ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索

検索結果を絞り込む


全文検索:全 416 件が検索されました。(361 - 380件を表示)
マニュアル
PDF[Z103-E1-05] E5[]J Temperature Controller Operatio...
...(20 mA max.) 250 VAC 3A 27 26 25 24 23 22 250 VAC 3A 21 CT Communications terminal RS-232C RDB 20 29 B(+) RD 19 28 RDA 19 28 A(–) 18 27 SG 18 27 SG 18 27 SG 17 26 SD 17 26 SDA 17 26 A(–) SG 16 25 SDB 16 25 B(+) 20 29 19 19 28 17 16 25 16 RS-485 20 29 20 18 RS-422 15 14 A 13 12 11 – B + B Use the E54-CT1 with a hole diameter of 5.8 mm or E54-CT3 with a ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z103-e1-05_e5_j.pdf

マニュアル
PDF[Z144-E1-04] F160 Vision Sensor Setup Manual
...2 6 1 Pin 1 Signal Name FG Protective frame ground For RS-232C 2 SD 3 RD 4 NC Not connected 5 RDB(+) For RS-422 6 RDA(-) 7 SDB(+) 8 SDA(-) 9 GND Signal ground The following plug and hood are recommended and are available from OMRON. Model 4-2-3 Model No. Plug XM2A-0901 Hood XM2S-0911 Wiring The maximum cable length is 15 m for RS-232C or RS-422 RS-232C Wiring F160 External device Signal Pin SD 2 SD RD 3 RD GND 9 GND Pin Use only shielded cable. 36 Signal RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z144-e1-04_f160.pdf

マニュアル
PDFz152-e1-02_e3x-drt21_srt21_cif11.pdf
.../F message communications Sends CompoWay/F messages from the master. Section 4-4 Wiring RS-422 Communication Units 4-4-1 Wiring RS-422 Communication Units RS-422 Communications Wiring The RS-422 Connector pin arrangement is as follows: RDB ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z152-e1-02_e3x-drt21_srt21_cif11.pdf

マニュアル
PDF[Z169-E1-04] V530-R160E/R160EP 2D Code Reader User...
...Function 4 1 FG Protective frame ground 3 2 SD RS-232C 2 3 RD RS-232C 1 4 NC Not connected 5 RDB(RD+) RS-422 6 RDA( RD- ) RS-422 7 SDB(SD+) RS-422 8 SDA( SD- ) RS-422 9 GND Connecting through the Serial Interface Pin SECTION 3 6 5 Signal ground  RS-422 Block Diagram SDB(SD+) SDA(SD-) RDB(RD+) ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z169-e1-04_v530-r160e_-r160ep.pdf

マニュアル
PDF[Z170-E1-02E] F160-2 Vision Sensor Setup Manual
...2 6 1 Pin 1 Signal Name FG Protective frame ground 2 SD For RS-232C 3 RD 4 NC Not connected 5 RDB(+) For RS-422 6 RDA(-) 7 SDB(+) 8 SDA(-) 9 GND Signal ground The following plug and hood are recommended and are available from OMRON. Model 4-2-3 Model No. Plug XM2A-0901 Hood XM2S-0911 Wiring The maximum cable length is 15 m for RS-232C or RS-422 RS-232C Wiring F160 External device Signal Pin SD 2 SD RD 3 RD GND 9 GND Pin Use only shielded cable. 36 Signal RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z170-e1-02e_f160-2.pdf

マニュアル
PDFz194-e1-03_v600-idsc02_04.pdf
...resistance) SW1-3: OFF SW1-4: OFF SW1-5: OFF SW1-6: OFF Note Signal Signal 1 2 3 4 5 6 7 8 GRD SG SDB SDA RDB RDA CSB CSA NC 1 SD 2 RD 3 RS 4 CS 5 5V 6 DR 7 ER 8 SG 9 RS-232 RS-422 DIP SW SW1-1: ON SW1-2: OFF Pin *1 No. *2 Signal Signal 1 2 3 4 5 6 7 8 9 Signal GR SD RD RS CS 5V SG D-sub 9-pin (Cable connector: Male) ID Controller NT-AL001 Pin No. ID Controller...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z194-e1-03_v600-idsc02_04.pdf

