全 148 件が検索されました。(81 - 100件を表示)

  • マニュアル

    ...XSYSTEM-42 (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-27 (XUSR-22) M XSYSTEM-38 (XPND-25) XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) N AM1 O XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES2 P ES1 Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 Figure 4-16. E-Stop Circuit on XUSR and XFP Connectors 14608-000 Rev. L Hornet 565 Robot User's Guide 67 4.9 Installing User-Supplied Safety Equipment Key Meaning Key Meaning A ESTOP 24 V Source K Auto/Manual Output B Bulb, 6 V, ...

  • マニュアル

    ...XSYSTEM-42 (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-27 (XUSR-22) M XSYSTEM-38 (XPND-25) XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) N AM1 O XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES2 ES1 P Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 Figure 5-14. E-Stop Circuit on XUSR and XFP Connectors 09955-000 Rev. N Quattro User's Guide 97 5.11 Installing User-Supplied Safety Equipment Callout Description Callout Description A ESTOP 24 V Source K Auto/Manual Output B Bulb L T20 Pendant Enable...

  • マニュアル

    ...XSYSTEM-42 (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-27 (XUSR-22) M XSYSTEM-38 (XPND-25) XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) N AM1 O XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES2 P ES1 Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 Figure 5-16. E-Stop Circuit on XUSR and XFP Connectors 05173-060 M Viper 650/850 Robot with eMB-40/60R User's Guide 83 5.9 Installing User-Supplied Safety Equipment Key Meaning Key Meaning A ESTOP 24 V Source K Auto/Manual Output...

  • マニュアル

    ...XFP-7 ESTOPSRC XFP-1 5 Grn XFP-2 XFP-9 XFP-10 XFP-15 6 4 3 23 ES2 8 22 XUSER-14 XUSER-15 XUSER-7 XUSER-8 ES1 7 ES1 ES2 XUSER-2 XUSER-1 ES1 ESTOPSRC ES2 9 XUSER-21 XUSER-20 XUSER-4 XUSER-3 24 V 11 10 24 XFP-3 XFP-4 XFP-11 XFP-12 XUSER-16 XUSER-17 MM1 MM1 MM2 MM2 XUSER-9 XUSER-10 12 25 MM2 MM1 XUSER-23 XUSER-22 XUSER-6 13 XUSER-5 24 V XFP-5 26 XFP-6 14 XUSER-18 XUSER-19...

  • マニュアル

    ...XSYSTEM-42 (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-27 (XUSR-22) M XSYSTEM-38 (XPND-25) XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) N AM1 O XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES2 P ES1 Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 Figure 3-6. E-Stop Circuit on XUSR and XFP Connectors 24402-000 Rev C eCobra 600 and 800 Robots with EtherCAT 51 3.5 Installing User-Supplied Safety Equipment Key Meaning Key Meaning A ESTOP 24 VDC Source K Auto/Manual Output B Bulb, 6 ...

  • マニュアル

    ...XSYSTEM-42 (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-27 (XUSR-22) M XSYSTEM-38 (XPND-25) XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) N K O XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES2 ES1 P Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 Figure 3-6. E-Stop Circuit on XUSR and XFP Connectors 21861-000 Rev B Viper 650 and 850 Robot with EtherCAT 49 3.6 Installing User-Supplied Safety Equipment Key Meaning Key Meaning A ESTOP 24 VDC Source K Auto/Manual Output B Bulb, 6 ...

  • マニュアル

    ...XSYSTEM-42 (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-27 (XUSR-22) M XSYSTEM-38 (XPND-25) XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) N AM1 O XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES2 P ES1 Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 Figure 3-12. E-Stop Circuit on XUSR and XFP Connectors 22792-000 Rev. A iX3 565 Robot with EtherCAT User’s Manual 47 3.6 Installing User-Supplied Safety Equipment Key Meaning Key Meaning A ESTOP 24 VDC Source K Auto/Manual Output B Bulb, ...

  • マニュアル

    ... (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-38 (XPND-25) K AM1 XSYSTEM-27 (XUSR-22) M XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) O N XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES 2 P ES 1 Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 Figure 3-14. E-Stop Circuit on XUSR and XFP Connectors 22793-000 Rev. B iX4 650 H/HS and 800 H/HS Robot with EtherCAT User’s Manual (Cat. No. I656) 56 3.7 Installing User-Supplied Safety Equipment Key Meaning Key Meaning...

  • マニュアル

    ...Automatic Mode Status Outputs XUSR-23 XUSR-5 XMCP-11 XUSR-6 XUSR-22 XMCP-12 XUSR-18 XUSR-19 XUSR-8 XUSR-7 ES2 Force-Guided Relay Cycle Check Control Circuit ES1 ES1 Emergency Stop Status Outputs XUSR-20 XUSR-21 ES2 200 to 240 VAC High Power Input (External) Internal High Power SR1 SR2 XUSR Connections Use the information in the following table to understand the signals provided on the XUSR connector. 3-36 PIN 13 PIN 1 PIN 25 PIN 14 i4L Robots User's Manual (I658) 3 Installation Pins Description Additional Information 2, 15 Emergency stop ...

