全 2711 件が検索されました。(1461 - 1480件を表示)
- マニュアル
...[Z174-E1-02A] CS1W-V600C11/V600C12, CJ1W-V600C11/V600C12 ID Sensor Units Operation Manual Cat. No. Z174-E1-02A SYSMAC CS/CJ Series CS1W-V600C11 CS1W-V600C12 CJ1W-V600C11 CJ1W-V600C12 ID Sensor Units SYSMAC ...
- マニュアル
...3 SD 3 SD 4 N.C. 4 ER 5 SG 5 SG 6 N.C. 6 DR 7 N.C. 7 RS 8 N.C. 8 CS 9 N.C. 9 CI Connector hood FG * Pin Nos. may vary with the type and model of the external device to be connected.For details, refer to the instruction manual of your programmable controller or personal computer. ZX-L-N User’s Manual Section 7 APPENDIX Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p) 10% max. Supplied from Amplifier Unit Current consumption Power supply voltage: 12 V, Current ...
- マニュアル
... as the current transformer. Section 2-2 How To Use the Terminals Connection Examples Example Connection with the PLC Preparations Heater Alarm output 20 mm min. (See note.) RS-232C/485 Power Controller power supply ...
- マニュアル
...Signal Name NC Pin No. 1 Pin No. 1 Signal Name NC SD(TXD) 2 2 RD(RXD) RD(RXD) 3 3 SD(TXD) RS(RTS) 4 4 NC CS(CTS) 5 5 SG(GND) NC 6 6 NC NC 7 7 RS(RTS) NC 8 8 CS(CTS) SG(GND) NC 9 9 NC 6 7 8 9 10 ZS-L User’s Manual 4-11 Section 4 RS-232C Input/Output Setting the Communication Specifications Set the RS-232C communications specifications. Match the communication specifications of the ZS-L Series to those of the external device. FUN mode-[...
- マニュアル
...1 Section 5 APPENDIX 6 7 NC Pin No. 1 Pin No. 1 Signal Name NC SD(TXD) 2 2 RD(RXD) 3 3 SD(TXD) 4 4 NC CS(CTS) 5 5 SG(GND) NC 6 6 NC NC 7 7 RS(RTS) NC 8 8 CS(CTS) 9 9 NC Signal Name RD(RXD) RS(RTS) SG(GND) NC 10 Item 5-10 8 9 ZS-XRS2 Applicable controller ZS Series Ambient temperature Operating: 0 to 50°C, Storage: -15 to +60°C (with no icing or condensation) Ambient humidity Operating and storage: 35% to 85% RH (with ...
- マニュアル
...Signal name 4-4 ZS-DSU User’s Manual 8 9 Signal name NC SD(TXD) 2 2 RD(RXD) RD(RXD) 3 3 SD(TXD) RS(RTS) 4 4 NC CS(CTS) 5 5 SG(GND) NC 6 6 NC NC 7 7 RS(RTS) NC 8 8 CS(CTS) SG(GND) NC 9 9 NC 10 Section 4 RS-232C Input/Output Setting the Communication Specifications Set the RS-232C communications specifications. Match the communication specifications of the ZS-DSU to those of the external device. FUN Mode-[SYSTEM]-[COM] Setting RS232C Range LENGTH 8BIT, 7BIT (default value: ...
- マニュアル
...2 RD SD 3 3 SD NC 4 4 NC SG 5 5 SG NC 6 6 NC RS 7 7 RS NC 8 8 CS NC 9 9 NC Ground shielded wires either at the CIDRW Controller side or at the PC/AT side. CIDRW System User’s Manual SECTION 2 Connections and Wiring CIDRW Controller V700-L22 D-SUB, 9-pin Socket type #4-40 29 SECTION 2 Installation and Connections/Wiring Amplifier Unit ■ Connector for connecting a CIDRW Head 1. Align the pin on the connector with the Connections and Wiring SECTION 2 channel in the cable ...
- マニュアル
...Controller side 3 7 4 8 5 9 Signal name NC SD(TXD) 2 2 SD(TXD) RD(RXD) 3 3 RD(RXD) RS(RTS) 4 4 RS(RTS) CS(CTS) 5 5 CS(CTS) NC 6 6 NC NC 7 7 NC NC 8 8 NC SG(GND) NC FG 9 9 SG(GND) 10 Shell Shell FG Note 1: Plug type connector ZS-HL User’s Manual 7-5 Section7 Connecting Using a RS-232C Cable RS-232C Cable for Connecting to a Personal Computer • ZS-XRS2 (cable length: 2 m) Controller side Personal computer side (PC/...
