全 2268 件が検索されました。(361 - 380件を表示)
- マニュアル
...䊒䉲䊢䊮ᯏ⢻䈮㒢ቯ䋩 ᒻE5CN/ᒻE5CN-H/ᒻE5CN-HT䇭 JPN 䕧᭄ܹ ᳔2⚍ 䆒ᅮ ᰒ⼎ 䆒ᅮؐⲥ㾚ؐ 㔎ⳕؐऩԡ 0㟇3 䏃SPǂ m-sp NA 0 㞾ࡼࡼˈ䕀ᤶℷড᪡ˈSPᓣߛᤶˈ100% ATᠻ㸠প⍜ˈ ᪡㦰ऩ ࡳ㛑 0.0㟇55.0 ࡴ⛁఼⬉⌕1ؐⲥ㾚ǂ ct1 A 40% ATᠻ㸠প⍜ˈ䆒ᅮᬍবਃ⫼⽕⫼ˈ䗮ֵܹݭਃ⫼⽕⫼ˈ䄺䮽䫕প⍜ㄝ 0.0㟇55.0 ࡴ⛁...
- マニュアル
... 199.9 · Thermistor type (E5CS-@GU) Input G Setting 0 1 2 3 4 5 6 7 8 9 Temperature indication POWER ON Present temperature *1 Set temperature SP indicator lit. Absolute value upper limit 8 * For alarms 1 to 7, set the alarm value (X) to the deviation from the set point. For alarm 8, set the alarm value (Y) to the absolute value from 0°C/°F. * The default is “2” (Deviation upper limit). * The only type of alarm supported for alarm 2 is an upper limit alarm. Set the control temperature. · Thermocouple/platinum resistance thermometer (multi-...
- マニュアル
... operation will be performed when the control output is turned ON. Relay output: The NO contacts will close. Voltage output: 12 V will be output. Temperature indicator LED deviation Temperature indicators indicator Output operation indicator E5CS Mode indicators ...
- マニュアル
... ON Absolute value lower limit standby sequence ON 12 LBA (only for alarm 1) 13 PV Change Rate Alarm ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF SP X SP L H SP L H SP X SP X SP X 0 X 0 X 0 X 0 Vary with "L", "H" values ON OFF ON OFF X ...
- マニュアル
...in-l Scaling (only when setting 0 analog input) M Point dp Decimal (only when setting 0 analog input) M °C = c d-u Temperature °F = f Unit c M sl-h 1300 SP Upper Limit Setting 0 * * * Alarm type sl-l -200 No alarm function stnd Standard or Heating/Cooling Standard control = stnd Heating and cooling control = h-c M st ST (Self-Tuning) ON = on on ST ST OFF = off 1 Deviation upper/lower limit ON OFF 2 Deviation upper limit ON OFF 3 Deviation lower limit ON OFF 4 Deviation upper/lower range ON OFF 5 6...
- マニュアル
...1ѠCT * CT1 26 (-) φؓᣚ⽰ 19 㓵⽰ׁφ 17 * 18 19 20 21 * 22 23 24 25 26 011 6ѠӁԬ䗉ޛȽ1ѠCTȽ1Ѡ䖢ᦘ䗉࠰ૂ1Ѡ䘒ぁSP 䖻ࣟ䗉࠰1Њ4 䖻ࣟ䗉࠰1Ƚ2 17 RS-485 18 䖻ࣟ䗉࠰ ↚䭤᭯ᱴ⽰ᇯȾ 䈛䫤1〈ԛрਃᯯੇᱴ⽰ᇯȾ 8VHQRQYROWDJHLQSXWVIRUWKHHYHQW LQSXWV7KHSRODULW\IRUDQRQFRQWDFWLQSXW LVLQGLFDWHGE\³´ ⧥ູ⒵ᓜ ᆎ۞ᓜ B(+) * 4 5 ᖉ䙐ݷޛߏؗ䇮ᰬ⛯Ӥθ⾷↘ᰬ➺⚣Ⱦ g⁗ᕅ䭤 ֵ⭞䈛䭤࠽ᦘ㨒ঋȾ ⧥ູᓜ 㔝⭫ಞ䗉࠰ 2Ѡ䗉࠰φ250 ...
