PDF[Z140-E1-02] V530-R150E-2/R150EP-2 2-Dimensional C...
...NT-AL001 Signal NT-AL001 Signal Pin No. Pin No. SG (GND) 2 2 SG (GND) SDB 3 3 SDB SDA 4 4 SDA RDB 5 5 RDB RDA 6 6 RDA Connection 3 The wiring required between the NT-AL001 on the host side and the NT-AL001 on the V530-R150 side is shown below. NT-AL001 on host side Signal 66 NT-AL001 on V530-R150 side Signal Pin No. Pin No. SG (GND) 2 2 SG (GND) SDB 3 3 SDB SDA 4 4 SDA RDB 5 5 RDB ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z140-e1-02_v530-r150e-2_-r150ep-2.pdf

マニュアル
PDF[Z155-E1-02] V530-R150E(P)-3 2-Dimensional Code Re...
...NT-AL001 Signal NT-AL001 Signal Pin No. Pin No. SG (GND) SDB 2 3 2 3 SG (GND) SDB SDA 4 4 SDA RDB 5 5 RDB RDA 6 6 RDA Connection 3 The wiring required between the NT-AL001 on the host side and the NT-AL001 on the V530-R150 side is shown below. NT-AL001 on host side Signal 96 NT-AL001 on V530-R150 side Signal Pin No. Pin No. SG (GND) 2 2 SG (GND) SDB 3 3 SDB SDA 4 4 SDA RDB 5 5 RDB ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z155-e1-02_v530-r150e-3_r150ep-3.pdf

マニュアル
PDF[1660639-6E] E5AN-H デジタル調節計 取扱説明書 (日/英語)
... default alarm type is "2" e333 (E333) 0.0 25.0 Scaling Upper Limit (only when setting analog input) 2 *6 ON OFF 25.0 0.2 0 13 RS-422 RDB 11 RDA 12 SG 13 SDB 21 SDA 22 Input Type *3 X ON OFF 0 *6 X ON OFF X alt1 SP X PV change rate alarm 15 *6 SP X ON OFF 23 POWER ON off ON OFF 3 Operation Level Vary with "L", "H" values *6 RSP absolute value upper limit 14 on SP ON OFF 8 13 L H ON OFF st *6...

https://www.fa.omron.co.jp/data_pdf/mnu/e5an-h_inst-1660639-6e.pdf

マニュアル
PDF[2153002-0A] E5AN-HT デジタル調節計 取扱説明書 (日/英語)
...28 18 9 29 19 10 30 20 DO NOT USE DO NOT USE − + RS-485 11 B(+) A(−) 12 DO NOT USE 13 RS-422 RDB RDA 13 SG 21 SDB 22 SDA 11 12 21 22 21 B(+) A(−) 22 14 23 C + DO NOT USE A DO NOT USE V B − DO NOT B USE EV3 Auxiliary output 3 15 W CT2 6 - Auxiliary output 3 O CT1 The E5@N-HT is set for a K thermocouple Auxiliary output 2 (input type of 5) by default. If a different sensor is used, an input error (s....

https://www.fa.omron.co.jp/data_pdf/mnu/e5an-ht_inst-2153002-0a.pdf

マニュアル
PDF[1661077-6E] E5EN-H デジタル調節計 取扱説明書 (日/英語)
...A(-) 11 12 15 - C + DO NOT DO NOT USE USE A DO NOT + USE V mA B - - Auxiliary output 1 10 RS-422 RDB 11 RDA 12 SG 13 SDB 21 SDA 22 EV3 W CT2 Auxiliary output 1, 2, 3 O CT1 5 Auxiliary output 3 14 Potentiometer 14 24 RS-232C SD RD 12 SG 13 DO NOT USE 21 DO NOT USE 22 11 B + DO NOT USE DO NOT USE A heater burnout alarm, Heater Short + alarm, heater overcurrent alarm, or Transfer output input alarm is output to the output to which the alarm 1 ...

https://www.fa.omron.co.jp/data_pdf/mnu/e5en-h_inst-1661077-6e.pdf

マニュアル
PDF[5636569-3C] MX-Z2000H-V1/Z2050H-V1/Z2055H-V1 ファイバ...
...号用グランドです。 SG(GND) 外部機器の SG(GND)を接続します。 8 − 9 RDB(+) 外部機器からのデータを入力します。 10 RDA(−) 外部機器からのデータを入力します。 11 SDB(+) コントローラからデータを出力します。 RS-422A 12 SDA(−) コントローラからデータを出力します。...

https://www.fa.omron.co.jp/data_pdf/mnu/mx-z2000h-v1_-z2050h-v1_-z2055h-v1_inst-5636569-3c.pdf

