全文検索:全 56941 件が検索されました。(1181 - 1200件を表示)
マニュアル
PDF[Z217-E1-01] V700-L12 ID Link Unit User's Manual
...Setting Contents Command 9,600 bps (Use initial setting.) Data length 8 bits (Use initial setting.) Parity Even L3 Stop bits 1 bit (Use initial setting.) Header None (Use initial setting.) Footer CR (Use initial setting.) RS/CS control None P0 Read failure processing Sends ?[...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z217-e1-01_v700-l12.pdf

マニュアル
PDFz219-e1-05_v600-chud_ch1d-v2_ch1d-psi.pdf
... frame (including the terminator) consists of up to 4,106 characters for commands and 4,102 characters for responses. 1 frame Command and Response Format Section 3 Command code × Data × × Terminator × 2 × ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z219-e1-05_v600-chud_ch1d-v2_ch1d-psi.pdf

マニュアル
PDF[Z221-E1-01] V680-CA1D/CA2D/H01/D1KP58HT Heat-resi...
...Sending the message data “OMRON” from Controller No. 2. Command Command code Controller No. @ 0 2 T Message data O S R M Terminator FCS O N 1 * 4 CR 2 5 2 2 Command code Message data FCS Terminator 3 Response Controller No. @ 0 2 T O S R M 2 3 O N 1 5 * 4 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z221-e1-01_v680-ca_d_h01_d1kp58ht.pdf

マニュアル
PDF[Z224-E1-01] ZUV Series Smart Curing System User's...
... the controller version) p.3-20 DATA BIT 8BIT 8BIT, 7BIT p.4-9 PARITY NON NON, ODD, EVEN STOP BIT 1BIT 1BIT, 2BIT BAUD RATE 38400 9600, 19200, 38400, 57600, 115200 DELIMITER CR+LF CR, LF, CR+LF EMISSION OFF ON, OFF CH OUT OFF ON, OFF BUZZER M OFF, L, M, H p.3-18 ECO OFF ON, OFF p.3-18 COLOR MARINE BLUE MARINE BLUE, GRASS GREEN ORANGE PEEL, STYLISH GRAY, SALMON PINK, NIGHTMARE LANGUAGE – JAPANESE, ENGLISH Section 3 SETUP BUTTON LOCK Default Value p.3-18 p.3-19 ZUV User’s Manual 3-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z224-e1-01_zuv.pdf

マニュアル
PDF[Z225-E1-01] ZUV Series Smart Curing System Quick ...
...BUTTON LOCK 3. BUZZER 4. DISPLAY 5. LANGUAGE 6. ALL CLEAR 7. VERSION Set the system environment. Setting value 8 BIT, 7 BIT NON, ODD, EVEN 1BIT, 2BIT 9600,19200,38400,57600,115200 CR,LF,CR+LF When [BUTTON LOCK] is selected: 1. EMISSION 1.OFF 2. CH OUT 2.ON When [BUZZER] is selected: 1.OFF 2.L 3.M 4.H When [DISPLAY] is selected: 1. ECO 2. COLOR When [ECO] is selected: 1.OFF 2.ON When [COLOR] is selected: 1. MARINE BLUE 2. GRASS GREEN 3. ORANGE PEEL When [LANGUAGE] is selected: 4. STYLISH GRAY 5....

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z225-e1-01_zuv.pdf

マニュアル
PDF[Z228-E1-03] V400-H111/H211 Handheld 2D Code Reade...
...Introduction How to Use This Manual Page Format Describes the settings. 9,600*, 19,200, or 38,400 None*, odd, or even 77 bits or 8 bits* 1sbit* or 2 bits None*, 02 , or 1B * ETX, 0A LF, 0D CR...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z228-e1-03_v400-h111_h211.pdf

マニュアル
PDF[Z234-E1-01] ZEN-10C3AR-A-V2/10C3DR-D-V2 Programma...
... is 5 times per minute or higher. Countermeasure Examples When switching an inductive load, connect an surge protector, diodes, etc., in parallel with the load or contact as shown below. Circuit Current C R Power supply Inductive load ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z234-e1-01_zen-10c3_r-_-v2.pdf

マニュアル
PDF[Z235-E1-02] V750-BA50C04-US, V740-HS01CA/HS01LA R...
... command line I/F. Command frame has a Command Code area to control the R/W and Command Data area that is used with Command Code. Terminator that indicates the end of the frame is [LF]. RS-232C requires a start code [SOH], check data, and [...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z235-e1-02_v750-ba50c04-us.pdf

