ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索

検索結果を絞り込む


全文検索:全 558 件が検索されました。(381 - 400件を表示)
マニュアル
PDF[W207-E1-02] CV500-BSC11/BSC21/BSC31/BSC41/BSC51/B...
...'0η} Calculatesthearctangentofthe,θ)¢)「θss'oη・ 32 CDBL .CDBL(θXρreSS'0η) Convertsθxρ佗ssた)nintoadouble-precisionrealnumber 33 CHRS CHRS(θκρrθSSわη} Convertsθxρ佗ssわηintocharacters. 34 CINT ,CINT(θXρrθSS氾η) Roundsanyfractionalpartofθ)ψr●ssわη 35 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w207-e1-02_cv500-bsc.pdf

マニュアル
PDF[W217-E1-02] C200H-CPU21-E/CPU23-E/CPU31-E Program...
... ≤ 0900 (0°≤Θ≤ 90°). Description When the execution condition is OFF, VCAL(69) is not executed. When the execution condition is ON, the operation of VCAL(69) depends on the control word C. If C is #0000 or #0001, VCAL(69) computes sin(x) or ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w217-02_c200h-cpu21-e_23-e_31-e.pdf

マニュアル
PDFw222-03_cvm1-prs21-ev1.pdf
...-POINT SUBTRACT 456 *F(j)* FLOATING-POINT MULTIPLY 457 /F(j)* FLOATING-POINT DIVIDE 458 RAD(j)* DEGREES-TO-RADIANS 459 DEG(j)* RADIANS-TO-DEGREES 460 SIN(j)* SINE 461 COS(j)* COSINE 462 TAN(j)* TANGENT 463 ASIN(j)* SINE-TO-ANGLE 464 ACOS(j)* COSINE-TO-ANGLE 465 ATAN(j)* TANGENT-TO-ANGLE 466 SQRT(j)* SQUARE ROOT 467 EXP(j)* EXPONENT 468 LOG(j)* LOGARITHM Note Instructions with one asterisk (*) are supported by the CVM1D and version-2 CVM1 CPU Units only. 152 Instructions with two asterisks (**) are supported by the CV500, CV1000, and CV2000 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w222-03_cvm1-prs21-ev1.pdf

マニュアル
PDF[W235-E1-04] C200HS Programmable Controllers Opera...
... to 0900 (0°≤ q ≤ 90°). Description When the execution condition is OFF, APR(69) is not executed. When the execution condition is ON, the operation of APR(69) depends on the control word C. If C is #0000 or #0001, APR(69) computes sin(q) or ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w235-e1-04_c200hs.pdf

マニュアル
PDF[W236-E1-07] C200HS Programmable Controllers Insta...
... output Screw (3.5 mm head with self-raising pressure plate) RUN Output These terminals are short-circuited during PC operation. Use them to receive PC RUN signals, for purposes such as emergency stop circuits. Maximum switching capacity: 250 VAC, 2 A (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w236-e1-07_c200hs.pdf

マニュアル
PDF[W350-E1-02] CVM1D-DPL Duplex System Programmable...
...or MONITOR mode. These terminals can thus be wired to provide an external signal indicating the operating status of the PC, such as is used in the emergency stop circuit shown in 3-6-1 Emergency Stop Circuit. Maximum switching capacity: 250 VAC/2 A (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w350-02_cvm1d-dpl.pdf

マニュアル
PDF[W351-E1-03] CVM1D-DPL Duplex System Programmable ...
.... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21-12 COSINE: COS(461) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21-13 TANGENT: TAN(462) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 219 222 224 225 226 227 230 232 234 236 237 238 238 238 239 241 242 243 244 245 246 249 249 250 252 253 254 255 256 257 259 259 261 263 268 272 274 276 278 280 283 284 285 285 286 287 288 289 290 291 292 293 294 97 5-22 5-23 5-24 5-25 5-26 5-27 5-28 98 5-21-14 SINE TO ANGLE: ASIN(463) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21-15 COSINE TO ANGLE: ACOS(464) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w351-e1-03_cvm1d-dpl.pdf

マニュアル
PDFw378-e1-02_cs1w-hio_hcp_hca_v1.pdf
... is either in BIN 16 bit or BIN 32 bit. 180 Section 7-14 Improved Instructions In 32 Bit [D]: Calculation result (rightmost 4 digits) [D+1]: Calculation result (leftmost 4 digits) In 16 Bit [D]: Calculation result (4 digits) SIN/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w378-e1-02_cs1w-hio_hcp_hca_v1.pdf

マニュアル
PDFw380-e1-10_cs1w_cj1w-drm.pdf
... DM Area words. Specifications Section 1-3 Item Supported connections (communications) Remote I/O Slave allocation method master communications Fixed allocations User-set allocations Specifications • Remote I/O communications (master and slave): Master/slave connection (poll, bit-strobe, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w380-e1-10_cs1w_cj1w-drm.pdf

