ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 2533 件が検索されました。(2021 - 2040件を表示)
マニュアル
PDF[V054-E1-01] NTH25, NTH25C Programmable Terminal O...
... the Host”. Pin arrangement of 9--pin D--SUB connector The pin arrangement of the 9--pin D--SUB connector (female) is as follows: Connector pin No. 2-3-3 Abbreviation Signal Name Signal Direction (PT« host/computer) 2 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v054-01_nth25_nth25c.pdf

マニュアル
PDF[V060-E1-02] NT31-ST121(B)-E(V[]), NT31C-ST141(B)-...
... NT31/631 Custom Cable (9 to 25 Pin Connect) 9 Pin Female 25 Pin Male 3-4-2 Custom Cable for PLC5 Figure 3-17 Allen-Bradley to NT31/631 Custom Cable (25 to 9 Pin Connect) PLC PT RD 3 2 SD SD 2 3 RD 25 Pin Male 9 Pin Male SG 7 9 SG Figure 3-18 Allen-Bradley to NT31/631 Custom Cable (25 to 25 Pin Connect) PLC PT RD 3 2 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v060-02_nt31_nt631.pdf

マニュアル
PDF[V062-E1-06] NT31-ST123(B)-EV3, NT31C-ST143(B)-EV3...
... for Other Connections (Other Than the Memory Link Method) (page 76). Serial Port A 1 6 NT31/NT31C Abbreviation FG RS-232C interface Pin number Connector hood 5 Pin number Shielding wire SD SD 2 3 RD RD 3 4 RS RS 4 5 CS CS 5 6 - +5V 6 7 5G 7 8 - 8 - - 9 - - (9-pin type) 14 13 25 FG 2 * 1 Abbreviation 1 1 5G 9 PLC (host link unit) - - - ER RS-232C interface (25-pin type) * For Units that have a CTS setting selector switch, RS and CS do not have to be shorted ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v062-e1-06_nt31_31c_setup.pdf

マニュアル
PDF[V063-E1-05] NT631-ST211(B)-EV2, NT631C-ST141(B)-E...
... Connections (Other Than the Memory Link Method) (page 75). Serial Port A, B 1 6 NT631/NT631C Abbreviation FG RS-232C interface 5 Shielding wire Pin number Abbreviation 1 FG 1 2 SD SD 2 3 RD RD 3 4 RS RS 4 5 CS CS 5 6 - +5V 6 7 SG 7 8 - 8 - - 9 - - SG 9 Pin number Connector hood PLC (host link unit) (9-pin type) * - - - ER 1 14 13 25 RS-232C interface (25-pin type) * For Units that have a CTS setting selector switch, RS and CS do not have to be shorted if ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v063-e1-05_nt631_631c_setup.pdf

マニュアル
PDF[V072-E1-02] NS7-SV00[]/SV01[], NS10-TV00[]/TV01[]...
... frame 2-11 2-2 Part Names and Functions Connector Pin Arrangement of Serial Ports A and B Pin number 1 2 3 4 5 6 7 8 9 Note Signal name NC SD RD RS CS +5V NC NC SG Name Not connected. Send data Receive data Request to send Clear to send 5-V output (250 mA max.) Not connected. Not connected. Signal ground Make sure that the total current capacity of devices being supplied power is 250 mA max. before using the 5-V power supply from pin 6. The capacity of the PT's 5-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v072-02_ns12-ts_ns10-tv_ns7-sv.pdf

マニュアル
PDF[V083-E1-33] NS5, NS8, NS10, NS12, NS15 Programmab...
...When constructing an intranet, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. Take adequate measures, such as restricting physical access to network devices, by means such as locking the installation area. When using a device equipped with the ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v083-e1-33_ns5_8_10_12_15.pdf

