ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 2913 件が検索されました。(1741 - 1760件を表示)
マニュアル
PDF[Z288-E1-05] ZG2 Series Smart Sensor (2D Profile M...
... layout. ZS-XRS2 (cable length: 2 m) 4 10 Fitting section 1 Personal computer side (PC/AT compatible) (Note 1) 5 4 3 2 1 9 Signal name NC SD (TXD) RD (RXD) RS (RTS) CS (CTS) NC NC NC SG (GND) NC FG Pin No. 1 2 3 4 5 6 7 8 9 10 Shell 8 7 6 Pin No. 1 2 3 4 5 6 7 8 9 Signal name NC RD (RXD) SD (TXD) NC SG (GND) NC RS (RTS) ...

https://www.fa.omron.co.jp/data_pdf/mnu/z288-e1-05_zg2.pdf

マニュアル
PDF[Z307-E1-02] V640-HAM11-V3/HAM11-L/HS61/HS62, V700...
...2 RD SD 3 3 SD NC 4 4 NC SG 5 5 SG NC 6 6 NC RS 7 7 RS NC 8 8 CS NC 9 9 NC Ground shielded wires either at the CIDRW Controller side or at the PC/AT side. CIDRW System User’s Manual SECTION 2 Connections and Wiring CIDRW Controller V700-L22 D-SUB, 9-pin Socket type #4-40 39 SECTION 2 Installation and Connections/Wiring Amplifier Unit ■ Connector for Connecting a CIDRW Head 1. Align the pin on the connector with the channel in the cable connector and insert SECTION 2 ...

https://www.fa.omron.co.jp/data_pdf/mnu/z307-e1-02_v640-ham11-v3.pdf

マニュアル
PDF[Z316-E1-02] FQ-CR2 Fixed Mount 2D Code Reader Use...
... as PLCs, are connected. (Setup Mode) − [Sensor settings] − [Network] − [Ethernet] 1 2 Set [Auto] to [OFF]. Set the IP address and subnet mask according to the network where the external devices, such as PLCs, are connected. Note If you connect OMRON ...

https://www.fa.omron.co.jp/data_pdf/mnu/z316-e1-02_fq-cr.pdf

マニュアル
PDF[Z329-E1-02] FQ-CR1[][][][][]-M Fixed Mount Multi ...
...2 Installation and Connections (Setup Mode) − [Sensor settings] − [Network] − [Ethernet] 1 2 Set [Auto] to [OFF]. Set the IP address and subnet mask according to the network where the external devices, such as PLCs, are connected. Note If you connect OMRON ...

https://www.fa.omron.co.jp/data_pdf/mnu/z329-e1-02_fq-cr1_____-m.pdf

マニュアル
PDF[Z333-E1-04] V400-R2 Series Ultra Small Multi-code...
...Wire color Pin No. Signal name Function Reader Green 1 SD Transmission data White 2 RD Received data Gray 3 RS Transmission request Signal direction Upper equipment Blue 4 CS Transmission allowed Brown 5 TRIG External trigger signal - 6 NC Not connected Black 7 S.GND 0V Red 8 VCC Power supply External External Yellow - (Note) OK READ OK output External Orange - (Note) NG READ NG output External When you make a connection cable, use the following connectors. Recommended parts for the connector Usage Manufacturer Model For cable relay Hosiden Corporation TCS8587-0170477 For panel installation Hosiden Corporation TCS1080-0120177...

https://www.fa.omron.co.jp/data_pdf/mnu/z333-e1-04_v400-r2.pdf

マニュアル
PDF[Z334-E1-03] V500-R2 Series Fixed Laser-Type Barco...
...Made by Hosiden Corporation TCP1394-715267 (TypeA) Wire color Pin No. Signal name Function Green 1 SD Transmission data White 2 RD Received data Gray 3 RS Transmission request Blue 4 CS Transmission allowed Brown 5 TRIG External trigger signal - 6 NC Not connected Black 7 S.GND 0V Reader Signal direction Upper equipment External Red 8 VCC Power supply External Yellow - (Note) OK READ OK output External Orange - (Note) NG READ NG output External Connection with upper equipment p.98, p.99 The OK and NG output lines are not connected to the DIN 8-pin connector. To use ...

https://www.fa.omron.co.jp/data_pdf/mnu/z334-e1-03_v500-r2.pdf

マニュアル
PDFRFID System V680S Series Reader/Writer
...(i.e., tags, tag sets, and connection settings). Refer to the following manuals for details on the tag data link settings that are made with the Network Configurator. • NJ-series CPU Unit Built-in EtherNet/IP Port User´s Manual (Cat. No. W506) • ...

https://www.fa.omron.co.jp/data_pdf/mnu/z353-e1-16_v680s-hmd6_-eip.pdf

マニュアル
PDF[Z360-E1-05] V640-HAM11-V4/L-V2/HS61/HS62, V700-L1...
...Output 4 — — Output 5 Signal ground SG — 6 — — Input Use in the open status. 7 Request send RS Output Always ON during normal operation 8 Clear to send CS Input Operates even if not connected. 9 — NC — Not connected Always OFF Recommended Models Manufacturer Cable*1 Connector Socket Hood Model Hitachi Cable CO-MA-VV-SB 5PX28AWG OMRON XM2D-0901 XM2S-0913 *1: The bending radius of the recommended RS-232C cable is 44 mm. 36 CIDRW System User’s Manual SECTION 2 Installation and Connections/Wiring • Wiring The cable length should be no greater than 15 m. PC/AT ...