マニュアル
PDF[Z240-E1-05] ZFV-C Smart Sensors (with Ultra-High-...
...PARITY OFF OFF, ODD, EVEN p.104 p.104 STOP BIT 1 1, 2 p.104 BAUDRATE 38400 9600, 19200, 38400, 57600, 115200 p.104 NODE 0 0 to 16 DELMIT CR CR, LF, CR+LF p.104 p.104 WHITE BALANCE - - p.102 ALL CLEAR - - p.102 MEAS CLEAR - - p.103 LANGUAGE - ENGLISH, JAPANESE p.103 VERSION - - p.103 MODE SWITCH LOCK OFF LOCK OFF, LOCK ON p.107 KEY LOCK OFF LOCK OFF, LOCK ON p.107 TEACH IN LOCK OFF LOCK OFF, LOCK ON p.107 PASS NUMBER 0000 0~9999 p.107 OUTPUT (*8) EACH ALL, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z240-e1-05_zfv-c.pdf

マニュアル
PDF[Z242-E1-04] V400-F050/F250/F350 2D Code Reader Us...
...Details Input Set the basic input format items. Output Set the basic output format items. None*/STX/ESC Select the symbol that indicates the beginning (header) of the command format. No symbol will be selected if [None] is selected. Suffix ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z242-e1-04_v400-f050_f250_f350.pdf

マニュアル
PDF[Z244-E1-01] ZFV-C Smart Sensors Non-procedural Co...
.... For a description of each command, refer to "List of Non-procedural Commands." •SYSGET/DATAGET/BANKGET command The returned value consists of left-aligned characters indicating the acquired value and a delimiter. Example: The returned value is -30 mm. - 3 0 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z244-e1-01_zfv-c.pdf

マニュアル
PDF[Z250-E1-02] ZG Series Smart Sensor (2D Profile Me...
...) are available for extending the installation distance between the Sensor and the Controller. Digital equalizer ZG-XEQ Cable for Sensor : 0.5 m (2 m) (flexible cable) ZG User’s Manual Digital equalizer ZG-XEQ Extension cable ZG-XC__...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z250-e1-02_zg.pdf

マニュアル
PDF[Z251-E1-04] ZFX-C10 Smart Sensor (Vision Sensor w...
...The following values can be output when expressions are set. Item Description Message Judgment result The judgment result is output. (0:OK, -1:NG, -2: not measured) Judge (JG) Correlation The degree of match between the measurement image and model Correlation (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z251-e1-04_zfx-c10.pdf

マニュアル
PDF[Z252-E1-03] ZFX-C10 Smart Sensor (Vision Sensor w...
... USB interface. Synchronization method Start-stop Transmission code ASCII (Binary format can be selected only when outputting measurement values set at [Setup] - [Support] - [Calculation] - [Data].) Communication speed USB2.0-compliant Data length - Parity - Stop bit - Delimiter ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z252-e1-03_zfx-c10.pdf

マニュアル
PDF[Z253-E1-02] V500-R521B2/R521C2 Bar Code Reader Us...
.... Section 4 Creating Setting Files Using the 2DCR Configear ■ Open 9,600*, 19,200, or 38,400 None*, odd, or even * 77 bits or 8 bits 1sbit* or 2 bits None*, 02 , or 1B * ETX, 0A LF, 0D CR , or 0D0A ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z253-e1-02_v500-r521b2_r521c2.pdf

マニュアル
PDF[Z260-E1-04] ZR-RX40 Portable Multi Logger User's ...
...-RX40_UM_E.book 70 ページ 2009年12月11日 金曜日 午前10時58分 (5) Interface settings This menu is used to specify conditions for PC connection. Settings Selections available New Line code CR...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z260-e1-04_zr-rx40.pdf

マニュアル
PDF[Z262-E1-09A] V680-HA63A/HS5[]/HS6[]/H01-V2/D1KP[]...
... the data retention time *1. High temperatures are those exceeding 125°C up to 250°C. • Resetting the data retention time 1.Reading data from the RF tag addresses 0010Hex to 0015Hex. Command : RDSTH100100006*[...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z262-e1-09a_v680.pdf

マニュアル
PDF[Z264-E1-09] ZFX-C Smart Sensor (Vision Sensor wit...
...The following values can be output when expressions are set. Item Description Message Judgment result The judgment result is output. (0:OK, -1:NG, -2: not measured) Judge (JG) Correlation The degree of match between the measurement image and model Correlation (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z264-e1-09_zfx-c.pdf

マニュアル
PDF[Z265-E1-06A] ZFX-C Smart Sensor (Vision Sensor wi...
... USB interface. Synchronization method Start-stop Transmission code ASCII (Binary format can be selected only when outputting measurement values set at [Setup] - [Support] - [Calculation] - [Data].) Communication speed USB2.0-compliant Data length - Parity - Stop bit - Delimiter ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z265-e1-06a_zfx-c.pdf

マニュアル
PDF[Z276-E1-01A] V400-R1CF/R1CS Multi-code Reader Use...
...Setting content Command 9600 bps (Factory default setting) Data length 8 bits (Factory default setting) Parity None (Factory default setting) Stop bit 1 bit (Factory default setting) Header None (Factory default setting) Footer ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z276-e1-01a_v400-r1cf_r1cs.pdf