マニュアル
PDF[W381-E1-03] 3G8F7-DRM21-E DeviceNet™ PCI Board Op...
... nodes capable of simultaneous communications as explicit servers Data length for explicit messages Response monitoring time for explicit messages (for clients) Retries for explicit messages Note Minimum System Requirements Specifications • Bit Strobe • Polling • Cyclic • Change of State (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w381-e1-03_3g8f7-drm21-e.pdf

マニュアル
PDF[W419-E1-04] CS1W-MCH71 Motion Control Unit Operat...
...2nd Term 3rd Term AND (Logical AND) & #MW- = #MW- 1st Term & #MW-; 2nd Term 3rd Term Functions NOT (Reverse) ! Absolute value ABS Sine SIN Cosine Tangent ARC Sine COS TAN ASIN ARC Cosine ACOS ARC Tangent ATAN Square root SQR Normal logarithm EXP Natural logarithm LOG Decimal point Variable R/W B W L F @ --- No No Write Yes Yes Yes No No LONGMINLONGMAX Yes Integer Read Yes Yes Yes No Yes LONGMINLONGMAX Yes Integer Read Yes Yes Yes No Yes --- No No Write No Yes Yes No No LONGMINLONGMAX Yes Integer Read No Yes Yes No Yes LONGMINLONGMAX Yes...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w419-e1-04_cs1w-mch71.pdf

マニュアル
PDF[W452-E1-08] NSJ5, NSJ8, NSJ10, NSJ12, NSJW NSJ Co...
... or 08) node 63, words m+43 to m+74) Slave Verification Error Flag (bit See note 2. 01 or 09) Slave Configuration Error Flag (bit 02 or 10) Slave Remote I/O Communications Error Flag (bit 03 or 11) Master Function ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w452-e1-08_nsj_setup.pdf

マニュアル
PDF[W454-E1-04] GRT1-DRT DeviceNet™ Communications Un...
... and select Parameter – Edit – General, and then select the Smart Slave to be set. Node Address Settings and I/O Allocation Section 2-2 2. Click the Advanced Setup Button, click the Connection Tab, and select User Setup. Select Use Poll Connection and Use ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w454-e1-04_grt1-drt.pdf

マニュアル
PDF[Z047-E1-04] 3Z4SP Visual Positioning Sensor Speci...
... 2-2 Command List Operation Common function Name Description ABS Assigns absolute value to the result of expression AND ANDs two expressions ASC Converts specified character to character code CHR$ Converts specified character code to character ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z047-e1-04_3z4sp.pdf

マニュアル
PDF[Z048-E1-01] 3Z4SP Visual Positioning Sensor Refer...
...ATN Item Contents Function Determines arctangent. Format ATN () Example A!=ATN(0.5) Description Determines the arctangent in radians of . The value provided is between –π/2 and π/2. Comments ––– Reference ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z048-e1-01_3z4sp.pdf

マニュアル
PDF[Z092-E1-02] F300 Visual Inspection System Referen...
... display mode. Text display control Command 68 Section 1-1 OVL Alphabetical List Command/Function C D Operation Instruction Type Page CONT Continues execution of a program. Program execution control Command 68 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z092-02_f300.pdf

マニュアル
PDF[Z147-E1-02] F160 Vision Sensor Expert Menu Operat...
...Refer to page 215 for the list of setting items. 5. Select the item to be set. (Here, Measurement is selected as an example.) Variable0 Position Measurement Variable Data Judge Constant ← ABS SIN AND MOD ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z147-e1-02_f160.pdf

マニュアル
PDFz152-e1-02_e3x-drt21_srt21_cif11.pdf
...Remote I/O communications two-word mode Remote I/O communications two-word mode with incident light level monitoring Cannot be set. --- The DeviceNet Configurator can be used to set the connection type. The Fiber Amplifier Sensor Communication Unit supports bit-strobe, polling, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z152-e1-02_e3x-drt21_srt21_cif11.pdf

マニュアル
PDF[Z173-E1-02B] F160-2 Vision Sensor Expert Menu Ope...
...Refer to page 223 for the list of setting items. 5. Select the item to be set. (Here, Measurement is selected as an example.) Variable0 Position Measurement Variable Data Judge Constant ← AND ABS SIN MOD ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z173-e1-02b_f160-2.pdf

マニュアル
PDFz223-e1-03_e3x-drt21-s.pdf
... different protocols for remote I/O communications between master and slave devices. Connection is a unit used to manage those protocols. The connections can be set using the configurator. The DeviceNet remote I/O communications protocol supports four types of connections: Poll, Bit-Strobe, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z223-e1-03_e3x-drt21-s.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。