approx. 270 g (including mounting fixture and cord) (When packaged: Approx. 350 g) Approx. 300 g (including mounting fixture and cord) (When packaged: Approx. 380 g) Approx. 600 g (including mounting fixture and cord) (When packaged: Approx. 780 g) Accessories Mounting fixture ZFV-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z240-e1-05_zfv-c.pdf

マニュアル
PDF[Z242-E1-04] V400-F050/F250/F350 2D Code Reader Us...
... following points must be observed when reading moving workpieces. • Make sure that the still image display mode is constantly selected. Exposure Time To eliminate image blurring and stabilize reading, refer to the following formula to set the lower limit of exposure time. (Moving shift tolerance: ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z242-e1-04_v400-f050_f250_f350.pdf

マニュアル
PDF[Z250-E1-02] ZG Series Smart Sensor (2D Profile Me...
...Voltage/Current switch 147 20 Wiring the I/O cable 111 ZERO Zero reset Zero Reset indicator ZEROCLR command ZERORST command 51 56 19 138 138 U 5 V APPENDICES W Z ZG User’s Manual INDEX 203 MEMO 204 ZG User’s Manual MEMO 5 APPENDICES ZG User’s Manual 205 MEMO 206 ZG User’s Manual Software Upgrade Information The following describes the details of the software upgrade. Ver1.00 → Ver1.50 Changes Reference The noise filtering function was added on. p.82 The received light gain function was added on. p.82 The slope correction function was ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z250-e1-02_zg.pdf

マニュアル
PDF[Z251-E1-04] ZFX-C10 Smart Sensor (Vision Sensor w...
... output. (0 to 9999.999) Min. pitch (PL) Maximum pitch The maximum detected pitch is output. (0 to 9999.999) Max. pitch (PH) Average width The average detected edge width is output. (0 to 9999.999) Average width (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z251-e1-04_zfx-c10.pdf

マニュアル
PDF[Z252-E1-03] ZFX-C10 Smart Sensor (Vision Sensor w...
...Attribute Specifies measurement item or position correction item. 0: Measurement item 1: Position correction item Default is measurement item. Acquiring/Changing Passwords < PASSWORD command > Acquiring the password This command acquires the currently set password. < Command format > P A S S ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z252-e1-03_zfx-c10.pdf

マニュアル
PDF[Z253-E1-02] V500-R521B2/R521C2 Bar Code Reader Us...
...Q0 '"S" is set. 0S "1" is set. Q1 "T" is set. 0T "2" is set. Q2 "U" is set. 0U "3" is set. Q3 "V" is set. 0V "5" is set. Q5 "W" is set. 0W "6" is set. Q6 "Y" is set. 0Y "7" is set. Q7 V500-R521B2/C2 User’s Manual Section 4 Menu Sheet/Command List "Q" is set. 81 V500-R521.book 82 ページ 2008年7月18日 金曜日 午後1時1分 Section 4 Setting Method Menu sheet Menu sheet Command "8" is set. Q8...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z253-e1-02_v500-r521b2_r521c2.pdf

マニュアル
PDF[Z256-E1-03] ZR-RX20 Portable Multi Logger Start U...
...A/D resolution Photo MOS relay scanning system; all channels isolated 10 ch 16-bit Measurement Voltage ranges Temperature Humidity (*1) Measurement Voltage accuracy Thermo(*2) (*3) couple Thermocouples: K, J, E, T, R, S, B, N, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z256-e1-03_zr-rx20.pdf

マニュアル
PDF[Z257-E1-04] ZR-RX20 Portable Multi Logger User's ...
...-voltage input signals) Item 18 Description Input configuration Isolated input, scanning Analog voltage 20, 50, 100, 200, 500 mV/F.S.; 1, 2, 5, 10, 20, 50 V/F.S.; 1-5V Thermocouples K, J, E, T, R, S, B, N, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z257-e1-04_zr-rx20.pdf

マニュアル
PDF[Z259-E1-03] ZR-RX40 Portable Multi Logger Start U...
...Measurement Voltage ranges Temperature 20, 50, 100, 200, 500 mV; 1, 2, 5, 10, 20, 50 V; 1-5 V F.S. Humidity (*1) Measurement Voltage accuracy Thermocouple Type (*2) (*3) Thermocouples: K, J, E, T, R, S, B, N, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z259-e1-03_zr-rx40.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。