全 1400 件が検索されました。(201 - 220件を表示)

  • カタログ

    ... DC24 1 G3RZ Accessories (Order Separately) Connection Sockets Classification Front-mounting Terminal type Appearance Model Screw terminals P2RFZ-05 Screw terminals (finger protection structure) P2RFZ-05-E Push-In Plus terminal blocks P2RF-05-...

  • カタログ

    ..._J_5_2 形G2Rと同一形状のパワー MOS FETリレー AC/DC両用、1A負荷開閉可能 ・ プッシュインPlus端子台ソケット形P2RF-05-PUとの組み合わせで配線工数60%短縮(当社実測値データ)。 ・ AC 240VまたはDC 100V、1Aの負荷開閉可能。 ・ 出力間開路時漏れ電流10μA以下。 ・ ...

  • カタログ

    ...10: 4 poles (10 terminals) 5. Terminal Type 14: 6 poles (14 terminals) Blank: Screw terminals when 3. is F type 3. Mounting Type F: Front-mounting P: Back-mounting PCB terminals when 3. is P type PU: Push-In Plus terminals 6. Coil Rated Voltage (V) 24 VDC: When 4. is ND 1 G7SA Ordering Information Main unit Relays with Forcibly Guided Contacts Terminal type Sealing Poles 4 poles PCB terminals Flux-tight 6 poles Specify the coil rated voltage when ordering. Contact configuration Coil rated voltage Model 3PST-NO, SPST-NC 12, 18, 21, 24, 48, 110 VDC...

  • カタログ

    ...イルサージ吸収用ダイオード付き ⑤端子形状無表示:③がFのとき、ねじ締め端子 ③がPのとき、プリント基板用端子 PU:プッシュインPlus端子 ⑥コイル定格電圧(V) DC24:④がNDのとき お問い合わせ 0120-919-066 または直通電話 055-982-5015(通話料がかかります) www....

  • カタログ

    ...マグネットリレーとSSRのハイブリッド化が 10A、 1,000万回開閉を実現 • プッシュインPlus端子台ソケット形PTF-08-PUとの組み合わせで配線工数60%短縮 (当社実測値データ)。 • 閉路時、しゃ断時にはトライアックで開閉。 このためチャタリングやア...

  • カタログ

    ...プロセス管 理 された設 計・製 造で、安 全 性を徹 底 追 求しています。 入力部入力部 電源・電源・回路破損回路破損 C PU C PU (制御+監視) (制御+監視) 出力部 CPUの暴走出力部 CPUの暴走 CPU CPU C PU C PU...

  • カタログ

    ...SPDT relay ・200 to 240 VAC ・24 to 48 VAC/DC SPDT relay x 2 (one for star operation/one for delta operation) 15.5 mm max. Choice No. 2 H3RN-B (H3RN) Series Combination with a P2RF-☐☐-PU Socket (width: 15.5 mm), enables mounting with no space on either side of the Socket (i.e., side by side) for usage at an ambient temperature of 55°C. Choice No. 3 90 mm max. 31 mm max. H3Y-B/H3YN-B (H3Y/H3YN) Series Combination with a PYF-☐☐-...

  • カタログ

    ...1C リレー1C x スター/デルタ 回路 15.5mm max オススメ No.2 形H3RN–B(H3RN)シリーズ製品幅15.5mmの専用ソケット形P2RF-□□-PUとの組み合わせにおいて, ソケット両側 スペース0㎜(密着取り付け)設置が可能で 55℃の周囲温度で使用できます。 オススメ No.3 31㎜ ...

  • カタログ

    ...-compatible H3RN-@-B Timers in a black design join the Compact, Multi-function H3RN Timers. • Standard multiple time ranges and multiple operating modes. • UL listed.* Conforms to CSA and CE Marking. * When used in combination with a Push-In Plus Terminal Block Socket (P2RF-@-...

  • カタログ

    ...ザインの形H3RN-□-Bをシリーズ追加。 • UL-Listed取得。 * さらにCSA、CEマークにも対応。 *プッシュインPlus端子台ソケット(形P2RF-□-PU) との組み合わせの場合規格認証対象機種などの最新情報につきましては、当社Webサイト (www.fa.omron.co.jp/)の「規格認証/適合」をご覧...