- マニュアル
... indicators • SUB1 to 4: Auxiliary outputs 1 to 4 indicators • OUT1 to 2: Control outputs 1 to 2 indicators Lit for other than 0% output for linear current output. • TUNE: Lit during AT (auto-tuning). • FSP: Lit when the Fixed ...
- マニュアル
...下限绝对值上限待机序列ON 绝对值下限待机序列ON 12 LBA(仅对报警1) 13 PV变化率报警 14 15 16 17 SP绝对值上限 SP绝对值下限 MV绝对值上限 MV绝对值下限 SP X SP X SP L H ON OFF 5 7 L H ON OFF 偏差上限 10 in-h 100 M 比例缩放上限(仅限设定模拟...
- マニュアル
... indicators • SUB1 to 4: Auxiliary outputs 1 to 4 indicators • OUT1 to 2: Control outputs 1 to 2 indicators Lit for other than 0% output for linear current output. • TUNE: Lit during AT (auto-tuning). • FSP: Lit when the Fixed ...
- マニュアル
... to the set value of the temperature unit. Process value or set data type • No.2 display Set point, set data read-out value or changed input value • No. 3 display • Shift key (PF key) MV, Soak Time Remain, and Multi-...
- マニュアル
...此键, 为PF设置参数设定的功能将生效。 当为电流输出时,除非输出为0%,否则点亮。 ·第三显示 MV、剩余保温时间和多SP。 ·OUT2:控制输出2指示 ·RSP:远程SP指示 ·向上和向下键 ·前面板调试工具端口 每按一次U键,第二显示上的值将增大或显示下一个值。 每...
- マニュアル
...6WDQGDUGFRQWURO stnd +HDWLQJDQGFRROLQJFRQWURO h-c $GDSWLYH&RQWURO 'LVDEOHG off )L[HG fix 1RWLILFDWLRQ info $XWRPDWLFXSGDWH auto 0RGHO&UHDWLRQ 39$PSOLWXGH 100.0 0.0 msp0 stop M sqr p-on sp-m $X[LOLDU\RXWSXW al1h 0 M +HDWHU&XUUHQW 9DOXH0RQLWRU 8QLW$ 0.0 7KH1RGLVSOD\ KDVEHHQRPLWWHG 6RDN7LPH 5HPDLQ 0 o c-o M barh run :KHQFRQWUROVWRS 3UHVV O OHVVWKDQ VHFRQG stop $ODUP9DOXH WR 0.0 off 0.0 $7([HFXWHat-1 off 0.0 +HDWHU&XUUHQW 9DOXH0RQLWRU 8QLW$ M $ODUP9DOXH 8SSHU/LPLW WR 0.0 +HDWHU%XUQRXW 'HWHFWLRQ 8QLW$ M lcr1 $ODUP9DOXH /RZHU/LPLW WR 0.0 /HDNDJH&XUUHQW 9DOXH0RQLWRU...
- マニュアル
...OHVVWKDQ VHFRQG stop $ODUP9DOXH WR c-o M 0.0 (YHQW,QSXW $VVLJQPHQWWR $7([HFXWHat-1 off 0.0 +HDWHU&XUUHQW 9DOXH0RQLWRU 8QLW$ M 0.0 0.0 50.0 sp-0 +6$ODUP 8QLW$ 0.0 2SHUDWLRQOHYHOVKRXOGQRUPDOO\EHXVHGGXULQJRSHUDWLRQV 63WR +ROG ODQGMNH\V GRZQIRUDWOHDVWVHFRQG +ROG ODQGMNH\V GRZQIRUDWOHDVWVHFRQGV 0 M oapt %DU'LVSOD\6FDOLQJ 8SSHU/LPLW 0 M icpt %DU'LVSOD\6FDOLQJ /RZHU/LPLW 1 M 0RYHWR$GYDQFHG )XQFWLRQ6HWWLQJ /HYHO wtpt off M fa pfpt off ,QLWLDO6HWWLQJ &RPPXQLFDWLRQ 3URWHFW 5HVWULFWVPRYHPHQWWRWKH ,QLWLDO6HWWLQJ&RPPXQLFDWLRQV 6HWWLQJDQG$GYDQFHG)XQFWLRQ 6HWWLQJ/HYHOV off M pmsk on M prlp 6HWWLQJ&KDQJH3URWHFW 5HVWULFWVFKDQJHVWRVHWWLQJV E\RSHUDWLQJWKHIURQWSDQHONH\V a-...
