全 5978 件が検索されました。(2561 - 2580件を表示)
- マニュアル
... for the CJ2M-MD21@ z The temperature inside the control panel must be 50°C or less. z The following Connector-Terminal Block Conversion Unit and Connecting Cable must be used to wire I/O. • Connector-Terminal Block Conversion Unit: XW2B-40G4 • Connecting Cable: XW2Z-@@@...
- マニュアル
... μm (5) Cable Connection Direction (M12 Connector) 1: Straight 2: Right-angle (6) Cable Length A: 0.3 m B: 0.5 m C: 1 m D: 2 m E: 3 m G: 5 m J: 10 m K: 15 m (7) Connectors 0: M12 plug on one end 1: M12 socket on one end and M12 plug on the other end 2: M12 plugs on both ends C: M12 plug on one end and RJ45 plug on the other end D: RJ45 plugs on both ends E: M12 socket on one end and RJ45 plug on the other ...
- マニュアル
... connecting terminals are as shown in the following diagram. 2-13 2 CJ-series Analog Input Units (CJ1W-AD041-V1/081-V1) 2-4-2 Internal Circuit The following diagrams show the internal circuit of the analog input section. z Input Circuit 15 ...
- マニュアル
...-1 Introduction and Features 1-1-1 Introduction This Unit receives inputs directly from thermocouple or platinum resistance thermometers, performs PID control with two degrees of freedom, and outputs results through open collector outputs. This Unit has two types of inputs: thermocouples (R, S, ...
- マニュアル
...D D II Counter Input Z * I I Counter Input Z * On On 50% 0V Off Off Z E Z J * M aximum a llowed f requency of Z-pulses is 1 k Hz Filter Selection 10 kHz 50 kHz 500 kHz A <3 <3 <3 B >50 >10 >2 C >100 >20 >4 D >23 >4.5 >1 * Maximum allowed frequency of Z-pulses is 1 ...
- マニュアル
...0.110 ms outputs + 128 bit inputs, 128 bit outputs 0.146 ms 0.291 ms 4.674 ms Communications mode 8 1,024 word inputs, 1,024 0.013 ms + 0.018 ms + 0.035 ms + 0.567 ms + K (*1) K (*1) K (*1) word outputs + 256 bit inputs, ...
- マニュアル
... parameters. Set Reset When status is read After busy status is released When status is read When status is read TRUE: Local Unit busy (Reception is disabled because the reception buffer is more than 4/5 (= 2 ...
- マニュアル
...15 I 1 5 s I+1 4 3 s+1 I+2 1 2 s+2 : : s+3 OUT block 1 IN block 1 15 00 00 k 00 00 01 01 k+1 00 00 01 01 k+2 02 k+3 Not usable Not usable : 00 : k+4 Not usable 01 01 Not usable 01 02 k+5 l: First word in allocation size setup table s: First word in OUT block 1 ...
- マニュアル
...Zero/span adjustment Integral value calculation External 24-VDC power supply 1-3 1 Overview and Features Name Model I/O type Isolatedtype Universal Input Unit CJ1WAD04U • Resistance thermometer: Pt100, Pt1000, JPt100 • Thermocouple: ...
- マニュアル
... Block (Independent Relays) Model CJ1W-OC201 Max. Switching Capacity 2 A 250 VAC (cosφ = 1), 2 A 250 VAC (cosφ = 0.4), 2 A 24 VDC (16 A/Unit) Min. Switching Capacity 1 mA 5 VDC Relays NY-24W-K-IE (Fujitsu Takamizawa Components, Ltd.), Cannot be replaced. Service Life of Relay Electrical: 150,000 operations (24 VDC, resistive load)/100,000 operations (240 VAC, cosφ = 0.4, inductive load) Mechanical: 20,000,000 operations Service life will vary depending on the connected load. Refer to page A-71 for information on service life according to the load. ON ...
