全 6012 件が検索されました。(3441 - 3460件を表示)

  • マニュアル

    ... are required. Linear output 4 to 20 mA Permissible load resistance 600 Ω max. Resolution Output error 4096 ±0.5% FS 1 to 5 V 500 Ω min. 4096 ±0.5% FS 1 mV/10 digit 1 kΩ min. 4096 ±1.5% FS 2-3-5 BCD Output Board Refer to Section 7 BCD Output for the terminal arrangement and interface. 19 SECTION 3 Operating Modes This section provides information on the basic functions of each operating mode. 3-1 3-2 3-3 3-4 3-5 3-6 3-7 Rotational/Circumferential Speed: f1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Absolute Ratio: f2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Ratio: ...

  • マニュアル

    ...transmission line. VDD Processor Turn OFF all terminal block switches except at the end-station. Host computer RS-485 Abbreviation RS-485 Ter- Abbreviminal ation FG – 19 – + 18 + SN751177N or equivalent 47 ...

  • マニュアル

    ... may cause welding of contact points or burning. VII Alphabetic Characters for Setting Data This manual uses the following alphabetic characters for setting data. VIII a b c d e f g h i j k l m A B C D E F G H I J ...

  • マニュアル

    ...WT30-SID16 Input Unit Input Characteristics Item Input voltage Allowable voltage range Input impedance Input current ON voltage/current characteristics OFF voltage/current characteristics Input filter Specifications 24 VDC 20.4 to 26.4 VDC 4.7 ...

  • マニュアル

    ...ASCII Character Hex. @ 40 A 41 B 42 C 43 D 44 E 45 F 46 G 47 H 48 I 49 J 4a K 4b L 4c M 4d N 4e O 4f ASCII Character Hex. P 50 Q 51 R 52 S 53 T 54 U 55 V 56 W 57 X 58 Y 59 Z [ 5a 5b \ 5c ] ^ 5d 5e _ 5f ASCII Character Hex. ` 60 a 61 b 62 c 63 d 64 e 65 f 66 g 67 h 68 i 69 j 6a ...

  • マニュアル

    ... separate ducts and sing shield lines. V Setting Date Notation The letters of the alphabet in settings data are displayed as shown below. VI a b c d e f g h i j k l m A B C D E F G H I J K L M n o p q r s t u v w x y z N O P Q R S T U V W X Y Z Revision History The revision code of this manual is given at the end of the catalog number at the bottom left of the ...

  • マニュアル

    ... measurement and leakage detection in Model KE1, single unit configuration for voltage sag detection, and the configuration of the connection between energy classification and power measurement in Model KM1 series. Chapter 1 Overview 1.4 Format standard Overview  Format standard ...

  • マニュアル

    ... of DeviceNet communication unit configurator ∙ Assignment of Model KM1/KE1 unit parameter to high-order device (PLC, PC) ∙ Assignment of data to IN and OUT areas Topology Combination of multidrop and T-branch connections possible (For main and branch lines) Communication speed 500 ...

  • マニュアル

    ...Do not reduce the brightness of the backlight so far that the display and RUN indicator cannot be seen. (This applies to lot numbers 3073 and later.) „ Compliance with (8 Directives 70 +50 10,000 +300 −300 35 100 +100 ...

  • マニュアル

    .... 2-18 Design Chapter 2 D Control Input Specifications Item Rated input voltage Input impedance Input current ON voltage OFF voltage ON/OFF response time Internal circuit Specification 24 V DC –15%/10% 4.7 ...

  • マニュアル

    ... signals Two words each for phase A, phase B, and phase Z. Signal levels Input method Counting speed 24 V DC, line-driver Phase differential ×1 Phase differential ×2 Phase differential ×4 Increment/decrement Pulse + direction Voltage 50 ...

  • マニュアル

    ...Mnemonic Instruction FUN code Upward Differentiation Downward Differentiation Page JME JUMP END 005 --- --- 110 JMP JUMP 004 --- --- 110 JSB JUMP TO SUBROUTINE 982 --- --- 390 K Mnemonic KEEP Instruction KEEP FUN code 011 Upward Differentiation --- Downward Differentiation --- Page 98 L Mnemonic Instruction FUN code Upward Differentiation Downward Differentiation Page LD LOAD --- @LD %LD 80 LD < LOAD LESS THAN 310 --- --- 129 LD LOAD NOT EQUAL 305 --- --- 129 LD <>F LOAD FLOATING NOT EQUAL 330 --- --- 353 LD <>L LOAD DOUBLE NOT EQUAL 306 --- --- 129 LD <>S LOAD SIGNED NOT EQUAL 307 --- --- 129 LD <>SL LOAD ...

