ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索

検索結果を絞り込む

絞り込み解除
全文検索:全 311 件が検索されました。(21 - 40件を表示)
マニュアル
PDF[W143-E1-07] C200H-LK, C500-LK, 3G2A5-LK, 3G2A6-LK...
... but C500-LK203 and insulated types) The following table details the pin connections for a RS-422 interface. Signal* Send data A Send data B Receive data A Receive data B Signal ground Frame ground Symbol SDA SDB ...

https://www.fa.omron.co.jp/data_pdf/mnu/w143-07_c200h-lk_c500-lk_3g2a6-lk.pdf

マニュアル
PDF[W356-E1-08] CPM2C Programmable Controller Operati...
... CPM2C. 73 Section 2-2 Unit Components 1,2,3... 1. RS-422/RS-485 Port Connects CompoWay/F general-purpose communications components and SYSWAY Temperature Controllers and Digital Panel Meters. RS-422 Pin Assignments RS-485 Pin Assignments ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w356-e1-08_cpm2c.pdf

マニュアル
PDF[N096-E1-01] K3NX, K3NV, K3NH, K3NR, K3NP, K3NC Co...
...Be sure to turn ON the terminator switches only in the devices at each end of the transmission line. Host computer RS-422 Terminator Processor Abbreviation RS-422 FG The terminator must have a minimum resistance of 100 Ω. ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/n096-01_k3nx_k3nv_k3nh_k3nr_k3np_k3nc.pdf

マニュアル
PDF[SCEI-708A] K3N□ 通信出力タイプ 操作マニュアル
...は、合計で最大500mです。 ・ケーブルには、シールド付ツイストペア線(AWG28以上)をご使用ください。 終端抵抗 略称 FG RDA RDB SDA SDB SG 終端抵抗 (ターミネータ) ターミネータは合成して 100Ω以上にしてください。 シールド線 デジタルパネルメータ側 RS-422 ピ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/scei-708a_k3n_com.pdf

マニュアル
PDF[H186-E1-06] E5[]C-T (Programmable Type) Digital T...
...NO. RS-422A Converter CJ1W-CIF11 ABC Commercially available USB cable E5CC-T No.0 PORT1 FG L1 E5CC-T No.1 E5CC-T No.2 SDA- SDB+ AC100-240V INPUT RDA- RDB+ L2/N Peripheral (USB) port C PORT2 RUN OUTPUT AC240V DC24V 25 0 C 25 0 C 25 0 The application procedure is given below. START Set the switches on the CJ1W-CIF11 and wire it to the E5CC-T Controllers. Set up the PLC. Use the CX-Programmer to set up communications on the CJ1W-SCU21-V1 to enable communicating with the E5CC-T Controllers. E5@...

https://www.fa.omron.co.jp/data_pdf/mnu/h186-e1-06_e5_c-t.pdf

マニュアル
PDF[P520-E1-02] E5[]D, E5[]C, E5[]C-T Digital Temprat...
...Input/Output 13 B(+) Input/Output 14 A(-) Input/Output 1-12 15-18 Serial Communications Unit (CJ1W-SCU42) applicable connector: Terminal block Pin No. Symbol Signal name Input/Output 1 (See note 1.) RDA...

https://www.fa.omron.co.jp/data_pdf/mnu/p520-e1-02_e5_d_e5_c_e5_c-t.pdf

マニュアル
PDF[SGTD-743E] E5□C-T デジタル調節計(プログラムタイプ) 通信マニュアル
...-CIF11 ABC 市販の USBケーブル 形E5CC-T No.0 PORT1 FG L1 SDA- SDB+ AC100-240V INPUT 形E5CC-T No.1 形E5CC-T No.2 RDA- RDB+ L2/N ぺリフェラル(USB) ポート C PORT2 RUN OUTPUT AC240V DC24V 25 0 C 25 0 C 25 0 RS-485 (注) CX-Programmer と USB ドライバのインストール方法は、「CX-Programmer ユーザーズマニュアル」 (SBCA-337) を参照...

