全 399 件が検索されました。(381 - 399件を表示)
- マニュアル
... outputs: 18 19 HH H 20 21 22 PASS 23 L LL COM 24 25 26 Output NPN Tr. (50 mA max. at 12 to 24 VDC) LL OFF RDA RS-485 + – K31-S6: RS-422 + Transistor Terminator Outputs (50 mA max. at 12 to 24 VDC) ON SDA K31-S5: RS-485 + Transistor Terminator ON 4 8 RUN COMMON REQUEST MAX. REQ. MIN. REQ. HOLD RESET POLARITY HH H PASS L LL COMMON 104 DATA OVERFLOW DATA VALID K31-B4: BCD + Transistor (NPN Open Collector) 1 2 4 8 1 2 4 8 1 2 4 8 1 ...
- マニュアル
...(20 mA max.) 250 VAC 3A 27 26 25 24 23 22 250 VAC 3A 21 CT Communications terminal RS-232C RDB 20 29 B(+) RD 19 28 RDA 19 28 A(–) 18 27 SG 18 27 SG 18 27 SG 17 26 SD 17 26 SDA 17 26 A(–) SG 16 25 SDB 16 25 B(+) 20 29 19 19 28 17 16 25 16 RS-485 20 29 20 18 RS-422 15 14 A 13 12 11 – B + B Use the E54-CT1 with a hole diameter of 5.8 mm or E54-CT3 with a ...
- マニュアル
...NT-AL001 Signal NT-AL001 Signal Pin No. Pin No. SG (GND) 2 2 SG (GND) SDB 3 3 SDB SDA 4 4 SDA RDB 5 5 RDB RDA 6 6 RDA Connection 3 The wiring required between the NT-AL001 on the host side and the NT-AL001 on the V530-R150 side is shown below. NT-AL001 on host side Signal 66 NT-AL001 on V530-R150 side Signal Pin No. Pin No. SG (GND) 2 2 SG (GND) SDB 3 3 SDB SDA 4 4 SDA RDB 5 5 RDB ...
- マニュアル
...2 6 1 Pin 1 Signal Name FG Protective frame ground For RS-232C 2 SD 3 RD 4 NC Not connected 5 RDB(+) For RS-422 6 RDA(-) 7 SDB(+) 8 SDA(-) 9 GND Signal ground The following plug and hood are recommended and are available from OMRON. Model 4-2-3 Model No. Plug XM2A-0901 Hood XM2S-0911 Wiring The maximum cable length is 15 m for RS-232C or RS-422 RS-232C Wiring F160 External device Signal Pin SD 2 SD RD 3 RD GND 9 GND Pin Use only shielded cable. 36 Signal RS/...
- マニュアル
.../F message communications Sends CompoWay/F messages from the master. Section 4-4 Wiring RS-422 Communication Units 4-4-1 Wiring RS-422 Communication Units RS-422 Communications Wiring The RS-422 Connector pin arrangement is as follows: RDB ...
- マニュアル
...NT-AL001 Signal NT-AL001 Signal Pin No. Pin No. SG (GND) SDB 2 3 2 3 SG (GND) SDB SDA 4 4 SDA RDB 5 5 RDB RDA 6 6 RDA Connection 3 The wiring required between the NT-AL001 on the host side and the NT-AL001 on the V530-R150 side is shown below. NT-AL001 on host side Signal 96 NT-AL001 on V530-R150 side Signal Pin No. Pin No. SG (GND) 2 2 SG (GND) SDB 3 3 SDB SDA 4 4 SDA RDB 5 5 RDB ...
- マニュアル
...Function 4 1 FG Protective frame ground 3 2 SD RS-232C 2 3 RD RS-232C 1 4 NC Not connected 5 RDB(RD+) RS-422 6 RDA( RD- ) RS-422 7 SDB(SD+) RS-422 8 SDA( SD- ) RS-422 9 GND Connecting through the Serial Interface Pin SECTION 3 6 5 Signal ground RS-422 Block Diagram SDB(SD+) SDA(SD-) RDB(RD+) ...
- マニュアル
...2 6 1 Pin 1 Signal Name FG Protective frame ground 2 SD For RS-232C 3 RD 4 NC Not connected 5 RDB(+) For RS-422 6 RDA(-) 7 SDB(+) 8 SDA(-) 9 GND Signal ground The following plug and hood are recommended and are available from OMRON. Model 4-2-3 Model No. Plug XM2A-0901 Hood XM2S-0911 Wiring The maximum cable length is 15 m for RS-232C or RS-422 RS-232C Wiring F160 External device Signal Pin SD 2 SD RD 3 RD GND 9 GND Pin Use only shielded cable. 36 Signal RS/...