  • マニュアル

    ...Input voltage 16 20.4 to 26.4 V Input response Inputs for normal input (16 points): ON delay time: 100 µs OFF delay time: 1 ms max. 8 points/common 59 Section 2-3 Coordinator Module 4.7 k IN0 750 0.047 µF 4.7 ...

  • マニュアル

    ...--- --- JME0 MULTIPLE JUMP END 516 --- --- 138 145 JMP JUMP 004 --- --- 138 JMP0 MULTIPLE JUMP 515 --- --- 145 JSB JUMP TO SUBROUTINE 982 --- --- 503 K Mnemonic KEEP Instruction KEEP FUN code 011 Upward Differentiation --- Downward Differentiation --- Page 119 L Mnemonic Instruction FUN code Upward Differentiation Downward Differentiation Page LD LOAD --- @LD %LD 95 LD < LOAD LESS THAN 310 --- --- 167 LD LOAD NOT EQUAL 305 --- --- 167 LD <>D LOAD DOUBLE FLOATING NOT EQUAL 336 --- --- 462 LD <>F LOAD FLOATING NOT EQUAL 330 --- --- 421 LD <>L...

  • マニュアル

    ...Manual name Programmable Multi-Axis Controller Hardware User’s Manual OMRON W580-E1 Model NY51-A Industrial PC Platform NY-series IPC Programmable Multi-Axis Controller Hardware User’s Manual OMRON I576-E1 Model R88M-...

  • マニュアル

    ... (with industrial Ethernet connector) Windows computer Power PMAC IDE setup tool EtherCAT master setup tool Model R88D-1SN02L-ECT EtherCAT communications Model Model CK3E- Model R88D-1SN02L-ECT Model XS5W-T421-M-...

  • マニュアル

    ...Power PMAC IDE Acontis EC-Engineer Model Version Model CK3E- Ver. 2.2 Model 3G3MX2-A2004-V1 Ver. 2.0 Model 3G3AX-MX2-ECT Ver. 1.1 Model XS5W-T421-M-K - Ver. 2.2 Ver. 2.4.3 Precautions for Correct Use Prepare the ESI file described in this section in advance. Contact your OMRON representative for information on how to procure the ESI file. Precautions for Correct Use Do not share the connection line of EtherCAT communications with other Ethernet networks. Do not use devices for Ethernet such as a switching hub....

  • マニュアル

    ...Model NX-ECC203 EtherCAT communications Model NX-ID3417 Model NX-OD3256 Model Version Model CK3E- Ver.2.2 Model NX-ECC203 Model NX-ID3417 Model NX-OD3256 Model XS5W-T421-M-K - Ver.1.4 Ver.1.0 Ver.1.0 Ver.2.2 Ver.2.4.3 Precautions for Correct Use Prepare the ESI file described in this section in advance. Contact your OMRON representative for information on how to procure the ESI file. Precautions for Correct Use Do not share the connection line of EtherCAT communications with other Ethernet networks. Do not ...

  • マニュアル

    ...Model NX-SID800 Model NX-OD3256 Model NX-SOD400 Model Version Model CK3E- Ver.2.2 Model NX-ECC203 Model NX-SL3500 Model NX-SID800 Model NX-SOD400 Model XS5W-T421-M-K SYSMAC-SE2 - Ver.1.4 Ver.1.0 Ver.1.0 Ver.1.0 Ver.1.15 Ver.2.2 Ver.2.4.3 Precautions for Correct Use Prepare the ESI file described in this section in advance. Contact your OMRON representative for information on how to procure the ESI file. Precautions for Correct Use Do not share ...

  • マニュアル

    ... changes that have been made from DT controllers. Element name Description Change ECAT[i].Enable Enabling the EtherCAT 0: Disable, 1: Enable network (2 and 3 are not supported.) Elements of low priority Not supported ECAT[i].LPIO[...