PDF[Z108-E1-02A] F350-C12E/C41E Visual Inspection Sys...
...XM2A-2501 25 13 14 1 Symbol Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 DR (DSR) Data Settings Ready 7 SG (GND) Signal ground 20 ER (DTR) Data Terminal Ready 25 Section 2-4 Connecting Power Supply Unit I/O Terminals Use only shielded RS-232C cable. Wiring Standard 25-pin Cable Connection (F309-VR) F300-E2 9-pin Cable Connection RS-232C Device RS-232C Device F300-E2 Symbol Pin no. Pin no. Symbol Symbol Pin no....

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z108-02a_f350-c12e_c41e.pdf

マニュアル
PDF[Z124-E1-01B] F150-C10E Visual Inspection System S...
... pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 30 Model No. Plug XM2A-0901 Hood XM2S-0911 Section 4-3 Wiring 4-3 Wiring Use only shielded RS-232C cable. Standard Connections F150 Signal name External device Pin Pin Signal ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z124-e1-01b_f150.pdf

マニュアル
PDF[Z130-E1-01] F400-C10E/C15E Color Vision Sensor Se...
... pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 4-2 Model No. Plug XM2A-0901 Hood XM2S-0911 Wiring Use only shielded RS-232C cable. Standard Connections F400 Signal name External device Pin Pin * * * * * Shield 20 Signal name Section Connection...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z130-e1-01_f400.pdf

マニュアル
PDF[Z132-E1-03] F150-C1[]E-2(-DRT) Vision Sensor Setu...
... pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 32 Model No. Plug XM2A-0901 Hood XM2S-0911 Section 4-3 Wiring 4-3 Wiring Use only shielded RS-232C cable. Standard Connections F150 Signal name External device Pin Pin Signal ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z132-e1-03_f150-c1_e-2(-drt).pdf

マニュアル
PDF[Z134-E1-04] F150-C1[]E-2(-DRT) Vision Sensor Expe...
... Run mode, will continue until all of the data has been output, even if the mode is changed. Data output will not be interrupted. 2. A timeout error will occur if there is no response from the computer within the set time when RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z134-e1-04_f150-c1_e-2(-drt).pdf

マニュアル
PDF[Z135-E1-01] F400-C10 Color Vision Sensor Operatio...
... and measurement results can be output. Measurement Commands I/O via the RS-232C Port F400 Computer Input command Perform measurement *The BUSY terminal turns ON while a measurements are being performed. Output result Receive result Note When RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z135-e1-01_f400.pdf

マニュアル
PDF[Z136-E1-01] V530-R150 2-Dimensional Code Reader O...
...-0911 Pin 38 Model No. Plug Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Section 4-1 Specifications 4-1-2 Wiring Only use a shielded RS-232C cable. Standard Connections V530-R150 Signal External device Pin Pin Signal Shield Connections for RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z136-e1-01_v530-r150.pdf

マニュアル
PDF[Z140-E1-02] V530-R150E-2/R150EP-2 2-Dimensional C...
...-0911 Pin 38 Model No. Plug Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Section 4-1 Specifications 4-1-2 Wiring Only use a shielded RS-232C cable. Standard Connections V530-R150 Signal External device Pin Pin Signal Shield Connections for RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z140-e1-02_v530-r150e-2_-r150ep-2.pdf

マニュアル
PDF[Z141-E1-03] F150-3 Vision Sensor Manual 1: Setup ...
... pin numbers and names are shown below. Pin 1 Signal FG (GND) Name Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 36 Model No. Plug XM2A-0901 Hood XM2S-0911 Z141-E1-03.book Page 37 Monday, July 24, 2006 5:16 PM Section 4-2 Wiring 4-2 Wiring Use only shielded ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z141-e1-03_f150-3.pdf

マニュアル
PDF[Z142-E1-02B] F150-3 Vision Sensor Manual 2: Exper...
.... Data output will not be interrupted. Measurement Commands I/O via RS-232C Port F150 Computer Input command Perform measurement *The BUSY terminal turns ON while a measurements are being performed. Output result Receive result Note When RC/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z142-e1-02b_f150-3.pdf

マニュアル
PDF[Z155-E1-02] V530-R150E(P)-3 2-Dimensional Code Re...
...-0911 Pin 48 Model No. Plug Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Section 4-1 Specifications 4-1-2 Wiring Only use a shielded RS-232C cable. Standard Connections V530-R150 Signal External device Pin Pin Signal Shield Connections for RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z155-e1-02_v530-r150e-3_r150ep-3.pdf

