全文検索:全 200 件が検索されました。(61 - 80件を表示)
マニュアル
PDF[V025-E1-02] NT610C-DT151[]-V[] Programmable Termi...
...Remarks XM2D-0901 9-pin type OMRON, for personal computer XM2A-0901 9-pin type OMRON, for NT610C body Connector hood XM2S-0911 9-pin type OMRON Cable AWG28X5P IFVV-SB Multicore shielded cable Fujikura, Ltd. CO-MA-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v025-02_nt610c.pdf

マニュアル
PDF[V028-E1-01] NT-ZA3PC-V2/ZA3DV-V2 Support Tool Ope...
...25-pin Made by OMRON XM2A-0901 9-pin Made by OMRON XM2S-2511 25-pin Made by OMRON XM2S-0911 9-pin Made by OMRON AWG28×5P IFVV-SB Multi-core shielded cable Made by Fujikura, Ltd. CO-MA-VV-SB 5P×28AWG Multi-core shielded cable Made by Hitachi, Ltd. 193 Connecting Cable Specifications Appendix A 9-pin Connector Personal computer Connector for peripheral devices on PT body Shielded wire Use the following recommended products when making the connecting cable. Model Remarks XM2D-0901 9-pin Made by OMRON XM2A-0901 9-pin Made by OMRON Connector hood XM2S-0911...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v028-01_nt-za3pc-v2_za3dv-v2.pdf

マニュアル
PDF[V034-E1-05] NT30, NT30C Programmable Terminal Ope...
...-pin, OMRON) - Connector hood: XM2S-0911 (9-pin type, OMRON) Prepare the cable recommended by OMRON. The recommended cables are indicated in the following table. Name Cable Type Remark AWG285P IFVV-SB Multiconductor shielded cable (FUJIKURA, Ltd.) CO-MA-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v034-05_nt30_nt30c.pdf

マニュアル
PDF[W258-E1-05] 3G2A5-AD00[]/DA00[], C500-AD101/AD501...
...Section 3-1 Specifications and General Information The following diagram shows the wiring when the same power supply is used for input points 1 through 4. Input device R: 25 kW +V 0V +V 0V +V 0V +VV 0V + R – + R – + R – + R – Shielded twisted-pair cable 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 +Voltage input +Current input Input point 1 – Input Shield +Voltage input +Current input – Input Input point 2 Shield +Voltage input +Current input – Input Input point 3 Shield +Voltage input +Current input – Input Input point 4 Shield...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w258-e1-05_3g2a5-ad_da_c500-ad_da.pdf

カタログ
PDF[-] CJ1W-SCU Data Sheet
...-E (manufactured by OMRON) or equivalent Recommended Cables UL2426 AWG28 × 5P IFS-RVV-SB (UL-approved, Fujikura Ltd.) AWG28 × 5P IFVV-SB (not UL-approved, Fujikura Ltd.) UL2426-SB (MA) 5P × 28AWG (7/0.127) (UL-approved, Hitachi Metals, Ltd.) CO-MA-...

https://www.fa.omron.co.jp/data_pdf/cat/cj1w-scu_ds_e_9_5_csm2151.pdf

カタログ
PDF[-] CJ1W-SCU データシート
...等品 推奨ケーブル UL2464 AWG28×5P IFS-RVV-SB (UL品) 藤倉電線製 AWG28×5P IFVV-SB(非UL品) UL2464-SB(MA)5P×28AWG(7/0.127) (UL品) 日立金属製 CO-MA-VV-SB 5P×28AWG(7/0.127) (非UL品) 線路長:15m以下 ご購入 当社販売店 または オムロンFAストア www.fa.omron.co.jp 11 CJ1W-SCU RS-422A/485ポートプロトコル通信方式 上...

https://www.fa.omron.co.jp/data_pdf/cat/cj1w-scu_ds_j_9_6.pdf

カタログ
PDFSeparate Amplifier Proximity Sensor with Adjustmen...
...14 13 12 to 24 V +V 9 4.7K ¼W Amplifier Unit Voltage load (logic circuit) To next stage Tr 0.0022 μ 14 13 Tr Remarks 4.7 K ¼W VV : 3V IC: 20 mA max. HFE: 50 mA max. VCED: 30 V min. 4.7 K ¼W Interface circuits −V (0 V) Solid-state circuit When connecting to a CMOS IC or TLL, provide an interface circuit as shown above and connect to the solid-state circuit in the next stage. 11 E2C/E2C-H Model E2C-AK4A Load E2C-AM4A Ta Relay output 2 DC load • ...

