全 2556 件が検索されました。(2241 - 2260件を表示)
- マニュアル
... the same as on the PC side. Parity None (default setting) Even, Odd Stop bits 1 bit (default setting), 2 bits Delimiter CR (default setting), LF, CR + LF Flow None(default setting) The flow control is not performed. RS/...
- マニュアル
...㪍 㪈 Pin No. Signal name Function 1 FG (GND) Protective frame ground 2 SD (TXD) Transmission data 3 RD (RXD) Reception data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Use a compatible connector. Recommended Model Manufacturer 38 Z550 Model Plug OMRON Corporation XM2A-0901 Hood OMRON Corporation XM2S-0911 Setup Manual setup.book Page 39 Friday, June 3, 2005 5:22 PM SECTION 3 Connecting External Devices Wiring The maximum cable length is 15 m. Standard Controller...
- マニュアル
... the same as on the PC side. Parity None (default setting) Even, Odd Stop bits 1 bit (default setting), 2 bits Delimiter CR (default setting), LF, CR + LF Flow None(default setting) The flow control is not performed. RS/...
- マニュアル
...GR Signal ground or common return SG line Send data SD ----- ----- 1 9 --- ❍ 2 Receive data Request to send RD RS ❍ --- --❍ 3 4 Can send 5V CS 5V ❍ --- --❍ 5 6 Section 3-3 RS-232C Interface Connections Connecting a Single ID Controller Only RS-232C port RS232C SYSMAC CJ1G-CPU44 PROGRAMMABLE CONTROLLER OPEN RUN ERR/ALM INH PRPHL COMM BKUP IN OUT 0 1 2 3 4 0 1 2 5 6 7 8 9 3 4 5 V600C12 RUN ERC ERP ERH T/R NORM/ERR HEAD1 HEAD2 T/R NORM/ERR SW SETTING DAT MCPWR BUSY TEST ON...
- マニュアル
...Signal name 4-4 ZS-DSU User’s Manual 8 9 Signal name NC SD(TXD) 2 2 RD(RXD) RD(RXD) 3 3 SD(TXD) RS(RTS) 4 4 NC CS(CTS) 5 5 SG(GND) NC 6 6 NC NC 7 7 RS(RTS) NC 8 8 CS(CTS) SG(GND) NC 9 9 NC 10 Section 4 RS-232C Input/Output Setting the Communication Specifications Set the RS-232C communications specifications. Match the communication specifications of the ZS-DSU to those of the external device. FUN Mode-[SYSTEM]-[COM] Setting RS232C Range LENGTH 8BIT, 7BIT (default value: ...
- マニュアル
...ID tag Link unit Max. 31 units IDRW head 24 VDC Precautions for trouble-free operation For a 1:N connection involving a link unit, it is necessary to add an normal controlled RS signal from an upstream controller to a ...
- マニュアル
... data RD Input 3 Send data SD Output 4 − 5 Signal ground 6 − 7 8 − Output SG − − Input Request send RS Output Clear to send (CS) Input 9 Comment
Normally OFF Leave this pin OPEN. Normally OPEN during service Not functioning Unused 2.1 CIDRW controller: Model V700-L21 Character format (E4 SECS I, fixed) Section 2 Communication standard ■ Cable connection example Connect the upstream controller to the CIDRW controller using the cable whose configuration is specified below. Limit the whole cable length to 15 m. Symbol DOS/V PC D-SUB... - マニュアル
...,600 bps (Use initial setting.) Data length 8 bits (Use initial setting.) Parity Even L3 Stop bits 1 bit (Use initial setting.) Header None (Use initial setting.) Footer CR (Use initial setting.) RS/CS...
- マニュアル
... Hand-held Reader Writer 4 --- --- --- 5 Signal ground SG --- Data set ready DS Hand-held Reader Writer to host device 7 Request send RS Loops inside connector 8 Enable send CS 9 --- --- 3 9 Code (See note.) Receive data 2 6 6 --- Note: The names of signals at the host device are abbreviated with codes. Note: For conversion to a 25-pin connector, the SGC-X9P/25P-2 manufactured by Sunhayato, or an equivalent, is recommended. 36 Pin No. RFID System User's Manual Section 2 Communications Preparations •Connection with the Host Device Use the following procedure to connect ...
- マニュアル
... common retrace line SG No No 5 Send data SD No Yes 3 Receive data RD Yes No 2 Request to send RS No Yes 7 Clear to send CS Yes No 8 Connector Pin Arrangement When Viewed from the Controller ID Controller Host device Shield (Shielded wire) Note 1. Ground the shielded wire on either the Controller side or the host device side to prevent operation errors. Note 2. Internally short-circuit pins 7 (RS) and 8 (...
- マニュアル
... a cordless connector (E3X-CN02). Device Net Optical Communication PLC 16 E3X-DRT21-S User’s Manual Section 1 Features and System Configuration Features Section 1 Overview ■ This unit enables a communication interface between OMRON's PLCs (...