マニュアル
PDFz906-e1-11_ne1a-scpu01_02.pdf
... Input Monitor • Local Output Monitor • When the I/O type of a Target I/O is Target IN, data for communications between this Unit and a Safety Slave performing DeviceNet Safety communications can be included in the I/O data. IMPORTANT When connected to an OMRON ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z906-e1-11_ne1a-scpu01_02.pdf

商品情報
ネットワーク通信ユニット - FA用語辞典 | オムロン制御機器
...コントローラ Controller Linkユニット、SYSMAC LINKユニット、EthernetユニットなどのFINSメッセージ通信が可能な「CPU高機能ユニット」を指す。CS/CJシリーズ用DeviceNetユニットも含む。複数台装着する場合、ルーチングテーブルの自ネットワークテーブルに登録する必...

https://www.fa.omron.co.jp/guide/glossary/meaning/3761.html

商品情報
バッテリバックアップ - FA用語辞典 | オムロン制御機器
...当する商品カテゴリ プログラマブルコントローラ RAM内のデータが、バッテリによって、バックアップされること。CS/CJシリーズCPUユニットの場合、ユーザプログラム、パラメータエリア、I/Oメモリエリア。 FAシステム機器 プログラマブル...

https://www.fa.omron.co.jp/guide/glossary/meaning/3762.html

商品情報
ラックNo. - FA用語辞典 | オムロン制御機器
...> プログラマブルコントローラ> ラックNo. ラックNo. 該当する商品カテゴリ プログラマブルコントローラ CS/CJ、CVM1/CVシリーズのようなフリーチャネル方式のI/O割付における、各ラック(装置)ごとの番号をいう。 FAシステム機器 プログラ...

https://www.fa.omron.co.jp/guide/glossary/meaning/3768.html

商品情報
CPS - FA用語辞典 | オムロン制御機器
...ラマブルコントローラ> CPS CPS 該当する商品カテゴリ プログラマブルコントローラ Component Profile Sheetの略。CX-One内でのCS/CJ/CPシリーズユニット/各種コンポーネントの定義情報。CX-Programmer のI/Oテーブルでは、...

https://www.fa.omron.co.jp/guide/glossary/meaning/3883.html

商品情報
SYSBUSリレー - FA用語辞典 | オムロン制御機器
...ローラ SYSBUSリモートI/O親局ユニットの下に接続されたリモートI/O子局装置を割り付けるためのリレーエリア。CSシリーズにある。 FAシステム機器 プログラマブルコントローラ SYSBUSリレー 製品に関するFAQ 技術解説 FA用語辞典 ページ...

https://www.fa.omron.co.jp/guide/glossary/meaning/3929.html

商品情報
シリアルゲートウェイ - FA用語辞典 | オムロン制御機器
...プロトコルに自動的に変換して、シリアル通信上に流す機能。FINSコマンドを、CompoWay/F、上位リンクFINS、またはModbusに変換できる。CS/CJシリーズCPUユニット ユニットVer.3.0以降、シリアルコミュニケーションボード/ユニット ユニットVer.1.2以降の...

https://www.fa.omron.co.jp/guide/glossary/meaning/64.html

商品情報
プログラマブルコントローラ 用語解説 - 技術解説 | オムロン制御機器
...中断し、優先的に実行されます。 (PLCの機種により「割込タスク」を「割込プログラム」と表現する場合もありますが、本書ではCS/CJシリーズで使用される「割込タスク」の表現で説明します。) 例えば、CS/CJシリーズの場合、この割込タスクとして電断...

https://www.fa.omron.co.jp/guide/technicalguide/26/129/

商品情報
光伝送機器 補足説明 - 技術解説 | オムロン制御機器
...用接地またはアース 2 SD TXD BA Transmitted Data 送信データ DTE→ 3 RD RXD BB Received Data 受信データ ← DCE 4 RS RTS CA Request to Send 送信要求 DTE→ 5 CS CTS CB Clear to Send 送信可 ← DCE 6 DR DSR CC Data Set Ready データセットレディ 7 SG SG AB Signal Ground 信号用接地または共通アース - 8 CD DCD CF Received Line Signal Detector デ...

https://www.fa.omron.co.jp/guide/technicalguide/52/158/