https://www.fa.omron.co.jp/data_pdf/cat/e2c_e2c-h_ds_e_9_6_csm445.pdf

カタログ
PDFアンプ分離近接センサ (ボリウムタイプ) E2C/E2C-H CSM_E2C_E2C-H_DS_J_...
...圧負荷 (ロジック回路) 次段へ Tr 0.0022μ 14 13 4.7K 1 − W 4 −V(0V) ( Tr 備考 − 4.7K W 4 VV:3V IC: 20mA以上 HFE: 50以上 VCED: 30V以上 ) インターフェース回路 無接点回路 C-MOS IC、TLLに接続する場合は、上図のようなインターフェース回路を設けて次段の無接点回路...

https://www.fa.omron.co.jp/data_pdf/cat/e2c_e2c-h_ds_j_9_11.pdf

マニュアル
PDF[2219498-9E] D4SL-N□□□□-□□ 電磁ロックセーフティ・ドアスイッチ 取扱説明書...
...Installez plutôt un autre système detemperature verrouillage (par exemple un Approximately 6.4W-0.27A D4SL-N |N/P/Q/R erriegelungseinrichtung (z. B. einenkann Riegel)Installieren zusätzlich zum Schalter oder ...

https://www.fa.omron.co.jp/data_pdf/mnu/d4sl-n_____-___inst-2219498-9e.pdf

マニュアル
PDF[2219499-7E] D4SL-N□□□□-□□N 電磁ロックセーフティ・ドアスイッチ 取扱説明...
...12 4 52 4 52 51 22 51 22 64 8 64 Lock M onitor Switch) Lock M onitor Switch) 3 Fig.3 3 Fig.3 (for D4SL-N for D4SL-N V VV (for D4SL-N for D4SL-N 9 ( ) 8 2-M4 2-M4 40±0.140±0.1 detection switch and and the the locklock monitor switch NC NC contacts closeclose when detection switch monitor switch contacts when the lock is necessary on safety. the lock is necessary on safety. 4). The 24VDC solenoid has has a polarity. (E1: (E1: Positive (+) polarity, E2: Negative (-) (-) 4). The 24VDC...

https://www.fa.omron.co.jp/data_pdf/mnu/d4sl-n_____-__n_inst-2219499-7e.pdf

マニュアル
PDF[E413-E1-02] E3X-ECT Sensor Communication Unit Ope...
...16 6YYY hex YY hex PDO-Length : 32 Bit PDO_1 Application objects 6TTT hex TT hex 5-4-3 Object A Object B Object D Object A 6UUU hex UU hex Object B 6VVV hex VV hex Object C 6YYY hex YY hex Object D 6ZZZ hex ZZ hex Object E Sync Manager PDO Assignment Settings A sync manager channel consists of several PDOs. The sync manager PDO assignment objects describe how these PDOs are related to the Sync Manager. The number of PDOs is given in sub-index 0 of the sync manager PDO assignment table. In this ...

https://www.fa.omron.co.jp/data_pdf/mnu/e413-e1-02_e3x-ect.pdf

マニュアル
PDF[E429-E1-12] E3NW-ECT EtherCAT® Digital Sensor Com...
...16 6YYY hex YY hex PDO-Length : 32 Bit PDO_1 Application objects 6TTT hex TT hex 5-4-3 Object A Object B Object D Object A 6UUU hex UU hex Object B 6VVV hex VV hex Object C 6YYY hex YY hex Object D 6ZZZ hex ZZ hex Object E Sync Manager PDO Assignment Settings A sync manager channel consists of several PDOs. The sync manager PDO assignment objects describe how these PDOs are related to the Sync Manager. The number of PDOs is given in sub-index 0 of the sync manager PDO assignment table. In this ...

https://www.fa.omron.co.jp/data_pdf/mnu/e429-e1-12_e3nw-ect.pdf

マニュアル
PDF[H192-E1-02] EJ1N-HFUC-ECT EJ1 EtherCAT® Slave Uni...
... hex 6UUU hex UU hex 8 03 hex 16 6YYY hex YY hex PDO-Length : 32 Bit PDO_1 Application object TT hex 3 Object D Object A 6UUU hex UU hex Object B 6VVV hex VV hex Object C 6YYY hex YY hex Object D 6ZZZ hex Object E ZZ hex Object B EJ1 EtherCAT Slave Unit User’s Manual (H192) 3-2-4 Process Data Objects (PDOs) 6TTT hex Object A 3-2 EtherCAT Communications Overview The PDO mapping scheme in EtherCAT is described below. 3-9 3 Part Names and EtherCAT Communications Overview 3-2-5...

https://www.fa.omron.co.jp/data_pdf/mnu/h192-e1-02_ej1n-hfuc-ect.pdf

マニュアル
PDF[I574-E1-05] 3G3AX-MX2-ECT/RX-ECT Inverter EtherCA...
...1ZZZ hex 03 hex YYYY hex YY hex 16 PDO length: 32 bits Application objects PDO_1 Object A Object B 3-4 6TTT hex 6UUU hex 6VVV hex 6YYY hex 6ZZZ hex TT hex UU hex VV hex YY hex ZZ hex Object D Object A Object B Object C Object D Object E EtherCAT Communication Unit USER’S MANUAL (I574-E1) 3 Common Slave Specifications 3-3-3 Sync Manager PDO Assignment Settings The number of PDOs is given in sub-index 00 hex of the Sync Manager PDO assignment table. In this table, index 1C12 hex is ...

