マニュアル
PDF[W536-E1-10] NX-EIC202 EtherNet/IP™ Coupler Unit U...
... achieved. Perform the following processing if noise countermeasures are necessary. Program the Slave Terminal Status (refer to 9-2-3 I/O Allocation Information on page 9-12) and/or Unit status CIO bits as an interlock condition in the user program. Refer to the ...

https://www.fa.omron.co.jp/data_pdf/mnu/w536-e1-10_nx-eic202.pdf

マニュアル
PDF[W539-E1-08] NJ501-4500/4400/4320/4310/4300 NJ Rob...
..., – 750.0, 0.0, 0.0, 30.0 ) S1 y y TC MCS S1 x TC z RZ2 S1 S0 x z TC y TC S0 x TC TCP1 P2 0 CS yTCS0 zTCS0 yTCS1 xTCS0 zTCS1 TCP0 P0 TCP1 zT Transition TCP0 xTCS1 P1 P0 = ( X 0, Y 0, Z 0, R x , R y , R z ) 0 0 0 P1 = ( X 1 , Y 1, Z 1, R x , R y , R z ) 1 1 1 P2 = ( X 2 , Y 2, Z 2, R x , R y , R z ) 2 2 2 Precautions for Correct Use Robot tools ...

https://www.fa.omron.co.jp/data_pdf/mnu/w539-e1-08_nj501-4500_4400_4320_4310_4300.pdf

マニュアル
PDF[W540-E1-08] NX-CIF[][][] Communications Interface...
...CPU Unit connection --- 1-8 Communications Coupler Unit --- Usability Usable NX-series Communications Interface Units User’s Manual (W540) 1 Features and System Configuration Communications master • NJ/NX-series CPU Unit • NY-series Industrial PC ...

https://www.fa.omron.co.jp/data_pdf/mnu/w540-e1-08_nx-cif.pdf

マニュアル
PDF[W578-E1-14] NX1P2-[][][][][][](1) CPU Unit User's...
... Serial Communications Units. CX-Designer The CX-Designer is used to create screens for NS-series PTs. If the NJ/NX-series Controller is a target device, you may also use Sysmac Studio version 1.10 or higher. Use the Network Configurator if a ...

https://www.fa.omron.co.jp/data_pdf/mnu/w578-e1-14_nx1p2.pdf

マニュアル
PDF[W579-E1-06] NX1P2-10[][][][](1)/11[][][][](1)/90[...
...I I2 COM RDA- RDB+ SDA- SDB+ SHLD Option Board ERR ERR IN OUT OUT VI1 I I1 VI2 I I2 COM VO1 VO2 COM COMM IN ER SG1 DR RS CS SHLD VO1 VO2 COM COMM SG0 RD SD Analog I/O Option Board NX-series NX1P2 CPU Unit Built-in I/O and Option Board User’s Manual (W579) 3 Option Boards 3-1-1 Serial Communications Option Boards The following table shows the types and summary specifications of Serial Communications Option Boards. NX1W-CIF01 NX1W-CIF11 COMM COMM SG0 RD SD Communications port Number of ports Communications ...

https://www.fa.omron.co.jp/data_pdf/mnu/w579-e1-06_nx1p2.pdf

マニュアル
PDF[W593-E1-14] NX102-[][][][] CPU Unit User's Manual...
... Serial Communications Units. CX-Designer The CX-Designer is used to create screens for NS-series PTs. If the NJ/NX-series Controller is a target device, you may also use Sysmac Studio version 1.10 or higher. Use the Network Configurator if a ...

https://www.fa.omron.co.jp/data_pdf/mnu/w593-e1-14_nx102.pdf

マニュアル
PDF[W613-E1-03] CP2E-E[][]D[]-[]/S[][]D[]-[]/N[][]D[]...
...……D…-… A model of CPU Unit that supports Ethernet connection and enhanced positioning functions such as 4-axis linear interpolation and pulse. The CP Series is centered around the CP1H, CP1L, CP1E and CP2E CPU Units and is designed with the same basic architecture as the ...

https://www.fa.omron.co.jp/data_pdf/mnu/w613-e1-03_cp2e.pdf

マニュアル
PDF[W614-E1-03] CP2E-E[][]D[]-[]/S[][]D[]-[]/N[][]D[]...
...……D…-… A model of CPU Unit that supports Ethernet connection and enhanced positioning functions such as 4-axis linear interpolation and pulse. The CP Series is centered around the CP1H, CP1L, CP1E and CP2E CPU Units and is designed with the same basic architecture as the ...

