ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 56941 件が検索されました。(1101 - 1120件を表示)
マニュアル
PDF[V064-E1-02] NT31-ST121(B)-EV2, NT31C-ST141(B)-EV2...
...case characters. When specifying a command, write those parts denoted in upper case without modification, for those parts denoted in lower case, write the numeric values (BCD or hexadecimal) or character string for parameters as ASCII character strings. Parts in square brackets, such as [ESC] and [...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v064-02_nt31_nt31c_nt631_nt631c.pdf

マニュアル
PDF[V069-E1-03] NT21, NT31, NT631 Programmable Termin...
...case characters. When specifying a command, write those parts denoted in upper case without modification, for those parts denoted in lower case, write the numeric values (BCD or hexadecimal) or character string for parameters as ASCII character strings. Parts in square brackets, such as [ESC] and [...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v069-e1-03_nt21_nt31_nt631.pdf

マニュアル
PDF[V085-E1-07] NS5, NS8, NS10, NS12, NS15 Programmab...
...XW2Z-S002 Omron product Cable length 2m, 9 pin⇔9 pin 39 3-3 Communications procedures 3-3-1 Memory Link Commands Command/response formats are as mentioned below. • Read/write/change notify command ESC • *D SUM ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v085-e1-07_ns15_12_10_8_5.pdf

マニュアル
PDF[V091-E1-01] NT-series Programmable Terminal User'...
... given in uppercase letters as is and replace lowercase letters with ASCII text strings to specify the numeric values of the parameters (BCD or hexadecimal) or the text strings for parameters. Any text given in square brackets [ ], however, represents one control code, such as ESC or ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v091-e1-01_nt20.pdf

マニュアル
PDF[V092-E1-13] NS(J)5, NS(J)8, NS(J)10, NS(J)12, NS1...
...Stop bit: Set the same as for the communication setting's Stop Bits of the PT. Transmission speed: Set the same as for the communication setting's Comm. Speed of the PT. Sumcheck: ON (YES) Transmission control procedure: Form1 (without ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v092-e1-13_ns_nsj_nsh.pdf

マニュアル
PDFv237-e1-04_ws02-sptc1-v2.pdf
...-DD hh:mm:ss.ms The nanoseconds at which recording was performed. The value is given in nanoseconds. An index number started from 1 when recording is started. The 5th and later fields contain the sampling data in order. A line feed code, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v237-e1-04_ws02-sptc1-v2.pdf

マニュアル
PDFv400-r1series(menusheet)_inst-5319182-1b%20.pdf
...しない 2of5 C/D無効 2of5 C/D転送するトリガ読取単発読取 2秒間 2回(照合1 回) 9600bps 8bit なし 1bit なし CR なし無限ノープロトコル方式処理なしデコード後 LED点灯時間 0.2s 有効最大負論理(Lアクティブ) 出力するトリガ同期方式、正論理(Hアク...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v400-r1series(menusheet)_inst-5319182-1b .pdf

マニュアル
PDF[9048275-5A] V500-R521B2/R521C2 Compact Laser Bar ...
... Method AND Redundancy Commu- Communication Rate 9600bps nication Condition Data Length 8 bits Parity No Parity Stop Bit 1 bits Commu- Header nication Settings Footer Detail for NW-7 (*) Not check CD N/A ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v500-r521-b2_r521c2(menusheet)_inst-9048275-5a.pdf

マニュアル
PDF[1640781-4A] V500-R521B2/521C2 超小型レーザバーコードリーダ 取扱説明...
...19200bps ※CODE128 (EAN128含む) 読取り禁止 ※ST/SP 転送 NW−7 詳細 2. 読取り桁数内 容 あり (BUSY/ READY) なし フッタ CR 桁数の転送 転送しない RS/CS制御 なし CS待ち時間 無限 通信プロトコル ノープロトコル方式 ACK/NAK待ち時間 無限 桁数指定B (注1) 負論理 (Lアクティブ) READ ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v500-r521b2_521c2(menusheet)_inst-1640781-4a.pdf

マニュアル
PDFv520-r221fh_sh(menusheet)%20_inst-1124215-9c.pdf
...ープロトルコモード C020 ACK/NAKモード C021 *2回 ユーザ選択2byte (直後に数字を読ます) C129 4段 通信手順 CR 連続一致回数 パリティ フッタ︵ポストアンブル︶ C131 データ出力モード *ETX Y003 *単発 C114 C005 C116 *外部トリガ *STX 115200bps NONE (無し) NAK 3回 C138 C111 C110 C006 ACK *有効 C019...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v520-r221fh_sh(menusheet) _inst-1124215-9c.pdf

マニュアル
PDF[1122981-0D] V520-R221FH/R221SH バーコードリーダ 取扱説明書
...度範囲外形寸法 ヘッダ:STX,ヘッダ無し,ユーザ指定1Byteから選択してください。 (工場出荷設定はSTXです。 ) フッタ:ETX,CR,ユーザ選択1Byteまたは2 B y t e か ら 選 択 し て く だ さ い 。 ( 工 場 出 荷 設 定 は E T X で す 。 ) *1 機能設定方法 使用環境 安全上の要点...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v520-r221fh_sh_inst-1122981-0d.pdf