- マニュアル
...0RGHO&UHDWLRQ 217LPH M m-of 63 ; 0 M 63 ; ptrn off cp ; M ; 20 M ; &RQWURO2XWSXW 6LJQDO 7UDQVIHU2XWSXW 6LJQDO +ROG OGRZQ IRUDWOHDVW VHFRQG sp-m c-cp 20 M &RQWURO3HULRG&RROLQJ 8QLW6HFRQGV 9ROWDJHRXWSXW IRUGULYLQJ665 21 2)) 09DEVROXWHYDOXHXSSHUOLPLW 21 2)) 09DEVROXWHYDOXHORZHUOLPLW 21 2)) ; ; ; ; 21 2)) 21 2)) 21 2)) 21 2)) ; ; ; ; 8SSHUDQGORZHUOLPLWVFDQEHVHWIRUSDUDPHWHUVDQGWRSURYLGHIRUGLIIHUHQWW\SHV RIDODUP7KHVHDUHLQGLFDWHGE\WKHOHWWHU/DQG+ 7KHGHIDXOWDODUPW\SHLV &RQIRUPDQFHWR(1,(&6WDQGDUGV 7KLVLVDFODVV$SURGXFW ,QUHVLGHQWLDODUHDVLWPD\FDXVHUDGLRLQWHUIHUHQFHLQZKLFKFDVHWKHXVHUPD\EH UHTXLUHGWRWDNHDGHTXDWHPHDVXUHVWRUHGXFHLQWHUIHUHQFH 斲͑͑殯͑͑沖͑͑橎͑͑喺͑͑怾決͑匶匶垚͑櫋怺殯͑筞凃櫖昢͑斲殯穦͑徯洇求...
- マニュアル
... lower limit ON OFF 10 Absolute value upper limit standby sequence ON ON OFF 11 12 13 Absolute value lower limit standby sequence ON LBA (only for alarm 1) PV Change Rate Alarm 14 SP absolute value upper limit ON OFF 15 ...
- マニュアル
...Dimensions 79.2 78 2 44 91 112 96 48 Watertight packing Terminal cover Mounting bracket Mounting the output unit (Number of write operations: 1,000,000) Position proportional potentiometer input, Remote ...
- マニュアル
...OFF ON OFF 9 Absolute value lower limit Absolute value upper limit standby sequence ON Absolute value lower limit standby sequence ON ON OFF LBA (only for alarm 1) 13 PV Change Rate Alarm 14 SP absolute value upper limit ON OFF ON OFF 15 ...
- マニュアル
...(流量)/ ウィンドウモード(流量)時のみ表示 sp2.l 出力 2しきい値 Low ※出力 2 設定:ウィンドウモード(流量)時のみ表示 sp.t.h 出力 2 温度しきい値 High ※出力 2 設定:スタンダードモード(温度)/ ウィンドウモード(温度)時のみ表示 ...
- マニュアル
...OUT1 出力 2 温度しきい値 Low ※出力 2 設定:ウィンドウモード(温度)時のみ表示 OMRON アナログ電流出力モード +V sp.t.l 長押し OUT2 茶 1 標準I/O モード (SIO モード) +V 出力 2 温度しきい値 High ※出力 2 設定:スタンダードモード(温度)/ ウィンドウモード(温...
- マニュアル
...用メニューを表示するために使用します。 単体カメラ形FZ-SC/形FZ-S/ 形FZ-SC2M/形FZ-S2M/ 形FZ-SFC/形FZ-SF/ 形FZ-SPC/形FZ-SP/ 形FZ-SHC/形FZ-SH/ 形FH-SC/形FH-SM/ 形FH-SC02/形FH-SM02/ 形FH-SC04/形FH-SM04/ 形FZ-SC5M2/形FZ-S5M2/ 形FH-SC12/形FH-SM12 タッチパネルモニタ 画像の確認や条件...