https://www.fa.omron.co.jp/data_pdf/mnu/w614-e1-03_cp2e.pdf

マニュアル
PDFMachine Automation Controller NX-series
... point of route path is the CPU Unit, it is necessary to set the route path that starts from the CPU Unit and passes through the NX-series EtherNet/IP Unit. The maximum number of levels of CIP routing via the ports is eight for any combination of ...

https://www.fa.omron.co.jp/data_pdf/mnu/w627-e1-05_nx-eip201.pdf

マニュアル
PDFMachine Automation Controller NX-series
... Serial Communications Units. CX-Designer The CX-Designer is used to create screens for NS-series PTs. If the NJ/NX-series Controller is a target device, you may also use Sysmac Studio version 1.10 or higher. Use the Network Configurator if a ...

https://www.fa.omron.co.jp/data_pdf/mnu/w629-e1-07_nx502-1_00.pdf

マニュアル
PDF[Z129-E1-02] V600-HAM42-DRT Intelligent Flag III (...
...2-1 Amplifiers 2-1-1 Names and Functions of Components Component Names DeviceNet (CompoBus/D) Connector For connecting to DeviceNet. Data Indicators Green: Read data displayed in bit units. Red: Flashes to show error classification (bits 0 to 7 only). ...

https://www.fa.omron.co.jp/data_pdf/mnu/z129-e1-02_v600-ham42-drt.pdf

マニュアル
PDF[Z167-E1-06A] V640-HAM11-V2/HS61, V700-L11/L22 *V6...
...2 RD SD 3 3 SD NC 4 4 NC SG 5 5 SG NC 6 6 NC RS 7 7 RS NC 8 8 CS NC 9 9 NC Ground shielded wires either at the CIDRW Controller side or at the PC/AT side. CIDRW System User’s Manual SECTION 2 Connections and Wiring CIDRW Controller V700-L22 D-SUB, 9-pin Socket type #4-40 33 SECTION 2 Installation and Connections/Wiring Amplifier Unit ■ Connector for connecting a CIDRW Head 1. Align the pin on the connector with the channel in the cable connector and insert SECTION 2 ...

https://www.fa.omron.co.jp/data_pdf/mnu/z167-e1-06a_v640-ham11-v2_hs61_v700-l22_11.pdf

マニュアル
PDF[Z197-E1-04] ZX-L-N Series Smart Sensors (Laser Ty...
...3 SD 3 SD 4 N.C. 4 ER 5 SG 5 SG 6 N.C. 6 DR 7 N.C. 7 RS 8 N.C. 8 CS 9 N.C. 9 CI Connector hood FG * Pin Nos. may vary with the type and model of the external device to be connected.For details, refer to the instruction manual of your programmable controller or personal computer. ZX-L-N User’s Manual Section 7 APPENDIX Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p) 10% max. Supplied from Amplifier Unit Current consumption Power supply voltage: 12 V, Current ...

https://www.fa.omron.co.jp/data_pdf/mnu/z197-e1-04_zx-l-n.pdf

マニュアル
PDF[Z208-E1-04] ZS-L Series (Ver 2.0) Smart Sensor (2...
...Signal Name NC Pin No. 1 Pin No. 1 Signal Name NC SD(TXD) 2 2 RD(RXD) RD(RXD) 3 3 SD(TXD) RS(RTS) 4 4 NC CS(CTS) 5 5 SG(GND) NC 6 6 NC NC 7 7 RS(RTS) NC 8 8 CS(CTS) SG(GND) NC 9 9 NC 6 7 8 9 10 ZS-L User’s Manual 4-11 Section 4 RS-232C Input/Output Setting the Communication Specifications Set the RS-232C communications specifications. Match the communication specifications of the ZS-L Series to those of the external device. FUN mode-[...

https://www.fa.omron.co.jp/data_pdf/mnu/z208-e1-04_zs-l.pdf

マニュアル
PDF[Z209-E1-03] ZS-MDC (Ver 2.0) Smart Sensor (Multi-...
...1 Section 5 APPENDIX 6 7 NC Pin No. 1 Pin No. 1 Signal Name NC SD(TXD) 2 2 RD(RXD) 3 3 SD(TXD) 4 4 NC CS(CTS) 5 5 SG(GND) NC 6 6 NC NC 7 7 RS(RTS) NC 8 8 CS(CTS) 9 9 NC Signal Name RD(RXD) RS(RTS) SG(GND) NC 10 Item 5-10 8 9 ZS-XRS2 Applicable controller ZS Series Ambient temperature Operating: 0 to 50°C, Storage: -15 to +60°C (with no icing or condensation) Ambient humidity Operating and storage: 35% to 85% RH (with ...