マニュアル
PDF[W130-E1-05] C200H-CPU01-E/CPU03-E/CPU11-E Program...
...B VT ESC + ; K [ k { + ; K [ k { 1100 C FF FS , < L \ l | , < L \ l | 1101 D CR GS Ć = M ] m } Ć = M ] m } 1110 E S0 RS . > N ^ n « . > N ^ n 1111 F S1 US / ? O _ o ~ / ? O _ o ~ 343 Glossary address The location in memory where data is stored. For data areas, an address consists of a two-letter data area designation and a number that designates the word and/or bit location. For the UM area, an address designates the instruction location (UM area). In the FM area, the address designates the block location, etc. allocation...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w130-e1-05_c200h-cpu01-e_03-e_11-e.pdf

マニュアル
PDF[W140-E1-04] C1000H, C2000H Programmable Controlle...
...B VT ESC + ; K [ k { + ; K [ k { 1100 C FF FS , < L \ l | , < L \ l | 1101 D CR GS Ć = M ] m } Ć = M ] m } 1110 E S0 RS . > N ^ n « . > N ^ n 1111 F S1 US / ? O _ o ~ / ? O _ o ~ 369 Glossary address The location in memory where data is stored. For data areas, an address consists of a two-letter data area designation and a number that designates the word and/or bit location. For the UM area, an address designates the instruction location (UM area). In the FM area, the address designates the block location, etc. allocation...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w140-04_c1000h_c2000h.pdf

マニュアル
PDF[W143-E1-07] C200H-LK, C500-LK, 3G2A5-LK, 3G2A6-LK...
...FORCED SET/RESET CANCEL Not Valid Valid Valid All: C120, C200H/HS/ HX/HG/HE, C500, C1000H, C2000H MM PC MODEL READ Valid Valid Valid All: C120, C200H/HS/ HX/HG/HE, C500, C1000H, C2000H CR DM AREA HIGH-SPEED READ Valid Valid Valid C1000H, C2000H XZ ABORT and INITIAL (command only) Valid Valid Valid All: C120, C200H/HS/ HX/HG/HE, C500, C1000H, C2000H IC Undefined command (response only) Valid Valid Valid All: C120, C200H/HS/ HX/HG/HE, C500, C1000H, C2000H EX TRANSMIT Valid Valid Not valid C200HS Varies Unprocessed command (response only) Valid Valid Valid All: C120, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w143-07_c200h-lk_c500-lk_3g2a6-lk.pdf

マニュアル
PDF[W149-E1-02] C1000HF Programmable Controller Opera...
...(68) CD CB R Operands Compares 1-channel binary value (CD) with 16 ranges in comparison table (CB: First channel of comparison table). If value falls within any ranges, corresponding bits of result channel (R) set. Lower limit Upper limit ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w149-02_c1000hf.pdf

マニュアル
PDF[W174-E1-07] C1000H-SLK11/SLK21-V1, C200HW-SLK13/S...
... can be assembled using the S3200-CAK1062 by adding the JRFK-57PWS (made by Sumitomo Electric Industries, Ltd.). Coaxial-type Units Name Specifications Model BNC Connector Crimp-on connector. BNC-P-5C-CR10-B Crimping Tool Attaches the connector. ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w174-e1-07_c200hw_slk___c1000h_slk__-v1.pdf

マニュアル
PDF[W186-E1-04] C500-ASC04 ASCII Unit Operation Manua...
...The default value for both and is 10. The AUTO Command can be canceled by entering CTRL+C. If an already existing line number is specified, an asterisk (*) is displayed immediately after the line number. If a new line number is input followed by a ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w186-04_c500-asc04.pdf

マニュアル
PDF[W194-E1-02] CV500, CV1000, CV2000 Programmable Co...
...thesamemeaning. Anerrorinthewayinwhichaprogramiswritten.Syntaxerrorscaninclude `spelling'mistakes(i.e.,afunctioncodethatdoesnotexist),mistakesinspecifyingoperandswithinacceptableparameters(e.g.,specifyingread-onlybitsa$a destination),andmistakesinactualapPlicatjonofinstructions{e.9.,acalltoa subroutinethatdoesnotexist). ThearrangementinwhichUnitsinaSystemareconnected.Thistermrefersto theconceptualarrangementandwiringtogetherofallthedevicesneededto comprisetheSystem.InOMRONterminology,systemconfigurationisusedto describethearrangementandconnectionoftheUnitscomprisingaControlSys・ temthatincludesoneormorePCs, Anerrorgeneratedbythesystem,asopposedtooneresultingfromexecutionof aninstruCtiOndeSignedtogenerateanerrOr. Anerrormessagegeneratedbythesystem,asopposedtooneresultingfrom executionotaninstructiondeSignedtogenerateameSSage. Thecodecomprisinganasteriskandacarriagereturn(★...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w194-e1-02_cv500_cv1000_cv2000.pdf

マニュアル
PDF[W195-E1-08] CV500, CV1000, CV2000, CVM1 Programma...
... or more times per minute. Countermeasure Examples When switching an inductive load, connect a surge protector, diodes, etc., in parallel with the load or contact as shown below. Circuit Current AC DC Yes Power supply Inductive load ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w195-e1-08_cv500_1000_2000_cvm1.pdf

マニュアル
PDF[W196-E1-02] CV500-ZS3AT1-EV2/ZS5AT1-EV2 CV Suppor...
... one resulting from execution of an instruction designed to generate a message. terminal instruction An instruction placed on the right side of a ladder diagram that uses the final execution conditions of an instruction line. terminator The code comprising an asterisk and a carriage return (* ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w196-e1-02a_cv500-etn01.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。