全 2556 件が検索されました。(2201 - 2220件を表示)

  • マニュアル

    ...D-V4 CQM1H-PRO01 CQM1-PRO01 C200H-PRO27 CS1W-KS001 Manual name CJ Series Programmable Controllers Operation Manual Contents Provides an introduction to and the specifications of SYSMAC CJ-series PLCs and describes how to install and maintain them. ...

  • マニュアル

    ... port of the Panel PC to connect the Sysmac Studio with the Machine Controller Software. 2-4-2 Configurations That Do Not Allow Online Connections This section gives information on configurations that do not provide a connection to the Sysmac Studio. 2 Routing through ...

  • マニュアル

    ... the axes group is enabled, linear interpolation is executed. MV_LIN_ABS MC_Group000 MC_Group000.Status.Ready Mv_Lin_Abs_Pos Mv_Lin_Abs_Vel Mv_Lin_Abs_Acc Mv_Lin_Abs_Dec Mv_Lin_Abs_Jrk Mv_Lin_Abs_Cs Mv_Lin_Abs_Bm Mv_Lin_Abs_Tm MC_MoveLinear AxesGroup AxesGroup Done Execute Busy Position Velocity Active Acceleration CommandAborted Deceleration Error ErrorID Jerk CoordSystem BufferMode TransitionMode Mv_Lin_Abs_D Mv_Lin_Abs_Bsy Mv_Lin_Abs_Act Mv_Lin_Abs_Ca Mv_Lin_Abs_Err Mv_Lin_Abs_ErrID If the external button turns ON (...

  • マニュアル

    .../IP port) (NX701-) These Units are used to connect to an EtherNet/IP network. OMRON PLCs CJ2 (built-in EtherNet/IP port) (CJ2H-CPU-EIP or CJ2M-CPU3) CJ-series EtherNet/IP Unit* (CJ1W-EIP21) CS-series EtherNet/IP Unit (CS1W-EIP21) (2) Twisted-pair cable The twisted-pair cable has a RJ45 Modular Connector at each end. This cable is used to connect the built-in EtherNet/IP port or EtherNet/IP Unit to an Ethernet switch. Use an STP (shielded twisted-pair) cable of category 5, 5e, or higher. (3) ...

  • マニュアル

    ...turnON/OFFandoftheorigincanbecarriedoutwiththeteachingfunction. ⑧CopyfUnction Positiondataregisteredbythepreviousoperationisalwayscalledupasthetentativevalue forthenextoperationbypressingtheUporDownkey.Thisspeedsupkeyingoperations whe皿compilingyourprogram. ●Sortingfunction EachoftheRotaryPositioner's皿tputs(8.16,0r24totaloutputs,dependingonthemodel youhaveselected)canbeactivatedrepeatedlywithinthesameprogram,uptoamaximumof 10timeseach.Whenprogrammingactivationanddeactivationofmultipleoutputs,itisnot necessarytoenterthedataintheorderoftheactivationbuttheywillbesortedautomatically. 5 ---------------------[End of Page 4260]--------------------- Sectiome2 R磁ngsandCh醐cteri8髄...

  • マニュアル

    ...Pin Field ground FG NA 1 Signal ground SG NA 7 Send data SD Output 2 Receive data RD Input 3 Send request RS Output 4 Send enable CS Input 5 Data set ready DR Input 6 Data terminal ready ER Output 20 As shown below 13 1 25 14 RS-232C Pin Assignments • Connection diagram: As shown below You cannot connect the host computer directly to more than one E5ZD Unit via the RS-232C connectors. Host computer RS-232C E5ZD RS-232C Abbr. Pin no. Pin. no. Abbr. FG 1 1 FG SG 7 7 SG SD 2...

  • マニュアル

    ...--- --- 1 Signal ground or common return line SG --- --- 7 Send data SD --- Required 2 Receive data RD Required --- 3 Request send RS --- Required 4 Can send CS Required --- 5 Data terminal ready ER --- Required (20) ID Controller Host computer GR FG SG SG SD SD RD RD RS RS ...

  • マニュアル

    ... JIS code Pin connection 1 2 Pin name GND --- Connector top view TXD SD Transmitted Data 3 RXD RD Received Data 4 RTS RS Request to Send 5 CTS CS Clear to Send 6 DSR DR Data Set Ready 7 GND SG Signal Ground 8 NC NC Protective Ground 9 (+14V) 10 (–14V) 20 DTR ER Data Terminal Ready Note Pin 9 and Pin 10 are used exclusively for the power supply of the Keyboard Terminal 3Z4SP-K1 to be connected to the Visual Controller. Do not use these pins for any other purposes. 6-1-2 RS-232C ...

