ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 2558 件が検索されました。(1501 - 1520件を表示)
マニュアル
PDF[Z442-E-01] F430-F Series Smart camera NJ Series S...
... to the following wiring. Serial communication unit RS-232C-I/O 2 Pronge Cable (CJ1W-SCU22) side (V430-W2-3M) end Signal Signal Pin No. Pin No. Name Name FG 1 1 NC SD 2 2 Host_RxD RD 3 3 Host_TxD RS-232C RS-232C RS 4 4 NC Interface Interface CS 5 5 0V 5V 6 6 NC DR 7 7 NC ER 8 8 NC SG 9 9 NC FG Shell Shell FG D-SUB 9 Pin D-SUB 9 Pin Cable Connector Type: Male Cable Connector Type: Male NJ501-1500 CJ1W-SCU22 F430-F00M12M...

https://www.fa.omron.co.jp/data_pdf/mnu/z442-e-01_f430-f.pdf

マニュアル
PDF[Z444-E-05] MicroHAWK F440-F/F430-F/F420-F Series ...
... following is the wiring diagram of the power cable to connect to the smart camera (All V430-W8). Smart Camera Brown 24V Blue 0V Red COM_IN 2 Red striped COM_OUT TRIG Black RD Purple SD Gray OUTPUT1 Gray striped OUTPUT2 Pink OUTPUT3 Green DEFAULT Yellow NEW MASTER None (Shield) Colors for each wire Wire color Pin No. Signal Name Function Brown 2 24V Power supply Blue 7 0V GND Red 8 COM_IN Common Input Signals (Input Common) Red striped 12 COM_OUT Common Output Signals (Output Common) White 1 TRIG Measurement Trigger Input (When the trigger...

https://www.fa.omron.co.jp/data_pdf/mnu/z444-e-05_f4_0-f.pdf

マニュアル
PDF[Z445-E1-03] FH-505[]/SMDA-GS050B Vision System Pr...
... other countries. • Intel, Core and Pentium are trademarks of Intel Corporation in the U.S. and/or other countries. • EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. • ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA. • The ...

https://www.fa.omron.co.jp/data_pdf/mnu/z445-e1-03_fh-505__smda-gs050b.pdf

マニュアル
PDF[Z446-E1-06] FH-505[]/SMDA-GS050B Vision System 3D...
... other countries. • Intel, Core and Pentium are trademarks of Intel Corporation in the U.S. and/or other countries. • EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. • ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA. • The ...

https://www.fa.omron.co.jp/data_pdf/mnu/z446-e1-06_fh.pdf

マニュアル
PDFV440-F C-Mount Code Reader User Manual
.... When constructing an intranet, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. Take adequate measures, such as restricting physical access to network devices, by such means as locking the installation area. When using a device equipped with the ...

https://www.fa.omron.co.jp/data_pdf/mnu/z452-e-05 (84-9000440-02)_v440-f.pdf

マニュアル
PDF[Z453-E-03] V440-F C-Mount Code Reader Communicati...
... to connect to the V440-F (All V430-W8). Code Reader Brown 24V Blue 0V Red COM_IN Red / Black COM_OUT Wire color 2-4 Pin No. White TRIG Black RD Purple SD Gray OUTPUT1 Gray / Red OUTPUT2 Pink OUTPUT3 Green DEFAULT Yellow NEW MASTER None (Shield) Signal Name Function Brown 2 24V Power supply Blue 7 0V GND Red 8 COM_IN Common Input Signals (Input Common) Red / Black 12 COM_OUT Common Output Signals (Output Common) White 1 TRIG Read Trigger Input (Trigger) Black 9 RD Receive Data (RD) Purple 10 ...

https://www.fa.omron.co.jp/data_pdf/mnu/z453-e-03_v440-f.pdf

マニュアル
PDFV460-H Industrial Handheld DPM Reader
.... When constructing an intranet, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. Take adequate measures, such as restricting physical access to network devices, by such means as locking the installation area. When using a device equipped with the ...

https://www.fa.omron.co.jp/data_pdf/mnu/z461-e-04 (84-9000460-02)_v460-h.pdf

マニュアル
PDF[Z470-E1-01] ZS-HL-N Series Smart Sensors 2D CMOS ...
...10 1 2 6 NC Pin No. 1 Pin No. 1 Signal name Section7 USB/RS-232C COMMUNICATION Controller side 3 7 4 8 5 9 Signal name NC SD(TXD) 2 2 SD(TXD) RD(RXD) 3 3 RD(RXD) RS(RTS) 4 4 RS(RTS) CS(CTS) 5 5 CS(CTS) NC 6 6 NC NC 7 7 NC NC 8 8 NC SG(GND) NC FG 9 9 SG(GND) 10 Shell Shell FG Note 1: Plug type connector ZS-HL-N User’s Manual 7-5 Section7 Connecting Using a RS-232C Cable  RS-232C ...

https://www.fa.omron.co.jp/data_pdf/mnu/z470-e1-01_zs-hl-n.pdf

マニュアル
PDFAutofocus Multicode Reader VHV5-F Series
... of unauthorized network equipment. Take adequate measures, such as restricting physical access to network devices, by means such as locking the installation area. Autofocus Multicode Reader VHV5-F Series User Manual (Z476-E) 19 Safety Precautions When using a device equipped with the ...