マニュアル
PDF[Z251-E1-04] ZFX-C10 Smart Sensor (Vision Sensor w...
...9 Signal name FG SD RD RS CS NC NC NC GND Shell FG Note 1: Male connector ZFX-XPT2B/XPT5B/XPT15B Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDA(-) SDB(+) NC NC NC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z251-e1-04_zfx-c10.pdf

マニュアル
PDF[Z264-E1-09] ZFX-C Smart Sensor (Vision Sensor wit...
...8 9 Signal name FG SD RD RS CS NC NC NC GND Shell FG 7 Note 1: Male connector Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDA(-) SDB(+) NC NC NC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z264-e1-09_zfx-c.pdf

マニュアル
PDF[Z358-E1-03] MX-Z2000G Series Fiber Laser Marker S...
...3 4 5 6 7* Terminal name  RD (RXD) SD (TXD)    SG (GND) 8 9 10 11 12 13 14 15  RDB (+) RDA () SDB (+) SDA ()    9 15 Function (Not used) Enters data from the external device. Outputs data from the controller. (Not used) (Not used) (Not used) A signal ground. Connects the SG (GND) terminal on the external device. (Not used) Enters data from the external device. Enters data from the external device. Outputs data from the controller. Outputs data from the controller. (Not used) (Not used) (Not used) * Even ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z358-e1-03_mx-z2000g.pdf

マニュアル
PDF[Z359-E1-03] MX-Z2000G Series Fiber Laser Marker ...
...2 3 4 5 6 7  RD (RXD) SD (TXD)    SG (GND) 8 9 10 11 12 13 14 15  RDB () RDA () SDB ( SDA (    (Not used) Enters data from the external device. Outputs data from the controller. (Not used) (Not used) (Not used) A signal ground. Connects the SG (GND) terminal on the external device. (Not used) Enters data from the external device. Enters data from the external device. Outputs data from the controller. Outputs data from the controller. (Not used) (Not used) (Not used) Fiber ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z359-e1-03_mx-z2000g.pdf

マニュアル
PDF[Z376-E1-06] MX-Z2000H series Fiber Laser Marker S...
...3 4 5 6 7* Terminal name  RD (RXD) SD (TXD)    SG (GND) 8 9 10 11 12 13 14 15  RDB (+) RDA () SDB (+) SDA ()    9 15 Function (Not used) Enters data from the external device. Outputs data from the controller. (Not used) (Not used) (Not used) A signal ground. Connects the SG (GND) terminal on the external device. (Not used) Enters data from the external device. Enters data from the external device. Outputs data from the controller. Outputs data from the controller. (Not used) (Not used) (Not used) * Even ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z376-e1-06_mx-z2000h.pdf

マニュアル
PDF[Z377-E1-06] MX-Z2000H series Fiber Laser Marker U...
...2 3 4 5 6 7  RD (RXD) SD (TXD)    SG (GND) 8 9 10 11 12 13 14 15  RDB () RDA () SDB ( SDA (    (Not used) Enters data from the external device. Outputs data from the controller. (Not used) (Not used) (Not used) A signal ground. Connects the SG (GND) terminal on the external device. (Not used) Enters data from the external device. Enters data from the external device. Outputs data from the controller. Outputs data from the controller. (Not used) (Not used) (Not used) Fiber ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z377-e1-06_mx-z2000h.pdf

マニュアル
PDF[Z423-E1-02] FZ5 Series Vision System Hardware Set...
...D-Sub9 Male type connector is used in Sensor Controller. Pin No. 9 8 7 6 1 2 3 4 5 6 7 8 9 Signal name SDB(+) SD/SDA(-) RD/RDA(-) RDB(+) NC NC NC NC GND Function For RS-422 For RS-232C/RS-422 For RS-232C/RS-422 For RS-422 Not connected Not connected Not connected Not connected Signal ground 6-5 Serial Interface 5 4 3 2 1 6 • Bundle each cable with SG (signal ground) as a twisted pair cable. Connect the bundled SG cables with the connector on the Sensor Controller and ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z423-e1-02_fz5.pdf

マニュアル
PDF[1284053-0D] ZFX-XPT□B プログラマブルコントローラ/プログラマブルターミナル接...
...ケーブル被覆部:耐熱塩化ビニル (PVC) NC 3 3 NC 最小曲げ半径 NC 4 NC 付属品 RDB(+) 4 5 6 RDA(-) RDA(-) SDB(+) 7 7 NC SDA(-) 8 9 10 シェル 8 9 RDB(+) SG(GND) シェル FG ご使用に際してのご承諾事項 L (注1) 100±10 32.2 (20±5) 41 ■清掃についてシンナー、ベンゼン、 アセトン、灯油...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/zfx-xpt_b_inst-1284053-0d.pdf