https://www.fa.omron.co.jp/data_pdf/mnu/i574-e1-05_3g3ax-mx2-ect_rx-ect.pdf

マニュアル
PDF[I663-E1-02] 3G3AX-RX2-ECT Inverter EtherCAT® Comm...
... hex YY hex 8 8 16 PDO length: 32 bits Application objects PDO_1 Object A Object B 3-4 6TTT hex 6UUU hex 6VVV hex 6YYY hex 6ZZZ hex TT hex UU hex VV hex YY hex ZZ hex Object D Object A Object B Object C Object D Object E EtherCAT Communication Unit USER’S MANUAL (I663) 3 EtherCAT Communications 3-3-3 Sync Manager PDO Assignment Settings The number of PDOs is given in sub-index 00 hex of the Sync Manager PDO assignment table. In this table, index 1C12 hex is for RxPDOs and 1C13 ...

https://www.fa.omron.co.jp/data_pdf/mnu/i663-e1-02_3g3ax-rx2-ect.pdf

マニュアル
PDF[I664-E-02] TM Collaborative Robot TMscript Langua...
... byte, int, float, double, bool, string) * The data type of array1 and array2 must be identical. Return bool Two arrays are identical or not? true two arrays are identical false two arrays are not identical Syntax 2 bool Array_Equals( ?[],...

https://www.fa.omron.co.jp/data_pdf/mnu/i664-e-02_tmscript_language.pdf

マニュアル
PDF[I848-E-04] Expression Editor and Listen Node Refe...
..., int, float, double, bool, string) * The data type of array1 and array2 must be identical. Return bool Two arrays are identical or not? true false two arrays are identical two arrays are not identical Syntax 2 bool Array_Equals( ?[],...

https://www.fa.omron.co.jp/data_pdf/mnu/i848-e-04_expression_editor.pdf

マニュアル
PDF[O010-E1-01] FQM1-CM001/MMP21/MMA21 Flexible Motio...
...: XM2S-0911-E RS-232C port Plug: XM2A-0901 UL2464 AWG28 × 5P IFS-RVV-SB (UL product) AWG 28 × 5P IFVV-SB (non-UL product) Hitachi Cable, Ltd.: UL2464-SB (MA) 5P × 28AWG (7/0.127) (UL product) CO-MA-VV-SB 5P × 28AWG (7/0.127) (non-UL product) Fujikura Ltd.: Use the special cables provided from OMRON for all connections whenever possible. If cables are produced in-house, be sure they are wired correctly. External devices and the Coordinator Module may be damaged if general-purpose (e.g., computer to modem) cables are ...

https://www.fa.omron.co.jp/data_pdf/mnu/o010-e1-01_fqm1-cm001_mmp21_mma21.pdf

マニュアル
PDF[O012-E1-03] FQM1-CM002/MMP22/MMA22 Flexible Motio...
...: XM2S-0911-E RS-232C port Plug: XM2A-0901 UL2464 AWG28 × 5P IFS-RVV-SB (UL product) AWG 28 × 5P IFVV-SB (non-UL product) Hitachi Cable, Ltd.: UL2464-SB (MA) 5P × 28AWG (7/0.127) (UL product) CO-MA-VV-SB 5P × 28AWG (7/0.127) (non-UL product) Note 102 Use the special cables provided from OMRON for all connections whenever possible. If cables are produced in-house, be sure they are wired correctly. External devices and the Coordinator Module may be damaged if general-purpose (e.g., computer to modem) cables are ...

https://www.fa.omron.co.jp/data_pdf/mnu/o012-e1-03_fqm1-com_mm.pdf

マニュアル
PDF[P545-E1-01] G9SP Safety Controller NJ-series Gene...
...Safety input terminal 19 Safety input terminal 16 Safety input terminal 18 Not used Safety input terminal 01 Safety input terminal 03 Safety input terminal 00 Safety input terminal 02 : #16#uu #16#vv Data[64] to [69] Data[70] to [71] Data[72] Fixed (Response length (HL)) Fixed (Response length (LH)) Fixed (Response length (LL)) Fixed (End code (H)) Fixed (End code (L)) Fixed Bits 00 to 07 Bits 08 to 15 Bits 16 to 23 Bits 24 to 31 Bits 00 to 07 Bits 08 to 15 Bits 16 to 19 Not used Bits 00 to 07 Bits ...

https://www.fa.omron.co.jp/data_pdf/mnu/p545-e1-01_g9sp.pdf