  • マニュアル

    ...Automatic Mode Status Outputs XUSR-23 XUSR-5 XMCP-11 XUSR-6 XUSR-22 XMCP-12 XUSR-18 XUSR-19 XUSR-8 XUSR-7 ES2 Force-Guided Relay Cycle Check Control Circuit ES1 ES1 Emergency Stop Status Outputs XUSR-20 XUSR-21 ES2 200 to 240 VAC High Power Input (External) Internal High Power SR1 SR2 XUSR Connections Use the information in the following table to understand the signals provided on the XUSR connector. PIN 13 PIN 1 PIN 25 PIN 14 i4L Robots with EtherCAT User's Manual (I659) 3-8 Installing Safety Equipment The XMCP connector provides access ...

  • マニュアル

    ...Automatic Mode Status Outputs XUSR-23 XUSR-5 XMCP-11 XUSR-6 XUSR-22 XMCP-12 XUSR-18 XUSR-19 XUSR-8 XUSR-7 ES2 Force-Guided Relay Cycle Check Control Circuit ES1 ES1 Emergency Stop Status Outputs XUSR-20 XUSR-21 ES2 200 to 240 VAC High Power Input (External) Internal High Power SR1 SR2 XUSR Connections Use the information in the following table to understand the signals provided on the XUSR connector. 3-38 PIN 13 PIN 1 PIN 25 PIN 14 i4H Robots User's Manual (I660) 3 Installation Pins Description Additional Information 2, 15 Emergency stop ...

  • マニュアル

    ...AM1 AM1 XMCP-4 Automatic Mode Status Outputs XUSR-23 XUSR-5 XMCP-11 XUSR-6 XUSR-18 XUSR-22 Muted Safety Gate XMCP-12 XUSR-19 XUSR-8 XUSR-7 ES2 ES1 ES1 Force-Guided Relay Cycle Check Control Circuit Emergency Stop Status Outputs XUSR-20 XUSR-21 ES2 200 to 240 VAC High Power Input (External) Internal High Power SR1 SR2 XUSR Connections Use the information in the following table to understand the signals provided on the XUSR connector. PIN 13 PIN 1 PIN 25 PIN 14 Pins 3-38 Description 1, 14 Emergency stop channel 1 input...

  • マニュアル

    ...PA Cable length (from master to converter) ≤ 20 m Cable length (from converter to sensor) ≤ 30 m and TC of 100 Ω or less and Pt of 10 Ω or less Power supply Class2, LPS, LIM and SELV or PELV, PS2 and ES1...

  • マニュアル

    ...XSYSTEM-42 (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-27 (XUSR-22) M XSYSTEM-38 (XPND-25) XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) N K O XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES2 P ES1 Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 図4-16. XUSRおよびXFPコネクタ上の非常停止回路 75 Hornet 565ロボットユーザーズマニュアル 14608-003 Rev. D 第4章: シス...

  • マニュアル

    ...XSYSTEM-42 (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-27 (XUSR-22) M XSYSTEM-38 (XPND-25) XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) N AM1 O XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES2 P ES1 Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 図5-15. XUSRおよびXFPコネクタ上の非常停止回路 09955-003 Rev D パラレルロボット Quattro 650H/650HS/800H/800HS ユーザーズマニュア...

  • マニュアル

    ...XSYSTEM-42 (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-27 (XUSR-22) M XSYSTEM-38 (XPND-25) XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) N AM1 O XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES2 P ES1 Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 図5-16. XUSRおよびXFPコネクタの非常停止回路 92 垂直多関節ロボットViper 650/850 eMB-60Rユーザーズマニュアル 05173-063 ...

  • マニュアル

    ...XSYSTEM-42 (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-27 (XUSR-22) M XSYSTEM-38 (XPND-25) XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) N AM1 O XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES2 P ES1 Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 図3-6. XUSRおよびXFPコネクタの非常停止回路 24402-003 Rev B スカラロボットeCobra 600/800 EtherCATタイプユーザーズマニュア...

  • マニュアル

    ...XSYSTEM-42 (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-27 (XUSR-22) M XSYSTEM-38 (XPND-25) XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) N AM1 O XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES2 P ES1 Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 図3-6. XUSRおよびXFPコネクタの非常停止回路 54 Viper 650/850 EtherCATタイプ 21861-003 Rev B 第3章: ロボットの据え付け キー 意...

  • マニュアル

    ...XSYSTEM-42 (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-27 (XUSR-22) M XSYSTEM-38 (XPND-25) XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) N AM1 O XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES2 ES1 P Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 図3-12. XUSRおよびXFPコネクタの非常停止回路 54 パラレルロボットiX3 565 EtherCATタイプユーザーズマニュアル 22792-003 ...

  • マニュアル

    ... (XUSR-23) XSYSTEM-30 (XUSR-6) XSYSTEM-38 (XPND-25) K AM1 XSYSTEM-27 (XUSR-22) M XSYSTEM-29 (XUSR-18) XSYSTEM-44 (XUSR-19) O N XSYSTEM-26 (XUSR-8) XSYSTEM-10 (XUSR-7) ES1 ES 2 P ES 1 Q XSYSTEM-25 (XUSR-20) ES2 XSYSTEM-40 (XUSR-21) R S SR1 SR2 図3-14. XUSRおよびXFPコネクタの非常停止回路 22793-003 Rev. B EtherCATタイプパラレルロボット iX4650H/650HS/800H/800HSユーザーズ...