https://www.fa.omron.co.jp/data_pdf/mnu/z209-e1-03_zs-mdc.pdf

マニュアル
PDF[Z210-E1-04] ZS-DSU (Ver 2.0) Smart Sensor (Data S...
...Signal name 4-4 ZS-DSU User’s Manual 8 9 Signal name NC SD(TXD) 2 2 RD(RXD) RD(RXD) 3 3 SD(TXD) RS(RTS) 4 4 NC CS(CTS) 5 5 SG(GND) NC 6 6 NC NC 7 7 RS(RTS) NC 8 8 CS(CTS) SG(GND) NC 9 9 NC 10 Section 4 RS-232C Input/Output Setting the Communication Specifications Set the RS-232C communications specifications. Match the communication specifications of the ZS-DSU to those of the external device. FUN Mode-[SYSTEM]-[COM] Setting RS232C Range LENGTH 8BIT, 7BIT (default value: ...

https://www.fa.omron.co.jp/data_pdf/mnu/z210-e1-04_zs-dsu.pdf

マニュアル
PDF[Z218-E1-01A] V640-HAM12/HS62, V700-L11/L22 *V640-...
...2 RD SD 3 3 SD NC 4 4 NC SG 5 5 SG NC 6 6 NC RS 7 7 RS NC 8 8 CS NC 9 9 NC Ground shielded wires either at the CIDRW Controller side or at the PC/AT side. CIDRW System User’s Manual SECTION 2 Connections and Wiring CIDRW Controller V700-L22 D-SUB, 9-pin Socket type #4-40 29 SECTION 2 Installation and Connections/Wiring Amplifier Unit ■ Connector for connecting a CIDRW Head 1. Align the pin on the connector with the Connections and Wiring SECTION 2 channel in the cable ...

https://www.fa.omron.co.jp/data_pdf/mnu/z218-e1-01a_v640-ham12_hs62.pdf

マニュアル
PDF[Z236-E1-08] ZS-HL Series Smart Sensor (2D CMOS La...
...Controller side 3 7 4 8 5 9 Signal name NC SD(TXD) 2 2 SD(TXD) RD(RXD) 3 3 RD(RXD) RS(RTS) 4 4 RS(RTS) CS(CTS) 5 5 CS(CTS) NC 6 6 NC NC 7 7 NC NC 8 8 NC SG(GND) NC FG 9 9 SG(GND) 10 Shell Shell FG Note 1: Plug type connector ZS-HL User’s Manual 7-5 Section7 Connecting Using a RS-232C Cable  RS-232C Cable for Connecting to a Personal Computer • ZS-XRS2 (cable length: 2 m) Controller side Personal computer side (PC/...

https://www.fa.omron.co.jp/data_pdf/mnu/z236-e1-08_zs-hl.pdf

マニュアル
PDF[Z237-E1-03] ZJ-SD Series Smart Electrostatic Sens...
...3 SD 3 SD 4 N.C. 4 ER 5 SG 5 SG 6 N.C. 6 DR 7 N.C. 7 RS 8 N.C. 8 CS 9 N.C. 9 Connector hood CI FG * Pin No. may vary with the type and model of the external device to be connected. For details, refer to the instruction manual of your programmable controller or personal computer. 122 ZJ-SD User’s Manual Section 7 Specifications and Dimensions Item ZJ-SF11 Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p) 10% max. Supplied from Amplifier Unit Current consumption At ...

https://www.fa.omron.co.jp/data_pdf/mnu/z237-e1-03_zj-sd.pdf

マニュアル
PDF[Z241-E1-03] S8M Digital Multicircuit Protector Us...
...Example 1:1 Connection Using the RS-232C Port ■ Connection to a Windows Computer Windows computer S8M Pin Name Name Pin 1 CD 2 RD 3 SD RS4 ER 232C 5 SG inter6 DR face 7 RS 8 CS 9 CI D-Sub 9-pin (female) RS-232C SD 1 terminals RD 2 SG 3 D-Sub 9-pin (male) Example 1:1 Connection Using K3SC Serial Adapters The K3SC Serial Adapters are required when the distance is over 15 m. Computer RS232C interface CD RD SD ER SG DR RS ...

https://www.fa.omron.co.jp/data_pdf/mnu/z241-e1-03_s8m.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。