https://www.fa.omron.co.jp/data_pdf/mnu/z476-e-03_vhv5-f.pdf

マニュアル
PDFAutofocus Multicode Reader VHV5-F Series
...300 I/O connector (M12 12-pin plug) Please connect V430-W8£ to the I/O connector (M12 plug) and connect it to power supply etc. RS-232C (D-sub 9 Pin Female Connector) Pin No. Signal Name 1 – 2 SD 3 RD 4 – 5 0V 6 – 7 – 8 – 9 – Pin Layout Diagram 5 3 2 Using the RS-232C Signal on I/O Cable (V430-W8£) RS-232C communication is possible by combining the signal for RS-232C communication (...

https://www.fa.omron.co.jp/data_pdf/mnu/z477-e-01_vhv5-f.pdf

マニュアル
PDFZP Series Laser Displacement Sensor
... terminals, using terminals with secure functions, and locking the installation area. When building an intranet, communications problems may occur due to cable disconnection or unauthorized network equipment. Take adequate measures to restrict physical access to network equipment, for example, by locking the installation area. Equipment with ...

https://www.fa.omron.co.jp/data_pdf/mnu/z495-e1-03_zp-l.pdf

マニュアル
PDFZP-series EtherNet/IP™ Communication Unit
... terminals, using terminals with secure functions, and locking the installation area. When building an intranet, communications problems may occur due to cable disconnection or unauthorized network equipment. Take adequate measures to restrict physical access to network equipment, for example, by locking the installation area. Equipment with ...

https://www.fa.omron.co.jp/data_pdf/mnu/z496-e1-02_zp-eip.pdf

マニュアル
PDFCIDRW SYSTEM V640 SERIES AMPLIFIER UNITS ETHERNET ...
.... When constructing an intranet, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. Take adequate measures, such as restricting physical access to network devices, by means such as locking the installation area. When using a device equipped with the ...

https://www.fa.omron.co.jp/data_pdf/mnu/z497-e1-02_v640-ham11(-l)-etn-v.pdf

マニュアル
PDFZP-series RS-232C Communication Unit
... terminals, using terminals with secure functions, and locking the installation area. When building an intranet, communications problems may occur due to cable disconnection or unauthorized network equipment. Take adequate measures to restrict physical access to network equipment, for example, by locking the installation area. Equipment with ...

https://www.fa.omron.co.jp/data_pdf/mnu/z499-e1-01_zp-rsa.pdf

マニュアル
PDFVision Sensor FHV7-AI Series AI Detection Camera
... Microsoft Corporation in the United States and other countries. • Intel, Core and Pentium are trademarks of Intel Corporation in the U.S. and/or other countries. • ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA. • The microSD and microSDHC logos are trademarks of ...

https://www.fa.omron.co.jp/data_pdf/mnu/z507-e1-02_fhv7x-c016-s__-w-01.pdf

マニュアル
PDFVision Sensor FH-UMLIC-08 FH Application Software
... other countries. • Intel, Core and Pentium are trademarks of Intel Corporation in the U.S. and/or other countries. • EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. • ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA. • The ...

https://www.fa.omron.co.jp/data_pdf/mnu/z511-e1-01_fh-umlic-08.pdf

マニュアル
PDF[Z924-E1-02] G9SP Series Safety Controller Host Co...
... connecting with a Mitsubishi Electric Standard PLC Q series (QJ71C24N-R2). G9SP-series Mitsubishi Electric Q series serial communication module RS-232C Serial Communications Board Connector Pin No. Pin No. Signal FG 1 1 CD ...

https://www.fa.omron.co.jp/data_pdf/mnu/z924-e1-02_g9sp.pdf

マニュアル
PDF[7994259-0D] ZJ-SF11 形ZJ用インターフェイスユニット 取扱説明書 (日/英語)
... (p-p)10% 以下アンプユニットから供給 22 形 ■取付方法 電源電圧 36.8 ■定格 ピン番号 名 称 N.C. RD SD N.C. センサ通信表示灯 (通信エラ−) SG. N.C. N.C. * 7 9 9 4 2 5 9 - 0 D * © OMRON Corporation 2005 All Rights Reserved. N.C. DINレ−ル N.C. INTERFACE UNIT 安全上の要点次に示す項目は安全を...

https://www.fa.omron.co.jp/data_pdf/mnu/zj-sf11_inst-7994259-0d.pdf

マニュアル
PDF[7971166-1B] ZJ-XBU1 形ZJ-S□□用取付金具 取扱説明書
...・ZJ-S と ZX-UD 取付け時寸法 ・ZJ-S と ZX-LD 取付け時寸法 (110) 4.2 6-φ 55 35.7 形ZX-UD30L 形ZX-LD100 (40.16) 形ZJ-SD 9 16 1.4 23.5 47 62 0120-919-066 形ZJ-SD 16.5 検出部 クイック オムロン 43 携帯電話・PHS・IP電話などではご利用いただけませんので、下記の電話番...

https://www.fa.omron.co.jp/data_pdf/mnu/zj-xbu1_inst-7971166-1b.pdf

マニュアル
PDFFor further information, refer to the Instruction ...
...For further information, refer to the Instruction Sheet in the For further information, refer to the Instruction Sheet in the package and a user's manual. G Recommended SD card: HMC-SD292(2GB)/HMC-SD492(4GB) Recommended ...

https://www.fa.omron.co.jp/data_pdf/mnu/zn-ctx21-_(startupguide)_inst-5337005-0g.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。