PDF[2288325-3C] E3NX-MA□□シリーズ スマートファイバアンプ 取扱説明書(日/英/中...
...; bending: 29.4N · Use the fiber unit E32-□□. · Do not apply excessive force such as tension, compression or torsion to the amplifier unit with the fiber unit fixed to the amplifier unit. · Always keep the protective cover in place when using the product. Not doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3nx-ma__series_inst-2288325-3c.pdf

マニュアル
PDF[6918323-3D] E3S-AD14/AD64 光電センサ 取扱説明書 (日/英語)
...) nearly agrees with optical axis. That is, when the mounting face and screw hole are properly directed toward a detection object, fitting the screw in this hole positively allows the machine axis and optical axis to agree with each other, achieving incident condition, ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3s-ad14_ad64_inst-6918323-3d.pdf

マニュアル
PDF[9539398-0B] E3S-DC[][] Series Color Mark Photoele...
... list [Timer indicator] Turns ON when timer setting is activated TH 2016 All Rights Reserved. 1 Installation EP © OMRON Corporation · Note that the water-resistant function is impaired if installing the photoelectric sensor by hitting it with a hammer and ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3s-dc__series_inst-9539398-0b.pdf

マニュアル
PDF[5977293-1E] E3S-R□□ 光電センサ 取扱説明書 (日/英語)
... ADJUSTMENT Attached spacer (for connector type only) A 100mA Max. Sensitivity volume Mode change-over switch Push in until the face is in close contact with the nameplete ・To sense a cylindrical object, install the sensor and reflector ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3s-r___inst-5977293-1e.pdf

マニュアル
PDF[5345304-4E] E3T-□ 光電センサ 取扱説明書 (日/英/韓語)
...* Unstable range * Stable interrupted range *2 *1 透過形 20mA以下 制御出力 ・The green indicator turn ON and OFF as shown in below chart. ・Set the sensor at an appropriate position so that it operates within the stable operating range. * Stable incident range E3T-ST31/ST32 E3T-ST33/ST34 DC12∼24V±10% (リップル(p-p)10%以下) *Terminal 2 is not used. (Reflection type or Receiver) **Terminal 2 and 4 are not used. (Light source) Operating Level × 1.2 Load(Relay) BGS形 投光器:10mA...

https://www.fa.omron.co.jp/data_pdf/mnu/e3t-__inst-5345304-4e.pdf

マニュアル
PDF・高圧線、動力線と光電スイッチの配線が同一配管あるいはダクトで行 ■定格/性能
...留電圧:2V以下(負荷電流10∼50mA)1V以下(負荷電流10mA未満)],漏れ電流10μA以下 ・The green indicator turn ON and OFF as shown in below chart. ・Set the sensor at an appropriate position so that it operates within the stable operating range. * Unstable range * Stable interrupted range *1 DC12∼24V±10% (リップル(p-p)10%以下)Class2 投光器:10mA以下受光器:20mA以下 *Terminal 2 is not used. (Reflection type or Receiver) **Terminal 2 and ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3t-__inst-5822505-8a.pdf

マニュアル
PDF・高圧線、動力線と光電スイッチの配線が同一配管あるいはダクトで行 ■定格/性能
...タ ■INDICATOR Operating Level *1 E3T-ST31F/ST32F E3T-ST33F/ST34F 300mm 20mA以下 動作モード ・The green indicator turn ON and OFF as shown in below chart. ・Set the sensor at an appropriate position so...

https://www.fa.omron.co.jp/data_pdf/mnu/e3t-__inst-5822519-8a.pdf

マニュアル
PDF[5319306-9B] E3X-DA□□TG-S デジタルファイバセンサ 取扱説明書 (日/英/韓...
...* 5 3 1 9 3 0 6 - 9 B * Precaution on Safety 13)Depending on the application environment, time may be required for the incident light level to stabilize after the power supply is turned ON. 14)Output pulses may occur when the power is interrupted, ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3x-da__tg-s_inst-5319306-9b.pdf

マニュアル
PDF[4018719-1C] E3X-HDシリーズ スマートファイバセンサ 取扱説明書 (日/英/中語)
... function among the E3X-DA-N/SD/NA amplifiers. It functions among E3X-DA-S/MDA models. • The E3X-DRT21-S, E3X-CRT and E3X-ECT Communication Units cannot be used. • Always keep the protective cover in place when using the Amplifier Unit. Not doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3x-hdseries_inst-4018719-1c.pdf

マニュアル
PDF[3624527-6A] E3X-MZV Series (External input models...
... prevention function may not work properly, resulting in malfunction of the unit. In such case, increase the threshold. · Do not use the unit when EEPROM (non-volatile memory) exceeds its writing life (100,000 times). When you perform setting change, threshold change, tuning, zero reset and ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3x-mzvseries_inst-3624527-6a.pdf

