ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 57627 件が検索されました。(1201 - 1220件を表示)
マニュアル
PDF[Z262-E1-09A] V680-HA63A/HS5[]/HS6[]/H01-V2/D1KP[]...
... the data retention time *1. High temperatures are those exceeding 125°C up to 250°C. • Resetting the data retention time 1.Reading data from the RF tag addresses 0010Hex to 0015Hex. Command : RDSTH100100006*[...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z262-e1-09a_v680.pdf

マニュアル
PDF[Z264-E1-09] ZFX-C Smart Sensor (Vision Sensor wit...
...The following values can be output when expressions are set. Item Description Message Judgment result The judgment result is output. (0:OK, -1:NG, -2: not measured) Judge (JG) Correlation The degree of match between the measurement image and model Correlation (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z264-e1-09_zfx-c.pdf

マニュアル
PDF[Z265-E1-06A] ZFX-C Smart Sensor (Vision Sensor wi...
... USB interface. Synchronization method Start-stop Transmission code ASCII (Binary format can be selected only when outputting measurement values set at [Setup] - [Support] - [Calculation] - [Data].) Communication speed USB2.0-compliant Data length - Parity - Stop bit - Delimiter ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z265-e1-06a_zfx-c.pdf

マニュアル
PDF[Z276-E1-01A] V400-R1CF/R1CS Multi-code Reader Use...
...Setting content Command 9600 bps (Factory default setting) Data length 8 bits (Factory default setting) Parity None (Factory default setting) Stop bit 1 bit (Factory default setting) Header None (Factory default setting) Footer ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z276-e1-01a_v400-r1cf_r1cs.pdf

マニュアル
PDF[Z283-E1-03] ZR-RX70 Portable Multi Logger User's ...
... switches with ENTER key. 3 Selections available USB ID 0 to 9 IP Address 0 to 255. 0 to 255. 0 to 255. 0 to 255 Detailed Settings New Line Code SETTINGS AND MEASUREMENT Setting CR+LF, LF, CR USB ID 0 to 9 IP Address 0 to 255. 0 to 255. 0 to 255. 0 to 255 Subnet Mask 0 to 255. 0 to 255. 0 to 255. 0 to 255 Port Number 1024 to 65535 Gateway 0 to 255. 0 to 255. 0 to 255. 0 to 255 DNS Address 0 to 255. 0 to 255. 0 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z283-e1-03_zr-rx70.pdf

マニュアル
PDF[Z290-E1-05] FZ3 Series Vision Sensor User's Manua...
...[8] [OFF] Odd Even Adjust to the PC communication specifications. [1 ] 2 Xon/Xoff Flow control is performed with software. Data is sent according to the Xon/Xoff codes from external devices. ● ● ● Timeout [s] [...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z290-e1-05_fz3.pdf

マニュアル
PDF[Z291-E1-05] FZ3 Series Vision Sensor Processing I...
.... 1. 50 In the "Model parameter" area, select the search mode, then specify a value for each item for Search FZ3 Processing Items List Manual that mode. 2 Set value [factory default] Measurement Setting item Description [...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z291-e1-05_fz3.pdf

マニュアル
PDF[Z302-E1-03A] FQ Vision Sensor User's Manual
...X Position X This is the X coordinate of the position −99999.9999 to 99999.9999 where the model was found. Y Position Y This is the Y coordinate of the position −99999.9999 to 99999.9999 where the model was found. ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z302-e1-03a_fq.pdf

マニュアル
PDF[Z304-E1-03] ZR-RX45 Data Logger User's Manual
..., they can be called up easily by simply switching the user. ZR-RX45 User’s Manual Setting Menus 95 (5) Interface settings This menu is used to specify conditions for PC connection. Setting Selections available Selections available New Line code ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z304-e1-03_zr-rx45.pdf

マニュアル
PDF[Z314-E1-05] FQ-MS12[] Specialized Vision Sensor f...
...2: No judgement (not measured), 0: Judgement is OK, −1: Judgement is NG, −13: Teaching not performed error, −14: Figure not registered error, −15: Out of range error C Count This is the number of models found. 0 to 32 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z314-e1-05_fq-ms12.pdf

マニュアル
PDF[Z318-E1-02B] FZ4 Series Vision Sensor User's Manu...
... mode 0 rotation With rotation 0 endAngle Upper limit of the rotation angle 180 startAngle Lower limit of the rotation angle -180 angleSkip Skipping angle 5 smartMode Smart mode 1 stability Stab.(CR) 12 accuracy Prec. 2 searchSpeed Stab.(SH) 3 referencePosX Reference X 0 referencePosY Reference Y 0 detectionPosX Detection point X 0 detectionPosY Detection point Y 0 subPixel Sub-pixel 0 candidateLevel Candidate Point Level 70 upperX Upper limit of measure X 99999.9999 lowerX Lower limit of measure X -99999.9999 upperY Upper limit of measure Y 99999.9999 lowerY Lower limit of measure Y -99999....