- マニュアル
...Slaves Exist Not possible Advanced General-purpose Inverters RX Series 3G3RX-V1 with EtherCAT Communications Unit 3G3AX-RX-ECT Nonsynced Slaves Exist Not possible AC Servo Drive G5-series Servo Drive with EtherCAT communications R88M-...
- マニュアル
...Learning how to use the Servomotors/ Servo Drives with built-in EtherCAT Communications. Describes the hardware, setup methods and functions of the Servomotors/Servo Drives with built-in EtherCAT Communications. AC Servomotors/Servo Drives G5 Series with I576 R88M-...
- マニュアル
... name Model numbers Manual name NJ-series CPU Unit NJ501-1500 (unit version 1.00) NJ-series CPU Unit Hardware User’s Manual (Cat. No. W500) NJ-series Power Supply Unit NJ-PA3001 EtherCAT Communications Cables XS5W-T421-CMD-...
- マニュアル
... and System Configuration of NJ/NX-series Controllers and 1S-series AC Servo 1-2 1-2-1 System Configuration and Configuration Devices Devices Used in This Guide NX1P Machine Automation Controller NX1P2-1140DT EtherCAT Communications Cable XS5W-T421-MD-...
- マニュアル
... of the parts. 4-1-1 EtherCAT Coupler Units This section gives the names of the parts of the EtherCAT Coupler Unit. (B) (D) (C) (E) (F) (G) (H) (A) (L) (I) (M) (L) (K) (F) (J) (E) Letter 4-2 Name Function (A) Marker attachment locations The locations where markers are attached. The markers made by OMRON are installed for the factory setting. Commercially available markers can also be installed. For details, refer to 6-1-8 Attaching Markers on page 6-18. (B) Unit specifications The specifications of the Unit are given. (C) NX bus connector This ...
- マニュアル
... wires. (H) Terminal block lever This lever is used to fix the terminal block on the NX Unit. (I) Unit specifications The specifications of the Unit are given. (J) Terminal block The terminal block is used to connect external devices. (...
- マニュアル
... master that supports Free-Run Mode only. NX-PG0112 and NX-PG0122 The following figure shows the system configuration of NX-PG0112 and NX-PG0122. (C) (A) (B) (D) (F) (G) (E) (M) (H) (I) (J) (K) (L) Letter 8-4 Description (A) Support Software (Sysmac Studio) (B) Connection to the peripheral USB port or built-in EtherNet I/P port on an NJ/NX-series CPU Unit (C) EtherCAT master (NJ/NX-series CPU Unit) (D) EtherCAT communications cable (E) EtherCAT Coupler Unit (F) Pulse Output Unit (NX-PG0112 or NX-PG0122) (G) Digital Input Unit NX-series ...
- マニュアル
...Errors and status of the DB Connection Service Data 1 Data 2 Data 3 Data 4 Relational Database DB Connection Service 1-2-2 DB Connection System DB Connection Instruction Field4 Data 4 Operation Logs (k...
- マニュアル
... Controller and NJ301-□□□□ NJ101-□□□□ NY-series W564 Troubleshooting Manual AC Servomotors/Servo I576 Drives G5-series with Manual 8 I577 in an NY-series Industrial PC. information on individual errors are described. R88M-...
- マニュアル
...EtherCAT CAT NETRUN NET RUN NET NETERR ERR LINK LINK/ACT /ACT PORT2 EtherNet/IP PORT3 EtherCAT (P) (O) Letter 3-2 (N) Name (M) (L) (I) (K) Function A DIP switch Used in Safe Mode or when backing up data. Normally, turn OFF all of the pins. B Push switch Unused. For future expansion, leave it unoperated. C Power supply connector Connects to the Power Supply Unit. D DIN Track mounting hooks These hooks are used to mount the Unit to a DIN Track. E Fan Unit Cools the CPU Unit internally. Refer to Fan Unit on page 3-...