https://www.fa.omron.co.jp/data_pdf/mnu/sgtd-743e_e5_c-t.pdf

マニュアル
PDF[W375-E1-05] CS1W-LC001 Loop Control Unit (Ver.2.5...
...-485 connections : SW1-3: ON, SW1-4: ON (2-wire, RS-485) ES100X (unit No. 0) RS-485 Signal Pin No. GRD 1 SG 2 SDB 3 SDA 4 RDB 5 RDA 6 Terminal block ・ RS-485 Signal SG RDBRDA+ Terminal 15 17 16 Terminal block Shield ES100X (unit No. 30) RS-485 Signal SG RDB ...

https://www.fa.omron.co.jp/data_pdf/mnu/w375-e1-05_cs1w-lc001.pdf

マニュアル
PDF[SCCP-303D] NT20S, NT600S, NT30(C), NT620S, NT620C...
...ポートA(RS-232C専用) または シリアルポートB(RS-232C) 計算機リンクユニット PT SW1 PRINTER RESET CONTRAST RS-232C SDA SDB RDA RDB 25ピンコネクタ /9ピンコネクタ 24VDC 三菱A シリーズシーケンサ GR RS-232C 25ピンコネクタ /9ピンコネクタ RS-232Cコネクタ付ケーブル (最大ケ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/sccp-303d-10_nt.pdf

マニュアル
PDF[SBCA-313P] CS/CJ/NSJシリーズ CPUユニット ユーザーズマニュアル(プログラミ...
...コミュニケーションボード 形 C200HW-COM□□ 配線を以下のように変更してください。 ・SDA:9 ピン→1 ピン・SDB:5 ピン→2 ピン・RDA:6 ピン→6 ピン・RDB:1 ピン→8 ピン・SG:3 ピン→配線せず・FG:7 ピン→コネクタフード変更なし(そのまま使用可能) CVM1/CV シリーズ CPU ユニ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/sbca-313p-1_cs_cj_prog.pdf

マニュアル
PDF[SBCZ-688C] E5AR, E5ER デジタル調節計編 CJシリーズ 汎用シリアル接続ガイド...
...アルコミュニケーション デジタル調節計 ユニット(形 CJ1W-SCU42) (形 E5AR) RS-422A/ 信号名 ピン No. ピン No. 485 イ ン RDA- 1 F列 タフェー RDB+ 2 ス SDA- 3 1 B(+) SDB+ 4 2 A(-) FG 5 3-6 端子台コネクタ 信号名 RS-485 インタフェース 端子台 ※形 E5ER(-T)の場合は C 列になります。...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/sbcz-688c-1_e5ar_e5er.pdf

マニュアル
PDF[V033-E1-05] NT620S, NT620C Programmable Terminal ...
... direction Signal input and output is relative to the NT-AL001. Terminal Block Pin No. Signal Name 8 Request to send (A) CSA (CS–) 7 Request to send (B) CSB (CS+) 6 Receive data (A) RDA (RD–) f 5 Receive data (B) RDB (RD+) f 4 Send data (A) SDA (SD–) f 3 Send data (B) SDB (SD+) f 2 Signal ground SG (GND) 1 Functional ground Signal Direction Abbreviation Input Output f f – – – – * The CSA and CSB signals are for special applications. Terminal Screws and Crimp Terminals The terminal screws are M3 screws. Use M3 size crimp terminals....

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v033-05_nt620s_nt620c.pdf

マニュアル
PDF[W394-E1-16] CS/CJ/NSJ Series Programmable Control...
... below. programs without alteration as long as the same communications settings (e.g., baud SDA: Pin 9 to pin 1 rate) are used. It may be necessary, however, SDB: Pin 5 to pin 2 to change programs to allow for different text ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w394-e1-16_cs_cj_nsj.pdf

マニュアル
PDF[H142-E1-09] EJ1 Modular Temperature Controllers U...
...: 50 mA − A3 B5 A5 SUB1 B6 COM Port C RDB (+) B (+) B7 − A6 Contact input Non-contact input A7 SD A8 RD A9 SG SDB (+) B8 RDA (−) A (−) DO NOT USE RS-422 RS-485 B9 RS-232C SDA (−) DO NOT USE RS-422 · Terminals A10 and B10 are not used on models with screw-less clamp terminals. Do not connect anything to these terminals. 19 Section 2-2 Wiring Terminals EDU Port A connector Port A connector Port A on terminal block B (+) These two ports cannot be used at the same time. 1 RS-485 Port ...