  • マニュアル

    ... ground) FG ––– 1 Signal ground or common return SG ––– 7 Send data SD Output 2 Receive data RD Input 3 Request to send RS Output 4 Clear to send CS Input 5 Data set ready DR Input 6 Data terminal ready ER Output 20 Connection Diagram The following diagram shows how the E5AX is connected to the host computer using the RS-232C. Host computer RS-232C Abbreviation E5AX RS-232C Pin no. Pin Abbrevino. ation 1 1 FG SG 7 7 SG SD 2 2 SD TX RD 3 3 RD RX RS 4 4 RS ...

  • マニュアル

    ...Pin no. Ground GR ––– 1 Signal ground SG ––– 9 Send data SD Output 2 Receive data RD Input 3 Request to send RS Output 4 Clear to send CS Input 5 ID Controller Host computer GR FG SG SG SD SD RD RD RS RS ...

  • マニュアル

    ...Pin no. Ground GR ––– 1 Signal ground SG ––– 7 Send data SD Output 2 Receive data RD Input 3 Request to send RS Output 4 Clear to send CS Input 5 Data terminal not ready ER Output (20) R/W Head Host computer GR brown SG SG yellow SD SD green RD RD 13 1 RS Cable color Note ...

  • マニュアル

    ... Unit 25 13 14 1 Signal name Name 1 FG (GND) Frame ground 2 SD (TXD) Send data 3 RD (RXD) Receive data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 DR (DSR) Data set ready 7 SG (GND) Signal ground 20 ER (DTR) Data terminal ready Connect the F300-VR as shown below. SD (TXD) 2 2 SD (TXD) RD (RXD) 3 3 RD (RXD) RS (RTS) 4 4 RS (RTS) ...

  • マニュアル

    .... D. Delimiter Sets the delimiter. CR: CR only used. LF: LF only used. CR + LF: CR and LF used. F. Flow control Sets the handshake method. None: No handshaking. Xon/off: Executed by software. RS/CS: Executed using RS and ...

  • マニュアル

    ...Pin no. 25 13 14 1 Symbol Name 1 FG (GND) Frame Ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 DR (DSR) Data Settings Ready 7 SG (GND) Signal Ground 8 CD (DCD) Data Carrier Detected 20 ER (DTR) Data Terminal Ready 41 Section 2-5 Connecting Peripheral Devices Wiring Standard 25-pin Cable Connection 9-pin Cable Connection F300-E RS-232C Device RS-232C Device F300-E Symbol Pin no. Pin no. Symbol Symbol Pin no. SD (TXD) 2 2 SD (TXD)...

  • マニュアル

    ...XM2A-2501 25 13 14 1 Symbol Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 DR (DSR) Data Settings Ready 7 SG (GND) Signal ground 20 ER (DTR) Data Terminal Ready 25 Section 2-4 Connecting Power Supply Unit I/O Terminals Use only shielded RS-232C cable. Wiring Standard 25-pin Cable Connection (F309-VR) F300-E2 9-pin Cable Connection RS-232C Device RS-232C Device F300-E2 Symbol Pin no. Pin no. Symbol Symbol Pin no....

  • マニュアル

    ...Sending data SD Host device → Hand-held Reader Writer 4 --- --- --- 5 Signal ground SG --- 6 Data set enable DS 7 8 9 Request sending Clear to send --- RS CS --- Host device ← Hand-held Reader Writer Repeat p in the connector section. --- --- Transmission Specifications Transmission with the currently available V600-series Data Carriers is possible. 2-6-1 Transmission Distances Data Carrier Note Transmission distances V600-D23P53 0 to 2.5 mm V600-D23P54 0 to 4 mm V600-D23P61 0 to 11 mm V600-D23P66 0 to 17 mm (see note 2) V600-D23P66SP 0 to 12 mm V600-D23P71...

  • マニュアル

    ... pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 30 Model No. Plug XM2A-0901 Hood XM2S-0911 Section 4-3 Wiring 4-3 Wiring Use only shielded RS-232C cable. Standard Connections F150 Signal name External device Pin Pin Signal ...

  • マニュアル

    ...2-1 Amplifiers 2-1-1 Names and Functions of Components Component Names DeviceNet (CompoBus/D) Connector For connecting to DeviceNet. Data Indicators Green: Read data displayed in bit units. Red: Flashes to show error classification (bits 0 to 7 only). ...

  • マニュアル

    ... pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 4-2 Model No. Plug XM2A-0901 Hood XM2S-0911 Wiring Use only shielded RS-232C cable. Standard Connections F400 Signal name External device Pin Pin * * * * * Shield 20 Signal name Section Connection...

  • マニュアル

    ... pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 32 Model No. Plug XM2A-0901 Hood XM2S-0911 Section 4-3 Wiring 4-3 Wiring Use only shielded RS-232C cable. Standard Connections F150 Signal name External device Pin Pin Signal ...