マニュアル
PDF[V085-E1-07] NS5, NS8, NS10, NS12, NS15 Programmab...
...Pin No. 1 2 3 4 5 6 Function setting ON Terminal resistance select ON/OFF Switch between system Switch between system Not used RD control by RS select ON/OFF SD control by RS Select ON/OFF OFF 2/4 line ON 2/4 line ON Terminating resistance (on both ends of the communications path) No terminating resistance (other than both ends of the communications path) 2 line system OFF ON RS control function ON 2-3-5 NS setting Before you can connect temperature controllers, you need to store the required project in the NS. For project setting, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v085-e1-07_ns15_12_10_8_5.pdf

マニュアル
PDF[V090-E1-11] NSH5-SQR10B-V2/SQG10B-V2 Hand-held Pr...
...Forked terminal Forked terminal Forked terminal Forked terminal Forked terminal Forked terminal * Do not connect these signals. They do not function for this configuration. CN2 CN4 Signal Pin No. 1 SD 1 2 RD 2 3 RS Pin No. 4 CS 5 NC 6 0 V (SG) 7 NC 8 NC 9 SDB+ 10 SDA- 11 RDB+ 12 RDA- 13 RSB+ 14 RSA- 15 FG 16 NC 17 NC 18 19 NC NC 20 NC 3 4 CN7 Pin No. 1 2 13 Section 1-3 Special Cable Specifications CN5 CN6 Pin No. Pin No. Signal Wire size 1 3...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v090-e1-11_nsh5-sq_10b-v2.pdf

マニュアル
PDF[V091-E1-01] NT-series Programmable Terminal User'...
...Maximum communications distance 50 m (Use the NT-AL001 if the total communications distance exceeds 50 m.) RS-232C Connector Connector Pin Arrangement for RS-232C Port 24 Pin number Signal 1 2 FG RD 3 4 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v091-e1-01_nt20.pdf

マニュアル
PDF[V092-E1-13] NS(J)5, NS(J)8, NS(J)10, NS(J)12, NS1...
... check CD signal. Mitsubishi A series Computer Link Unit (RS-232C, 9pin) PT Serial Port (excluding NSH) Connector D-Sub 9 pin Male Signal Pin No. FG 1 Pin No. Signal 1 CD SD RD 2 2 RD 3 3 SD RS 4 4 DTR CS 5 5 SG +5V 6 6 DSR 7 7 RS 8 8 CS 9 9 SG * Shield Hood Connector D-Sub 9 pin Male Hood Using RS-422/485 interface on the computer link unit To communicate using RS-422/485 type of Computer Link unit, the PT requires an RS-232C/RS-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v092-e1-13_ns_nsj_nsh.pdf

マニュアル
PDF[V093-E1-07] NS-NSRCL[][] NS-Runtime Software User...
...When constructing an intranet, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. Take adequate measures, such as restricting physical access to network devices, by means such as locking the installation area. When using a device equipped with the ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v093-e1-07_ns-nsrcl.pdf

マニュアル
PDF[V202-E1-01] C200PC-ISA03-E/ISA[]3-DRM-E/ISA[]3-SR...
...Transmission distance 15 m max. Interface Conforms to EIA RS-232C Section 1-12 Specifications Pin Assignments 1 5 6 9 Pin Abbreviation Name Direction 1 FG Field ground --- 2 SD (TXD) Send data Output 3 RD (RXD) Receive data Input 4 RS (RTS) Request to send Output 5 CS (CTS) Clear to send Input 6 +5V Power supply --- 7 DR (DSR) Data set ready Input 8 ER (DTR) Data terminal ready Output 9 SG Signal ground --- Connector hood FG Field ground --- Connection Method The RS-232C port on the Expansion Option Board can be connected to a personal computer ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v202-01_c200pc-isa_3_exp01_pd024.pdf

マニュアル
PDF[V203-E1-03] ITNC-EIS01/EIS01-DRM/EIS01-CST/EIX01/...
... Arrangements This section provides the signal arrangements for each connector. COM1 and COM2 Pin No. From the side of the Open Network Controller D-sub, 9-pin, male, #4-40UNC Signal 1 CD 2 RD 3 SD 4 ER 5 SG 6 DR 7 RS 8 CS 9 CI Recommended Cables for Terminal Connections (OMRON) XW2Z-200V (D-sub, 9-pin, female, 2 m) XW2Z-500V (D-sub, 9-pin, female, 5 m) COM3 Pin No. From the side of the Open Network Controller D-sub, 9-pin, female, M2.6 Signal 1 SDA (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v203-e1-03_itnc-eis_eix.pdf