  • カタログ

    ... and contact output terminals on bottom. • Large transparent time setting knob facilitates time setting. A flat-blade and Phillips screwdriver can also be used for time setting. • Semi-multi power supply voltage. * When used in combination with a Push-In Plus Terminal Block Socket (PYF-@-...

  • カタログ

    ...用の大型つまみにより時間セットが容易。 • 電源電圧のセミマルチ化を実現。 *プッシュインPlus端子台ソケット(形PYF-□-PU-L)との組み合わせの場合。 規格認証対象機種などの最新情報につきましては、当社Webサイト (www.fa.omron.co.jp/)の「規格認証/適合」...

  • カタログ

    ...-TC Cat. No. H222-E1 2019 Released in October Low Voltage Switching Gears J7KC / J7TC / J7MC DC Electronic Circuit Protector S8V-CP Cat. No. J229-E1 Push-In Plus Terminal Block Relay Series PTF-PU Cat. No. T227-E1 Cat. No. J213-E1 Other company names and product names in this document are the trademarks or registered trademarks of their respective companies Microsoft product screen shot(s) reprinted with permission from Microsoft Corporation. The permission of Shutterstock.com was received for images that were used. Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation ...

  • カタログ

    ...Socket terminals (*1) Meaning For Screw Terminal Block Socket For Push-In Plus Terminal Block Socket Standards Model Screw Terminal Block P2RF-08/-08-E K7L-AT50 Not supported. Push-In Plus Terminal Block P2RF-08-...

  • カタログ

    ...ねじ端子台形P2RFZ-08/-08-E なし 標準用・配線用ケーブル:50m以下・漏液検知帯:10m以下 プッシュインPlus端子台形P2RF-08-PU 形K7L-AT50 19,100 (*2) 形K7L-AT50B 形K7L-AT50D ねじ端子台形P2RFZ-08/-08-E 形K7L-AT50DP あり 31,000 プッシュインPlus端子台形P2RF-08-...

  • カタログ

    ...平衡を監視。 発電機の出力電圧監視発電機の出力電圧を監視します。 三相不足電圧リレー+逆相欠相リレー 形K8DS-PU 逆相 欠相 三相不足電圧 K8DS-PU 17.5mm幅 1cリレー出力 16,500円 三相電圧リレー 形K8AK-PW 三相不足電圧 K8AK-PW 22.5mm幅 1c×2リレー出力 41,...

  • カタログ

    ...Screws One SPDT relay output K8AK-PA 17.5 mm Screws One SPDT relay output K8DS-PA 22.5 mm Screws Two SPDT relay outputs K8AK-PW 17.5 mm Screws One SPDT relay output K8DS-PU 17.5 mm Screws One SPDT relay output K8DS-PZ 17.5 mm Push-In Plus One SPDT relay output or one transistor output 22.5 mm Screws One SPDT relay output K8AK-PT 22.5 mm Screws One SPDT relay output K8AK-TS 22.5 mm Screws One SPDT relay output K8AK-TH 17.5 mm Push-In Plus One SPDT relay ...

  • カタログ

    ... リレー× 1 形K8DS-PA 19,300 円 22.5mm ねじ 1c リレー× 2 形K8AK-PW 41,000 円 17.5mm ねじ 1c リレー× 1 形K8DS-PU 16,500 円 17.5mm ねじ 1c リレー× 1 形K8DS-PZ 21,000 円 プッシュイン Plus 1c リレー× 1 or Tr. × 1 形K8DT-PZ 37,500 円 22.5mm ねじ 1c リレー× 1 形K8AK-PT 9,900 円 22....

  • カタログ

    ...Bi-power Relays LY CSM_LY_DS_E_5_18 Power-switching Compact General-purpose Relays • Wiring work can be shortened by as much as 60%* compared to conventional screw terminal sockets by combining with push-in plus terminal sockets (PTF-@-...

  • カタログ

    ...ー開閉の小型汎用リレー • 軽い挿入力と強固な引抜強度で、配線工数を削減するプッシュインPlus端子ソケット(形PTF-□-PU) との組合せで従来のねじ端子ソケットより配線工数60% 短縮。 * • 海外規格UL、CSA認定品と電気用品安全法準拠品を標準品...