- マニュアル
... compatible D-sub, 9-pin Name Pin No. Name - 1 SD RD 2 RD SD 3 SG ER 4 +5 V SG 5 DR 6 RS 7 CS 8 - 9 Shield wire Connector cover 0V +5 V (View of mating section) 20 V400-H111/211 User’s Manual user_en.book Page 21 Tuesday, April 17, 2007 11:35 AM Section 2 Installation and Connections Connecting a Personal Computer (V400-W22-2M/5M Cable) Section 2 Cable • Connector The connector used for V400-W22-2M and V400-W22-5M cables is a D-sub 9-pin connector (female). The ...
- マニュアル
...1 --- --- --- 2 RD Receive Data IN 3 SD Send Data 4 --- --- --- 5 SG Signal Ground --- 6 --- --- --- 7 RS Request to Send 8 CS Clear to Send IN 9 --- --- --- OUT OUT UHF RFID System User's Manual 21 SECTION 2 Specifications and Performance (3) Ethernet Interface This port is used to connect the host to the reader via Ethernet. To connect them, use the commercial cable 10/10Base-T. Connector: RJ-45 (8 pin) LINK LED LED: Link (green) /Act (orange) ACT LED SECTION 2 Reader Pin No. Name Function I/O 1 TXD(+) Transmit Data + OUT 2 TXD(-) Transmit ...
- マニュアル
...viation Input Output Pin No. Signal name • Pin Arrangement 5 SG --- --- 2 SD --- ❍ Send data 3 RD ❍ --- Receive data 4 RS --- ❍ Request to send 5 CS ❍ --- Can send 1 9 Section 2 Wiring 9 Signal ground or common return line 6 (The example at the left is for connecting a shielded cable to the host device.) ■ Connecting to the Host Device ■ Connection Example to OMRON PLC Host device ID Controller GR GR SG SG RD SD SD RD RS RS Model Manufacturer ...
- マニュアル
...Signal name 3 7 4 8 5 9 Signal name NC SD(TXD) 2 2 SD(TXD) RD(RXD) 3 3 RD(RXD) RS(RTS) 4 4 RS(RTS) CS(CTS) 5 5 CS(CTS) NC 6 6 NC NC 7 7 NC NC 8 8 NC SG(GND) NC 9 9 SG(GND) 10 Note 1: A plug type connector is used for the PLC side. ZFV-C User’s Manual 105 Section 5 Setting USB/RS-232C Communication Specifications ● RS-232C cable for connecting a personal computer • ZS-XRS2 (cable length: 2 m) Amplifier unit side PC side (...
- マニュアル
...Example 1:1 Connection Using the RS-232C Port ■ Connection to a Windows Computer Windows computer S8M Pin Name Name Pin 1 CD 2 RD 3 SD RS4 ER 232C 5 SG inter6 DR face 7 RS 8 CS 9 CI D-Sub 9-pin (female) RS-232C SD 1 terminals RD 2 SG 3 D-Sub 9-pin (male) Example 1:1 Connection Using K3SC Serial Adapters The K3SC Serial Adapters are required when the distance is over 15 m. Computer RS232C interface CD RD SD ER SG DR RS ...
- マニュアル
...-pin Name Pin No. Name - 1 SD RD 2 RD SD 3 +24V ER 4 GND SG 5 TRIG DR 6 RESET RS 7 RUN CS 8 OK/NG - 9 ERROR Shield wire Connector cover BUSY +24 V (Brown) 0 V (Blue) Not used with RS-232C communication. TRIG (Pink) RESET (Orange) RUN (Green) OK/NG (Black) ERROR (Gray) BUSY (Yellow) (View of mating section) 60 V400-F050/250/350 User’s Manual Section 5 Communicating with PC and Programmable Controller Programmable Controller A D-SUB 9-pin connector (male) is used for the cable type V400-W23 (NPN ...
- マニュアル
...Use a cable with the following pin layout, 10 Personal computer side (PC/AT compatible) (Note 1) 1 2 3 4 5 Fitting section 1 6 7 Signal name NC SD (TXD) RD (RXD) RS (RTS) CS (CTS) NC NC NC SG (GND) NC FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell 8 9 Pin No. 1 2 3 4 5 6 7 8 9 Signal name NC RD (RXD) SD (TXD) NC SG (GND) NC RS (RTS) ...
- マニュアル
...9 10 Shell 4 3 7 8 5 9 Pin No. 1 2 3 4 5 6 7 8 9 Signal name FG SD RD RS CS NC NC NC GND Shell FG Note 1: Male connector ZFX-XPT2B/XPT5B/XPT15B Signal name FG NC NC NC RDB(+) RDA(-) SDB(+) SDA(-) GND FG FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell Pin No. 1 2 3 4 5 6 7 8 9 Signal name SDA(-) SDB(+) NC NC NC RDA(-) NC RDB(+) GND Shell FG Note 1: Male connector 168 Item ZFX-XPT2A Cable ...
- マニュアル
...damage due to static electricity. Wiring diagram V500-R521B2 (Cable output type) Wiring color Signal name Function Brown TRIG External trigger signal Yellow OK READ OK signal Orange NG READ NG signal Blue ...