- マニュアル
...3 SD 3 SD 4 N.C. 4 ER 5 SG 5 SG 6 N.C. 6 DR 7 N.C. 7 RS 8 N.C. 8 CS 9 N.C. 9 Connector hood CI FG * Pin No. may vary with the type and model of the external device to be connected. For details, refer to the instruction manual of your programmable controller or personal computer. 122 ZJ-SD User’s Manual Section 7 Specifications and Dimensions Item ZJ-SF11 Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p) 10% max. Supplied from Amplifier Unit Current consumption At ...
- マニュアル
...Product Configuration A V680-series RFID System consists of an ID Controller, one or more Amplifiers, one or two Antennas, and Section 1 Product Configuration RF Tags. Select the models suitable for the application. Using Antennas with Separate Amplifiers Programmable Controller (SYSMAC ...
- マニュアル
...) Product versions are displayed on the monitor display when the power supply is turned ON. To use the V680-CA5D01-V2, it must be version 2.3 or newer. To use the V680-CH@D, it must be version 1.1 or newer. To use the ...
- マニュアル
...Product Configuration A V680-series RFID System consists of an ID Controller, one or more Amplifiers, one or two Antennas, and Section 1 Product Configuration RF Tags. Select the models suitable for the application. Using Antennas with Separate Amplifiers Programmable Controller (SYSMAC ...
- マニュアル
...Product Configuration A V680-series RFID System consists of an ID Controller, one or more Amplifiers, one or two Antennas, and Section 1 Product Configuration RF Tags. Select the models suitable for the application. Using Antennas with Separate Amplifiers Programmable Controller (SYSMAC ...
- マニュアル
...3 SD 3 SD 4 N.C. 4 ER 5 SG 5 SG 6 N.C. 6 DR 7 N.C. 7 RS 8 N.C. 8 CS 9 N.C. 9 CI Shell FG COMMUNICATIONS WITH EXTERNAL DEVICES Connector Pin Arrangement and Connection Example with a PC * Pin Nos. may vary with the type and model of the external device to be connected. For details, refer to the instruction manual of your PC or PLC. ZX-GT User’s Manual RS-232C 101 About Communications Commands Command/Response Format Important The command/response format differs according to the RS-...
- マニュアル
...3 SD 3 SD 4 N.C. 4 ER 5 SG 5 SG 6 N.C. 6 DR 7 N.C. 7 RS 8 N.C. 8 CS 9 N.C. 9 Connector hood CI FG * Pin Nos. may vary with the type and model of the external device to be connected. For details, refer to the instruction manual of your programmable controller or personal computer. ZN System Manual Section 4 Specifications and Dimensions Clean Monitoring System Item Power supply voltage ZN-SFW11 ZN-SFW12 Supplied from ZN-PDA Current consumption 45 mA with 24 VDC without Amplifier Unit Available ...
- マニュアル
...a host computer. • Insert a Cramp Filter (E04SR301334 manufactured by SEIWA) in the cable as a countermeasure against noise. RS-232C interface Computer Name Pin Pin CD RD SD ER SG DR RS CS C1 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 K3SC-10 Name Name PWR NC SG PWR SD RD SG RDA(−) SDA(−) NC RDB(+) SDB(+) RS-485 Pin 7 8 9 10 11 12 (See note.) S8AS A(−) B(+) Clamp filter We recommend twisting the RS-485 communications lines. (See note.) RS-485 S8AS A(−) B(+) (See note.) Power ...
- マニュアル
... use the V680/V680S-series RFID System correctly. • Keep this manual in a safe and accessible location so that it is available for reference when required. READ AND UNDERSTAND THIS DOCUMENT Section 1 Features and System Configuration Introduction SECTION 1 Introduction Section 2 ...
- マニュアル
... use the V680/V680S-series RFID System correctly. • Keep this manual in a safe and accessible location so that it is available for reference when required. READ AND UNDERSTAND THIS DOCUMENT Section 1 Features and System Configuration Introduction SECTION 1 Introduction Section 2 ...
- マニュアル
... sure that the version allows setting the Tag memory setting to CA1D Mode. To use the V680-CA5D01-V2/-CA5D02-V2, it must be version 2.3 or newer. To use the V680-CH@D, it must be version 1.1 or newer. To use the ...
- マニュアル
... can be used to read and set Sensor parameters and to execute measurements. 1-2 1-1 Features and System Configuration 1-1-2 Features 1 Communications Interface That Connects Smart Sensors with a Host, Including OMRON PLCs (such as the ...