- マニュアル
...resistance) SW1-3: OFF SW1-4: OFF SW1-5: OFF SW1-6: OFF Note Signal Signal 1 2 3 4 5 6 7 8 GRD SG SDB SDA RDB RDA CSB CSA NC 1 SD 2 RD 3 RS 4 CS 5 5V 6 DR 7 ER 8 SG 9 RS-232 RS-422 DIP SW SW1-1: ON SW1-2: OFF Pin *1 No. *2 Signal Signal 1 2 3 4 5 6 7 8 9 Signal GR SD RD RS CS 5V SG D-sub 9-pin (Cable connector: Male) ID Controller NT-AL001 Pin No. ID Controller...
- マニュアル
..., hold the ID Controller and pull the connector off. Lock screws RFID System Operation Manual 29 Section 2 Installation and Wiring RS-422/RS-485 Port Pin Arrangement Section 2 Wiring Pin No. Name 1 RDA...
- マニュアル
...DC model: 24 VDC or 24 VAC (50 to 60 Hz) 44 Pin Name 1 2 3 4 5 6 PWR NC SG PWR SD RD Name Pin RS-485 SG RDA(-) SDA(-) NC RDB(+) SDB(+) S8M K3SC-10 K3SC-10 Name Pin 7 8 9 10 11 12 Pin Name 7 (See note.) 8 9 10 (See 11 note.) 12 SG ...
- マニュアル
...9 Signal name FG SD RD RS CS NC NC NC GND Shell FG Note 1: Male connector ZFX-XPT2B/XPT5B/XPT15B Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDA(-) SDB(+) NC NC NC ...
- マニュアル
...8 9 Signal name FG SD RD RS CS NC NC NC GND Shell FG 7 Note 1: Male connector Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDA(-) SDB(+) NC NC NC ...
- マニュアル
...3 4 5 6 7* Terminal name RD (RXD) SD (TXD) SG (GND) 8 9 10 11 12 13 14 15 RDB (+) RDA () SDB (+) SDA () 9 15 Function (Not used) Enters data from the external device. Outputs data from the controller. (Not used) (Not used) (Not used) A signal ground. Connects the SG (GND) terminal on the external device. (Not used) Enters data from the external device. Enters data from the external device. Outputs data from the controller. Outputs data from the controller. (Not used) (Not used) (Not used) * Even ...
- マニュアル
...2 3 4 5 6 7 RD (RXD) SD (TXD) SG (GND) 8 9 10 11 12 13 14 15 RDB () RDA () SDB ( SDA ( (Not used) Enters data from the external device. Outputs data from the controller. (Not used) (Not used) (Not used) A signal ground. Connects the SG (GND) terminal on the external device. (Not used) Enters data from the external device. Enters data from the external device. Outputs data from the controller. Outputs data from the controller. (Not used) (Not used) (Not used) Fiber ...
- マニュアル
...3 4 5 6 7* Terminal name RD (RXD) SD (TXD) SG (GND) 8 9 10 11 12 13 14 15 RDB (+) RDA () SDB (+) SDA () 9 15 Function (Not used) Enters data from the external device. Outputs data from the controller. (Not used) (Not used) (Not used) A signal ground. Connects the SG (GND) terminal on the external device. (Not used) Enters data from the external device. Enters data from the external device. Outputs data from the controller. Outputs data from the controller. (Not used) (Not used) (Not used) * Even ...
- マニュアル
...2 3 4 5 6 7 RD (RXD) SD (TXD) SG (GND) 8 9 10 11 12 13 14 15 RDB () RDA () SDB ( SDA ( (Not used) Enters data from the external device. Outputs data from the controller. (Not used) (Not used) (Not used) A signal ground. Connects the SG (GND) terminal on the external device. (Not used) Enters data from the external device. Enters data from the external device. Outputs data from the controller. Outputs data from the controller. (Not used) (Not used) (Not used) Fiber ...
- マニュアル
...D-Sub9 Male type connector is used in Sensor Controller. Pin No. 9 8 7 6 1 2 3 4 5 6 7 8 9 Signal name SDB(+) SD/SDA(-) RD/RDA(-) RDB(+) NC NC NC NC GND Function For RS-422 For RS-232C/RS-422 For RS-232C/RS-422 For RS-422 Not connected Not connected Not connected Not connected Signal ground 6-5 Serial Interface 5 4 3 2 1 6 • Bundle each cable with SG (signal ground) as a twisted pair cable. Connect the bundled SG cables with the connector on the Sensor Controller and ...
- マニュアル
...ケーブル被覆部:耐熱塩化ビニル (PVC) NC 3 3 NC 最小曲げ半径 NC 4 NC 付属品 RDB(+) 4 5 6 RDA(-) RDA(-) SDB(+) 7 7 NC SDA(-) 8 9 10 シェル 8 9 RDB(+) SG(GND) シェル FG ご使用に際してのご承諾事項 L (注1) 100±10 32.2 (20±5) 41 ■清掃についてシンナー、ベンゼン、 アセトン、灯油...