全 3026 件が検索されました。(2081 - 2100件を表示)
- マニュアル
...CAUTION E2FM-X1R5□ B C D Toothed washer When mounting the proximity sensor in a metal panel, maintain the clearances given in table3. When installing it with the nut, the value is different depending on the kind of the nut used, ...
- マニュアル
...) ・T形溝以外のシリンダに取り付ける場合は、 別売の取付金具をご使用ください。 ・Please use an attached cable clip. ・The protrusion wears away when installing.So this product is fixed temporarily. ・Please fix this product with an attached screw. (Tightening Torque:max.0.4N・m) ・When this product is installed in other than T-groove cylinder, please use the mounting brackets(order separately). 0V 当社適合コネクタコード: XS2Fシリ...
- マニュアル
...) ・T形溝以外のシリンダに取り付ける場合は、 別売の取付金具をご使用ください。 ・Please use an attached cable clip. ・The protrusion wears away when installing.So this product is fixed temporarily. ・Please fix this product with an attached screw. (Tightening Torque:max.0.4N・m) ・When this product is installed in other than T-groove cylinder, please use the mounting brackets(order separately). 0V Precautions For Safe Use 以下に示すような項目...
- マニュアル
... it after confirming the installation distance by following (a) and (b) with an actual sensing object when you install the sensor. (a)The detection distance receives the influence by the material of the sensing object, thickness, shape, and the size. ...
- マニュアル
... communications are not possible with an E3X-DA-N Amplifier Unit. 12) Depending on the application environment, time may be required for the incident light level to stabi-lize after the power supply is turned ON. 13) Output pulses may occur when the power is interrupted and ...
- マニュアル
...which cannot be used in part. Other Mobile Consoles, such as the E3X-MC11, cannot be used. 9) Optical communications are not possible at the time of connection use with an E3X-DA-N Amplifier Unit. 10) Output pulses may occur when the power is interrupted and ...
- マニュアル
... communications are not possible with an E3X-DA-N Amplifier Unit. 10) Depending on the application environment, time may be required for the incident light level to stabi-lize after the power supply is turned ON. 11) Output pulses may occur when the power is interrupted and ...
- マニュアル
... OR IMPLIED. Receiver Do not install the E3FS in a location where it can be affected by wall reflections to avoid detection failure, which may result in serious injury. When using multiple sets of E3FS, arrange them to prevent mutual interference. Failure to do ...
- マニュアル
...説明書 (日/英語) ● Operation indicator (orange) : Lighis up when the output is given. DISTANCE is given indicator (green) : Indicates a relative distance with respect to the threshold. Setup direction (7) Be sure to place the photoelectric switch ...
- マニュアル
....3mm2 min. and 100m max. in length. ・Be sure to connect the photoelectric switch in series with a load to the power source. Otherwise direct connection of the switch may cause damage the switch. ・Do not short-circuit the load. Doing ...
- マニュアル
... photoelectric switch because they may damage its water-resistire characteristic. ・Be sure to connect the photoelectric switch in series with a load to the power source, otherwise direct connection of the switch may cause damage to the switch. ・Do not short-circuit the load. Doing ...
- マニュアル
... damage the lens of the emitter unit. Brown(+V) Brown(+V) -DS50E4 -DS50B4 1.5 to 4mA ● INDICATION ・The green and red indicators turn on and off as shown in below chart. ・Set the sensitivity adjuster at an appropriate position ...
- マニュアル
... use in environments with high levels of strong acid, alcohole and organic solvent ,as it will damage the lens of the emitter unit. ●Indication ・The green and red indicators turn on and off as shown in below chart. ・Set the sensitivity adjuster at an appropriate position ...
- マニュアル
... CORRECT USE (1) Do not use the product in the following places. Place exposed to direct sunlight. Place where humidity is high and condensation may occur. Place where corrosive gas exists. Place where vibration or shock is directly transmitted to the product. (2) Install ...
- マニュアル
...SELECT Sample color registration Press the Teach Button to register the color to be detected. TEACH Tolerance adjustment (*1 ) Press the Select Button and set the tolerance level while monitoring the tolerance level indicator. Detection Set the mode selector to RUN ...
- マニュアル
... Teach Button to register the color to be detected. Tolerance adjustment ADJUST mode (*1 ) Press the Select Button and set Teach Adj Run the tolerance level while monitoring the tolerance level indicator. Detection RUN mode Set the mode selector to RUN ...
- マニュアル
... the Select Button while monitoring the tolerance level indicator, and set the tolerance level to the best level. Tolerance adjustment (*1 ) Press the Select Button and set the tolerance level while monitoring the tolerance level indicator. Detection Set the mode selector to RUN ...
- マニュアル
..., benzine, acetone, or kerosene for cleaning the Amplifier Unit. 15)Do not pull or apply excessive pressure or force (exceeding 9.8 N・m) on the Fiber Unit when it is mounted to the Amplifier Unit. 16)Output pulses may occur when the power is interrupted and ...
- マニュアル
..., benzine, acetone, or kerosene for cleaning the Amplifier Unit. 15)Do not pull or apply excessive pressure or force (exceeding 9.8 N・m) on the Fiber Unit when it is mounted to the Amplifier Unit. 16)Output pulses may occur when the power is interrupted and ...
- マニュアル
... connected amplifiers at the power supply turning on time is 30ms or more. 7)Depending on the application environment, time may be required for the light level to stabilize after the power supply is turned ON. 8)Output pulses may occur when the power is interrupted, ...