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z318-e1-02b_fz4.pdf

マニュアル
PDF[Z319-E1-02] FZ4 Series Vision Sensor Processing I...
.... 1. In the "Model parameter" area, select the search mode, then specify a value for each item for FZ4 Processing Items List Manual Search 59 that mode. 2 Measurement Setting item Set value [factory default] Description [...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z319-e1-02_fz4.pdf

マニュアル
PDF[Z322-E1-05] ZW-C1[]T Confocal Fiber Type Displace...
... length Sets the data length. 8 bits (default value), 7 bits Parity Sets the parity bit (error detection sign). None (default value), odd, even Stop bit Sets the stop bit. 1bit (default), 2bit Delimiter Sets the delimiter (data delimiter). ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z322-e1-05_zw-c1_t.pdf

マニュアル
PDF[Z323-E1-01] ZW Series Displacement Sensor (Confoc...
...IP1: 1 to 233 IP2: 0 to 255 IP3: 0 to 255 IP4: 1 to 254 Subnet mask SUB1.SUB2.SUB3.SUB4 SUB1: 0 to 255 SUB2: 0 to 255 SUB3: 0 to 255 SUB4: 0 to 255 Delimiter CR, LF, CR+LF Analog output Voltage/Current output Sensor Head calibration Calibrates the Sensor Head. Refer to User's Manual. Calibrations conducted in an inappropriate environment may lead to failures in measurement. Timing reset Executes a timing reset. System information This provides four types of system information. Controller version Displays the version of the controller. Controller MAC address Displays the ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z323-e1-01_zw.pdf

マニュアル
PDF[Z328-E1-01] Z5FP-MC10/MC15 LCD Seal Profile Senso...
... as shown in the following table.Use the default settings under normal circumstances. Setting communication specifications p.195 Item Setting value Baud rate 38400 (bps) Data length 8 (bit) Parity None Stop bits 1 (bit) Delimiter ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z328-e1-01_z5fp-mc10_mc15.pdf

マニュアル
PDF[Z332-E1-07] ZW-CE1[]T Confocal Fiber Type Displac...
... length Sets the data length. 8 bits (default value), 7 bits Parity Sets the parity bit (error detection sign). None (default value), odd, even Stop bit Sets the stop bit. 1bit (default), 2bit Delimiter Sets the delimiter (data delimiter). ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z332-e1-07_zw-ce1_t.pdf

マニュアル
PDF[Z359-E1-03] MX-Z2000G Series Fiber Laser Marker ...
...f g h i j k l m n o Code A NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI Code B ` a b c d e f g h i j k l m n o Input p q r s t u v w x y z { | } ~ @D Code A DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US Code B p q r s t u v w x y z { | } ~ DEL Fiber Laser Marker MX-Z2000G series User’s Manual 2 - ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z359-e1-03_mx-z2000g.pdf

マニュアル
PDF[Z377-E1-06] MX-Z2000H series Fiber Laser Marker U...
...f g h i j k l m n o Code A NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI Code B ` a b c d e f g h i j k l m n o Input p q r s t u v w x y z { | } ~ @D Code A DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US Code B p q r s t u v w x y z { | } ~ DEL Fiber Laser Marker MX-Z2000H series User’s Manual (Z377)...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z377-e1-06_mx-z2000h.pdf

マニュアル
PDF[Z421-E1-02] FZ5 Series Vision System User's Manua...
... one record. The format for each record that is written to the log file is as follows: The four data items, the execution date and time, user name, input information, and output information, are delimited with semicolons. At the end of the record, a line feed (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z421-e1-02_fz5.pdf

マニュアル
PDF[Z422-E1-01] FZ5 Series Vision System User's Manua...
.... Xon/Xoff Flow control is performed with software. Data is sent according to the Xon/Xoff codes from external devices. 1 to 120 [5] Set the time in which a timeout error will occur. Flow control Timeout [s] Description • [...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z422-e1-01_fz5.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。