https://www.fa.omron.co.jp/data_pdf/mnu/h142-e1-09_ej1.pdf

マニュアル
PDF[H157-E1-08] E5AN-H, E5CN-H, E5EN-H (Advanced Type...
...voltage input terminals are wired incorrectly. Section 2-2 Wiring Terminals E5AN/EN-H Controllers Option Units Communications E53-EN01 RS-232C SD 11 RDB 11 B (+) 11 12 RD 12 RDA 12 A (−) 12 13 SG 13 SG 13 DO NOT USE 13 DO NOT USE 21 SDB 21 B (+)*2 21 DO NOT USE 22 SDA 22 A (−) 22 *2 22 Input power supply 1 21 11 2 22 12 3 23 13 Potentiometer CT1 25 15 6 26 16 7 27 17 8 28 18 9 29 19 10 30 20 Control output 2 CT2 Auxiliary output ...

https://www.fa.omron.co.jp/data_pdf/mnu/h157-e1-08_e5cn-h_e5an-h_e5en-h.pdf

マニュアル
PDF[H159-E1-04] E5AN-H, E5CN-H, E5EN-H (Advanced Type...
...1.1 Overview of Communications Methods Host E5AN/EN-H (No. 0) RS-422 Shield No. Terminator × 2 (240 Ω, 1/2 W) E5AN/EN-H (No. 30) Overview RS-422 RS-422 No. RDA 22 SDA 22 SDA RDB 21 SDB 21 SDB SDA 12 RDA...

https://www.fa.omron.co.jp/data_pdf/mnu/h159-e1-04_e5cn-h_e5an-h_e5en-h.pdf

マニュアル
PDF[H169-E1-06] E5CN-HT, E5AN-HT, E5EN-HT (Programmab...
...11 2 22 12 3 23 13 4 24 14 Event Inputs (See note.) EV2 EV1 Control output 1 11 SD 11 RDB 11 12 RD 12 RDA 12 A (− ) 13 SG 13 SG 13 DO NOT USE 21 DO NOT USE 21 S DB 21 B (+) 22 DO NOT USE 22 S DA 22 A (− ) 14 O CT1 25 Auxiliary output 3 15 Auxiliary output 3 15 CT2 6 26 16 7 27 17 8 28 18 29 19 10 30 20 16 C DO NOT USE Auxiliary output 2 9 Relay output SPDT, 250 VAC, 3 A (resistive ...

https://www.fa.omron.co.jp/data_pdf/mnu/h169-e1-06_e5_n-ht.pdf

マニュアル
PDF[H170-E1-02] E5CN-HT, E5AN-HT, E5EN-HT (Programmab...
...1.1 Overview of Communications Methods Host E5AN/EN-HT (No. 0) RS-422 Shield No. Terminator × 2 (240 Ω, 1/2 W) E5AN/EN-HT (No. 30 Overview RS-422 RS-422 No. RDA 22 SDA 22 SDA RDB 21 SDB 21 SDB SDA 12 RDA...

https://www.fa.omron.co.jp/data_pdf/mnu/h170-e1-02_e5cn-ht_e5an-ht_e5en-ht.pdf

マニュアル
PDF[H225-E1-04] E5[]D Digital Temperature Controllers...
...UNIT NO. RS-422A Converter CJ1W-CIF11 ABC Commercially available USB cable E5CD No.0 PORT1 FG L1 E5CD No.1 E5CD No.2 SDA- SDB+ AC100-240V INPUT RDA- RDB+ L2/N 6 Peripheral (USB) port PORT2 RUN OUTPUT AC240V DC24V The application procedure is given below. START Set the switches and wire the system. Set up the PLC. Set up the E5@D Controllers. Check operation. Set the switches on the CJ1W-CIF11 and wire it to the E5CD Controllers. Use the CX-Programmer to set up communications on the CJ1W-SCU21-V1 to enable communicating with the ...

https://www.fa.omron.co.jp/data_pdf/mnu/h225-e1-04_e5_d.pdf

マニュアル
PDF[P540-E1-01] KM50 Smart Power Monitor CJ-series Ge...
... Applicable connector: Terminal block Applicable connector: Terminal block Connector Pin Layout Pin No. 1 (See note 1.) 2 (See note 1.) 3 (See note 1.) 4 (See note 1.) 5 (See note 2.) Symbol ...

https://www.fa.omron.co.jp/data_pdf/mnu/p540-e1-01_km50.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。