推奨代替品ガイド
PDFデジタル指示温度調節器 形E5EJシリーズ 生産終了のお知らせ
...7 − 100∼ 240VAC 50/60Hz 8 制御出力 7 6 5 4 警報出力2 3 ** 警報出力1 2 1 29 B(−) 28 RDA 28 A(+) SG 27 27 SG SD 26 SDA 26 A(+) 3 25 SG 25 25 B(−) 4 SDB 28 27 26 25 24 23 22 21 19 18 イベント1* 5 16 6 ALM3/ 制御出力2 7 15 11 SD 11 12 RD 12 13 SG 13 1 11 8 13 13 − 熱電対測温体の場合 + 12...

https://www.fa.omron.co.jp/data_pdf/closed/1999202.pdf

推奨代替品ガイド
PDFRFIDシステム 形V630シリーズ 生産終了のお知らせ
...SDA − ○ 9 送信データB SD− − ○ 送信データB (SD+) SDB − ○ 5 受信データA RD+ ○ − 受信データA (RD−) RDA ○ − 6 受信データB RD− ○ − 受信データB (RD+) RDB ○ − 1 ピン配列(はんだ付け側より見た図です) 5 1 9 ・1対N接続時のR/Wヘッド間の接続 R/Wヘッド端子名称 SD+ SD− RD+ RD− SG...

https://www.fa.omron.co.jp/data_pdf/closed/2001115.pdf

推奨代替品ガイド
PDFファジィ温度調節器 基本タイプ 形E5AF 生産終了のお知らせ
...温体の場合 15 ( 14 の短絡片は、 付けたままにして + おきます) 4∼20mA伝送出力 通信端子部 RS-422 RS-485 RDB RDA SG SDA SDB ヒータ断線警報付の場合 通信用コネクタ (通信機能付の場合、 図はRS232C、BCDの場合です) B(+) A(−) SG A(−) B(+) 通信用端子台(図はRS-422、 RS-485の場合で...

https://www.fa.omron.co.jp/data_pdf/closed/2001116.pdf

推奨代替品ガイド
PDFデジタル指示温度調節器 基本タイプ 形E5AX 生産終了のお知らせ
...温体の場合 15 ( 14 の短絡片は、 付けたままにして + おきます) 4∼20mA伝送出力 通信端子部 RS-422 RS-485 RDB RDA SG SDA SDB ヒータ断線警報付の場合 通信用コネクタ (通信機能付の場合、 図はRS232C、BCDの場合です) B(+) A(−) SG A(−) B(+) 通信用端子台(図はRS-422、 RS-485の場合で...

https://www.fa.omron.co.jp/data_pdf/closed/2001117.pdf

推奨代替品ガイド
PDFデジタル指示温度調節器 電流電圧入力タイプ 形E5AX-LA/-MA 生産終了のお知らせ
...1∼5V、0∼5V、 0∼1Vの場合 + − 4∼20mA、 0∼20mAの場合 + コネクタ 4∼20mA伝送出力 通信端子部 RS-422 RS-485 RDB RDA SG SDA SDB 形E5AX-MAの場合 14 13 12 11 − 0∼100mVの場合 + − B(+) A(−) SG A(−) B(+) 0∼10mV、 −10∼10mVの場合 + 通信用コネクタ (通信機能付の場合、 図はRS232C、BCDの場合です) 通信用端子台(図はRS-...

https://www.fa.omron.co.jp/data_pdf/closed/2001118.pdf

推奨代替品ガイド
PDFデジタル指示温度調節器 コントロールバルブ制御タイプ 形E5AX-PRR 生産終了のお知らせ
...まにして + おきます) 14 4 13 3 12 2 11 1 4∼20mA伝送出力 B 15 通信端子部 RS-422 RS-485 RDB RDA SG SDA SDB 通信用コネクタ (通信機能付の場合、 図はRS232C、BCDの場合です) B(+) A(−) SG A(−) B(+) 通信用端子台(図はRS-422、 RS-485の場合です) 推奨代替商品形E5AK(コントロールバル...

https://www.fa.omron.co.jp/data_pdf/closed/2001119.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。