マニュアル
PDF[5636570-7C] MX-Z2000H-V1/Z2050H-V1/Z2055H-V1 Fibe...
... used) 7* SG (GND) A signal ground. Connects the SG (GND) terminal on the external device. 8  (Not used) RS-422A 1 1 9 RDB (+) Enters data from the external device. 10 RDA () 11 12 13 14 15 SDB (+) SDA (−)    Enters data from the external device. Outputs data from the controller. Outputs data from the controller. (Not used) (Not used) (Not used) * Even when RS-422A is selected, Pin No. 7 is still used as the SG (GND) terminal. Do not use the RS-232C terminals and RS-422A terminals at the same time....

https://www.fa.omron.co.jp/data_pdf/mnu/mx-z2000h-v1_-z2050h-v1_-z2055h-v1_inst-5636570-7c.pdf

マニュアル
PDF[5377009-0B] NX-HAD401/HAD402 アナログI/Oユニット 取扱説明書(安全...
... that supply power. Take appropriate measures to ensure that the specified power with the rated voltage and frequency is supplied in locations If you use the RS-422A/485 port, check the polarity before you connect the cable. The polarity of the SDA/SDB and ...

https://www.fa.omron.co.jp/data_pdf/mnu/nx-had401_had402(safetyprecautions)_inst-5377009-0b.pdf

マニュアル
PDFAdditional NX Unit Power Supply Unit
... that supply power. Take appropriate measures to ensure that the specified power with the rated voltage and frequency is supplied in locations. ● If you use the RS-422A/485 port, check the polarity before you connect the cable. The polarity of the SDA/SDB and ...

https://www.fa.omron.co.jp/data_pdf/mnu/nx-htc(precautionsforcompliancewith ulcsastandards,eudirectivesanduklegislation)_inst-3615353-3b.pdf

マニュアル
PDF[5691190-6A] NX-TC 温度調節ユニット 取扱説明書(UL/CSA規格適合注意とEC指...
... supply power. Take appropriate measures to ensure that the specified power with the rated voltage and frequency is supplied in locations z If you use the RS-422A/485 port, check the polarity before you connect the cable. The polarity of the SDA/SDB and ...

https://www.fa.omron.co.jp/data_pdf/mnu/nxseries(nx-tc)(precautionsforcompliancewithulstandardsandcsastandardsandeudirectives)_inst-5691190-6a.pdf

マニュアル
PDF[O010-E1-01] FQM1-CM001/MMP21/MMA21 Flexible Motio...
... to 8 28 Power supply for external outputs 0 to 8 29 31 Not used. Not used. 30 32 Not used. Not used. 33 35 SDA− (RS-422A) SDB+ (RS-422A) 34 36 RDA− (RS-422A) RDB+ (RS-422A) 37 39 Not used. Not used. 38 40 Not used. Not used. 67 Section 3-3 Wiring Module Connectors FQM1-MM@21 Motion Control Modules General-purpose I/O 26-pin Connector Pin No. 26 24 Not used. Address External input 6 CIO 0000.06 CIO 0000.01 21 External input 7 CIO 0000.07 CIO 0000.02 19 External ...

https://www.fa.omron.co.jp/data_pdf/mnu/o010-e1-01_fqm1-cm001_mmp21_mma21.pdf

マニュアル
PDF[O012-E1-03] FQM1-CM002/MMP22/MMA22 Flexible Motio...
... to 8 28 Power supply for external outputs 0 to 8 29 31 Not used. Not used. 30 32 Not used. Not used. 33 35 SDA− (RS-422A) SDB+ (RS-422A) 34 36 RDA− (RS-422A) RDB+ (RS-422A) 37 39 Not used. Not used. 38 40 Not used. Not used. 113 Section 3-3 Wiring Module Connectors FQM1-MM@22 Motion Control Modules General-purpose I/O 26-pin Connector Pin No. 26 24 Not used. Address External input 6 CIO 2960.06 CIO 2960.01 21 External input 7 CIO 2960.07 CIO 2960.02 19 External ...

https://www.fa.omron.co.jp/data_pdf/mnu/o012-e1-03_fqm1-com_mm.pdf

マニュアル
PDF[P641-E1-01] 3G3MX2-V1 Multi-function Compact Inve...
... details on cable wirings. Check connector configurations and signal lines (pin assignments) before wiring. ■Connector configurations and signal lines (pin assignments) CJ1W-SCU42 Serial Communications Unit applicable connector: Terminal block Pin No. Symbol Signal name Input/Output 1(See note 1.) ...