マニュアル
PDF[6954872-0C1] E3X-NA ファイバ光電センサ 取扱説明書 (日/英/韓語)
... for E3X-NA51 ■Precautions for use DIN rail (2) Mutual interference preventing function E3X-NA series except for E3X-NA□□F has the small windows on the both side of the case. These are for preventing mutual interference, when connecting the sensors. ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3x-na_inst-6954872-0c1.pdf

マニュアル
PDF[2117675-8D] E3X-SD21/SD51/SD7/SD9 ファイバセンサ 取扱説明書 (...
... Amplifier Unit is ready to operate 200 ms after the power supply is turned ON. If the Amplifier Unit and load are connected to power supplies separately, turn ON the power supply to the Amplifier Unit first. 5)Output pulses may occur when the power is interrupted, ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3x-sd21_sd51_sd7_sd9_inst-2117675-8d.pdf

マニュアル
PDF[3624526-8A] E3X-ZV Series (External input models)...
....Additionally there may be significant property damage. Blue External input 0V 12 to 24 VDC External input Brown Black: Control Output PRECAUTIONS FOR SAFE USE The following precautions must be observed to ensure safe operation of the product. Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3x-zvseries_inst-3624526-8a.pdf

マニュアル
PDF[5637776-4F] E3X-ZV Series (Standard models/Enhanc...
... situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death.Additionally there may be significant property damage. PRECAUTIONS FOR SAFE USE The following precautions must be observed to ensure safe operation of the product. Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3x-zvseries_inst-5637776-4f.pdf

マニュアル
PDFLASER レーザ製品を安全に使用していただくために 使用上の注意 ■外形寸法図 Laser saf...
...Ne regardez pas directement dans la lumière sortante. Attention-L’utilisation des commandes ou réglages ou l’exécution des procédures autres que celles spécifiées dans les présentes exigences peuvent étre la cause d’une exposition à un rayonnement dangereux. Do not disassemble this product.Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3z-l___-ul_inst-3665864-3f.pdf

マニュアル
PDFレーザ製品を安全に使用していただくために ■外形寸法図 To safely use laser pr...
...Ne regardez pas directement dans la lumière sortante. Attention-L’utilisation des commandes ou réglages ou l’exécution des procédures autres que celles spécifiées dans les présentes exigences peuvent étre la cause d’une exposition à un rayonnement dangereux. Do not disassemble this product.Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3z-l____inst-7978946-6l.pdf

マニュアル
PDFPrecautions for Safe Use ②There are some cases whe...
... wird. (4) Spannungsversorgung Achten Sie bei Verwendung eines handelsüblichen Schaltnetzteils darauf, dass der Gehäuseerdungsanschluss ordnungsgemäß geerdet ist. (5) Spannungsversorgungs-Rücksetzzeit Der Sensor nimmt seinen Betrieb spätestens 100 ms nach Einschalten der Versorgungs-spannung auf. Werden Last und Sensor von verschiedenen Spannungsquellen gespeist, ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3zm-____inst-7978985-7h.pdf

マニュアル
PDF[3705140-8D] E3ZM-B 光電センサ 取扱説明書 (日/英/伊/独/仏/西語)
... abziehen. (3) Spannungsversorgung Achten Sie bei Verwendung eines handelsüblichen Schaltnetzteils darauf, dass der Gehäuseerdungsanschluss ordnungsgemäß geerdet ist. (4) Spannungsversorgungs-Rücksetzzeit Der Sensor nimmt seinen Betrieb spätestens 100 ms nach Einschalten der Versorgungs-spannung auf. Werden Last und Sensor von verschiedenen Spannungsquellen gespeist, ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3zm-b_inst-3705140-8d.pdf

マニュアル
PDFPrecautions for Safe Use ②There are some cases whe...
... wird. (4) Spannungsversorgung Achten Sie bei Verwendung eines handelsüblichen Schaltnetzteils darauf, dass der Gehäuseerdungsanschluss ordnungsgemäß geerdet ist. (5) Spannungsversorgungs-Rücksetzzeit Der Sensor nimmt seinen Betrieb spätestens 100 ms nach Einschalten der Versorgungs-spannung auf. Werden Last und Sensor von verschiedenen Spannungsquellen gespeist, ...

https://www.fa.omron.co.jp/data_pdf/mnu/e3zm-c____inst-0979013-0h.pdf

マニュアル
PDF[7912175-9L] E3ZS-T81A シングルビームセーフティセンサ 取扱説明書 (日/英語...
...receiver (Operating range L ) Minimum installation distance D 0.2 to 3 m 0.27 m or more  INFLUENCE OF MUTUAL INTERFERENCE When installing two or more E3ZSs to each other, considerations must be made to prevent mutual interference. • Install ...