マニュアル
PDF[V228-E1-02] ITNC-EPX01(-DRM) Open Network Control...
... (COM1, COM2, or COM3) of the Open Network Controller to port A of the PT. Open Network Controller 1 2 3 4 SG 5 6 RS 7 CS 8 9 COM1 COM2 COM3 RD SD 3-7 PT 1 2 SD 3 RD 4 RS 5 CS 6 7 8 9 SG PORT A Connecting DeviceNet Cables This section explains how to connect DeviceNet cables to the Open Network Controller. 3-7-1 Connectors Model Specifications Manufacturer MSTB2.5/5-ST5.08AU For node connections. Connector screws not supplied. XW4B-05C1-H1-D For node connection and T-branch ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v228-e1-02_itnc-epx-drm.pdf

マニュアル
PDFv229-e1-03_3.pdf
... using the Special Cable. For the UPS setting in the Setup Tool, set the power failure signal as a negative logic input. UPS BU606F BU70XS Applicable Special Cable BUC10 BUC16 Special Cable Wiring (Reference) SPU Cable: BUC10/BUC16 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v229-e1-03_3.pdf

マニュアル
PDFv236-e1-04_cs1w-spu0_-v2_cj1w-spu01-v2.pdf
...-40UNC) 1 6 9 5 Connector Pin Arrangement Pin No. 1 2 3 4 5 6 7 8 9 Shell 2-5 2-5-1 Abbrev. NC RD SD NC SG NC RS CS NC FG Signal name Not used. Receive Data Send Data Not used. Signal Ground Not used. Request to Send Clear to Send Not used. Shield I/O --Input Output ------Output Input --- Handling a PC Card or Memory Card CS1W-SPU01/SPU02-V2 Inserting a PC Card 1,2,3... This section describes how to insert a PC card into the PC card slot on the...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v236-e1-04_cs1w-spu0_-v2_cj1w-spu01-v2.pdf

マニュアル
PDFv237-e1-04_ws02-sptc1-v2.pdf
... settings are checked in the following order. • FTP send settings: 0→1→2→3→5→6→7→9 • Recipe receive settings: 0→3→1→2→4→5→7→8→9 Sequential Display The connection will be checked in order of the functions from FTP Send (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v237-e1-04_ws02-sptc1-v2.pdf

マニュアル
PDF[7978637-8F] V400-H111/H211/H111-1 ハンディタイプ 2次元コードリ...
...ジョン1 ∼ 10) 操作方法 トリガボタンの押下設 定 メモリカードによる設定アップロードおよび通信メモリカード SD カードモニタ 1.8インチ TFT 液晶 画像および読取りデータ表示表示灯動作表示、 メモリカードアクセス周囲温度使用時:...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v400-h111_211_111-1_inst-7978637-8f.pdf

マニュアル
PDFv400-r1cf_r1cs_inst-4000666-9b%20.pdf
...面 30 12 フェライトコア フェライトコア 13±0.1 2-φ5.4 (貫通) 2-M5 (貫通) ■配線図形V400-R1CF/-R1CS 4-C1 SD 1 2 RD RS 3 4 CS 5 TRIG 6 NC 7 S GND 8 VCC −(注) OK −(注) NG 2次元コードリーダ 8 信号方向 ■取付金具の装着 ご使用に際してのご承諾事項 設置場所に取付...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v400-r1cf_r1cs_inst-4000666-9b .pdf

マニュアル
PDF[V469-E1-04] NS → NA Replace Guide
... Corporation in Japan and other countries for OMRON factory automation products. Microsoft, Windows, Visual Basic, and Excel are either registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA. The ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v469-e1-04_ns_na_replace.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。