https://www.fa.omron.co.jp/data_pdf/mnu/p641-e1-01_3g3mx2-v1.pdf

マニュアル
PDF[R123-E1-01] FB Library Programmable Controller St...
..., R7D-AP††H/-AP††L Terminal Resistance Treatment In case of 4-wire (RS422): (Use RT only for the final servo) R7D-APA5L CJ1W-SCU…… Port1 Terminal Resistance RT CJ1W-CIF11 SDA RXD- SDB RXD+ RDA TXD- RDB TXD+ R7D-APA5L Terminal Resistance RT RXDRXD+ TXDTXD+ In case of 2-wire RS485: (Use terminal resistance only for the final driver) R7D-AP01L CJ1W-SCU…… Port1 RT Terminal Resistance CJ1W-CIF11 SDA RXD- SDB RXD+ ...

https://www.fa.omron.co.jp/data_pdf/mnu/r123-e1-01_fb_library.pdf

マニュアル
PDF[SBCA-031] SmartFBライブラリ 立ち上げガイド
...。 (最終端となるサーボのみRTを配線します。 ) R7D-APA5L CJ1W-SCU□□ P ort1 終端抵抗 RT CJ1W-CIF11 S DA RXD- S DB RXD+ RDA TXD- RDB TXD+ R7D-APA5L 終端抵抗 RT RXDRXD+ TXDTXD+ RS485 2線式の場合の配線方法(最終端のドライバのみ終端抵抗を配線します。 ) R7D-AP01L CJ1W-SCU□□ P ort1 RT 終端抵抗 CJ1W-CIF11 S DA RXD- S ...

https://www.fa.omron.co.jp/data_pdf/mnu/sbca-031_cs1-cpu_cj1-cpu_ws02-cxpc1-jv5.pdf

マニュアル
PDF[SBCA-354M] CP1E-E□□(S)D□-□/N(A)□□D□-□/N□□S□D□-□ C...
...ード(形 CP1W-CIF11/ 形 CP1W-CIF12) 表面 裏面 通信状態表示LED CPU ユニット接続コネクタ動作設定用ディップスイッチ COMM RDA- RDB+ SDA- SDB+ FG RS-422A/485 コネクタ  RS-422A/485 端子台端子台のねじは0.28N・mで締め付けてください。 ...

https://www.fa.omron.co.jp/data_pdf/mnu/sbca-354m_cp1e.pdf

マニュアル
PDF[SBCA-422H] NX-CIF□□□ コミュニケーションインタフェースユニット ユーザーズマニ...
...ェースユニット使用時 • RS-422A/485 の接続時は、必ず極性を確認の上、結線してください。 相手機器によって、略称 SDA/SDB、RDA/B と信号の +/− 極性が逆になるものがあります。 NX シリーズ コミュニケーションインタフェースユニット ユーザーズマニュ...

https://www.fa.omron.co.jp/data_pdf/mnu/sbca-422h_nx-cif.pdf

マニュアル
PDF[SBCA-448N] NX1P2-□□□□□□(1) CPUユニット ユーザーズマニュアル(ハード...
...ションボード 3-3-1 形式と仕様 NXシリーズ 形NX1P2 CPUユニット 3 3-3-1 形式と仕様 COMM COMM SG0 RD SD RDA- RDB+ SDA- SDB+ SHLD ER SG1 DR RS CS SHLD RS-232C RS-422A/485 オプションボード (形NX1W-CIF01) オプションボード (形NX1W-CIF11/12) シリアル通信用オプションボードの共通の仕様...

https://www.fa.omron.co.jp/data_pdf/mnu/sbca-448n_nx1p2.pdf

マニュアル
PDF[SBCA-449F] NX1P2-10□□□□(1)/11□□□□(1)/90□□□□(1) CP...
.../IP PORT2 EtherCAT 1 2 OUT ERR ERR シリアル通信用オプションボード 3-2 OUT VI1 I I1 VI2 I I2 COM IN RDA- RDB+ SDA- SDB+ SHLD ERR IN OUT オプションボード VI1 I I1 VI2 I I2 COM VO1 VO2 COM COMM ER SG1 DR RS CS SHLD VO1 VO2 COM COMM SG0 RD SD アナログ入出力用オプションボード NX シリーズ 形 NX1P2 CPU ユ...

https://www.fa.omron.co.jp/data_pdf/mnu/sbca-449f-web1_nx1p2.pdf

マニュアル
PDF[SBCA-477C] CP2E-E□□D□-□/S□□D□-□/N□□D□-□ CPUユニット ユ...
...形 CP1W-CIF11/ 形 CP1W-CIF12-V1) 表面 裏面 通信状態表示LED CPU ユニット接続コネクタ COMM 動作設定用ディップスイッチ RDA- RDB+ SDA- SDB+ FG RS-422A/485 端子台 z RS-422A/485 端子台端子台のねじは0.28N・mで締め付けてください。 FG ...

https://www.fa.omron.co.jp/data_pdf/mnu/sbca-477c_cp2e.pdf