全 412 件が検索されました。(401 - 412件を表示)
- マニュアル
...2 6 1 Pin 1 Signal Name FG Protective frame ground 2 SD For RS-232C 3 RD 4 NC Not connected 5 RDB(+) For RS-422 6 RDA(-) 7 SDB(+) 8 SDA(-) 9 GND Signal ground The following plug and hood are recommended and are available from OMRON. Model 4-2-3 Model No. Plug XM2A-0901 Hood XM2S-0911 Wiring The maximum cable length is 15 m for RS-232C or RS-422 RS-232C Wiring F160 External device Signal Pin SD 2 SD RD 3 RD GND 9 GND Pin Use only shielded cable. 36 Signal RS/...
- マニュアル
...resistance) SW1-3: OFF SW1-4: OFF SW1-5: OFF SW1-6: OFF Note Signal Signal 1 2 3 4 5 6 7 8 GRD SG SDB SDA RDB RDA CSB CSA NC 1 SD 2 RD 3 RS 4 CS 5 5V 6 DR 7 ER 8 SG 9 RS-232 RS-422 DIP SW SW1-1: ON SW1-2: OFF Pin *1 No. *2 Signal Signal 1 2 3 4 5 6 7 8 9 Signal GR SD RD RS CS 5V SG D-sub 9-pin (Cable connector: Male) ID Controller NT-AL001 Pin No. ID Controller...
- マニュアル
..., hold the ID Controller and pull the connector off. Lock screws RFID System Operation Manual 29 Section 2 Installation and Wiring RS-422/RS-485 Port Pin Arrangement Section 2 Wiring Pin No. Name 1 RDA...
- マニュアル
...DC model: 24 VDC or 24 VAC (50 to 60 Hz) 44 Pin Name 1 2 3 4 5 6 PWR NC SG PWR SD RD Name Pin RS-485 SG RDA(-) SDA(-) NC RDB(+) SDB(+) S8M K3SC-10 K3SC-10 Name Pin 7 8 9 10 11 12 Pin Name 7 (See note.) 8 9 10 (See 11 note.) 12 SG ...
- マニュアル
...9 Signal name FG SD RD RS CS NC NC NC GND Shell FG Note 1: Male connector ZFX-XPT2B/XPT5B/XPT15B Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDA(-) SDB(+) NC NC NC ...
- マニュアル
...8 9 Signal name FG SD RD RS CS NC NC NC GND Shell FG 7 Note 1: Male connector Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDA(-) SDB(+) NC NC NC ...
- マニュアル
...3 4 5 6 7* Terminal name RD (RXD) SD (TXD) SG (GND) 8 9 10 11 12 13 14 15 RDB (+) RDA () SDB (+) SDA () 9 15 Function (Not used) Enters data from the external device. Outputs data from the controller. (Not used) (Not used) (Not used) A signal ground. Connects the SG (GND) terminal on the external device. (Not used) Enters data from the external device. Enters data from the external device. Outputs data from the controller. Outputs data from the controller. (Not used) (Not used) (Not used) * Even ...
- マニュアル
...2 3 4 5 6 7 RD (RXD) SD (TXD) SG (GND) 8 9 10 11 12 13 14 15 RDB () RDA () SDB ( SDA ( (Not used) Enters data from the external device. Outputs data from the controller. (Not used) (Not used) (Not used) A signal ground. Connects the SG (GND) terminal on the external device. (Not used) Enters data from the external device. Enters data from the external device. Outputs data from the controller. Outputs data from the controller. (Not used) (Not used) (Not used) Fiber ...
- マニュアル
...3 4 5 6 7* Terminal name RD (RXD) SD (TXD) SG (GND) 8 9 10 11 12 13 14 15 RDB (+) RDA () SDB (+) SDA () 9 15 Function (Not used) Enters data from the external device. Outputs data from the controller. (Not used) (Not used) (Not used) A signal ground. Connects the SG (GND) terminal on the external device. (Not used) Enters data from the external device. Enters data from the external device. Outputs data from the controller. Outputs data from the controller. (Not used) (Not used) (Not used) * Even ...
- マニュアル
...2 3 4 5 6 7 RD (RXD) SD (TXD) SG (GND) 8 9 10 11 12 13 14 15 RDB () RDA () SDB ( SDA ( (Not used) Enters data from the external device. Outputs data from the controller. (Not used) (Not used) (Not used) A signal ground. Connects the SG (GND) terminal on the external device. (Not used) Enters data from the external device. Enters data from the external device. Outputs data from the controller. Outputs data from the controller. (Not used) (Not used) (Not used) Fiber ...
- マニュアル
...D-Sub9 Male type connector is used in Sensor Controller. Pin No. 9 8 7 6 1 2 3 4 5 6 7 8 9 Signal name SDB(+) SD/SDA(-) RD/RDA(-) RDB(+) NC NC NC NC GND Function For RS-422 For RS-232C/RS-422 For RS-232C/RS-422 For RS-422 Not connected Not connected Not connected Not connected Signal ground 6-5 Serial Interface 5 4 3 2 1 6 • Bundle each cable with SG (signal ground) as a twisted pair cable. Connect the bundled SG cables with the connector on the Sensor Controller and ...
- マニュアル
...ケーブル被覆部:耐熱塩化ビニル (PVC) NC 3 3 NC 最小曲げ半径 NC 4 NC 付属品 RDB(+) 4 5 6 RDA(-) RDA(-) SDB(+) 7 7 NC SDA(-) 8 9 10 シェル 8 9 RDB(+) SG(GND) シェル FG ご使用に際してのご承諾事項 L (注1) 100±10 32.2 (20±5) 41 ■清掃についてシンナー、ベンゼン、 アセトン、灯油...