https://www.fa.omron.co.jp/data_pdf/mnu/z360-e1-05_v640-ham11-v4_-l-v2.pdf

マニュアル
PDF[Z362-E1-09] ZW-8000[]/7000[]/5000[] Confocal Fibe...
...System setting [SYSTEM] Communications [COM] RS-232C [RS232C] Ethernet [ETN] Delimiter [DELIMI] Pages Data length 7bit [7BIT]/8bit [8BIT]* [DATA] Parity [PARITY] Stop bit [STOP] Baud rate [BAUD.RT] CS/RS [...

https://www.fa.omron.co.jp/data_pdf/mnu/z362-e1-09_zw-_000.pdf

マニュアル
PDF[Z363-E1-07] ZW-8000[]/7000[]/5000[] Confocal Fibe...
... links (i.e., tags, tag sets, and connection settings). Refer to the following manuals for details on the tag data link settings that are made with the Network Configurator. • NJ-series CPU Unit Built-in EtherNet/IP Port User’s Manual (Cat. No. W506) • ...

https://www.fa.omron.co.jp/data_pdf/mnu/z363-e1-07_zw-_000.pdf

マニュアル
PDFVision Sensor FH Series Vision System
... Serial Interface 1 Wiring Sensor controller Signal name Pin No. RD 2 SD 3 GND 5 External device to be connected Pin No. Signal name * RD * SD GND * RS/CS control cannot be used Use a shielded cable. FH Series Vision System Hardware Setup Manual (Z366-E1) 6-45 6 6-5-1 All Series • Bundle each cable with SG (signal ground) as a twisted pair cable. Connect the bundled SG cables with the connector on the sensor controller and the connector on the other device. • Connect the communication cable shield to the RS-232C connector shell on the ...

https://www.fa.omron.co.jp/data_pdf/mnu/z366-e1-28_fh.pdf

マニュアル
PDFVision Sensor FH Series Vision System
... string "n1,n2". The setting is same as the data value of errorKind00000. Refer to data of errorKind00000. ioIdent2 Serial (Ethernet) UdpNormal: Normal (UDP) TcpNormal: Normal (TCP) TcpClient: Normal (TCP Client) UdpNormal2: Normal (UDP) (Fxxx series method) UdpPlcLink: PLC Link (SYSMAC ...

https://www.fa.omron.co.jp/data_pdf/mnu/z367-e1-15_fh.pdf

マニュアル
PDF[Z396-E1-03] NX-CSG[][][] Communication Control Un...
... Communications 8-1 8-1-1 Overview of the CIP Message Communications Service Overview of the CIP Message Communications Service The CIP Safety-compliant Communication Control Unit has the CIP message communications server capabilities. You can use the CIP message communications clients on ...

https://www.fa.omron.co.jp/data_pdf/mnu/z396-e1-03_nx-csg.pdf

マニュアル
PDFUHF RFID System V780-series Reader/Writer
...-1 7 7 Ethernet/IP Communications 7-1 Outline 7-1-1 EtherNet/IP Communications Protocol Data is exchanged cyclically between Ethernet devices on the EtherNet/IP network using tag data links as shown below. An example of connection with a ...

https://www.fa.omron.co.jp/data_pdf/mnu/z402-e1-11_v780-hmd68-e__-__.pdf

マニュアル
PDF[Z407-E1-06] MicroHAWK V320-F/V330-F/V420-F/V430-F...
... is not necessary to connect with a PC during operation. Additional Information The cable to use for Serial (RS-232C) communication is RS-232C-I/O Y cable (V430WQR-3M). Please use this cable when connecting to a PC by RS-232C. When connecting with OMRON ...

https://www.fa.omron.co.jp/data_pdf/mnu/z407-e1-06_v3_0-f_v4_0-f.pdf

マニュアル
PDFVision Sensor FHV Series Smart Camera
...RS-232C IN RS-232C OUT RS-232C 0V Color Violet Green Pale blue Stripe Yes Yes Yes External device to connect Pin No. Signal name * RD * SD * GND RS/CS control is not allowed. Use a shielded cable. 6-18 FHV Series Smart Camera Setup Manual (Z408-E1) 6 Power Supply and I/O Interface 6-5 Ethernet Interface The Ethernet port on the Smart Camera can be used for EtherNet/IP or Serial (Ethernet) communication. Precautions for Safe Use • Use only the cables designed specifically for the product. Use of other cables may result in malfunction or damage ...

https://www.fa.omron.co.jp/data_pdf/mnu/z408-e1-11_fhv7h.pdf

マニュアル
PDF[Z414-E1-01] V320-F/V420-F/V430-F Series Auto Focu...
...2.1.0 Ver. 4.□□ Ver. 9.66 Ver. 1.993 Ver. 1.00 Ver. 1.00 RJ50 to RS-232 and external power supply, straight OMRON OMRON Programmable Controller V430-WPLC-2M*1 (CS/CJ/NJ) RS-232C cable 97-900006-01 OMRON Power supply AC power supply *1. Refer to 6.2. Cable Wiring Diagram for how to prepare the RS-232C cable yourself. 6 5. Applicable Devices and Support Tools WebLink cannot be used for RS-232C connection. To use WebLink, the following system components for USB connection are required. PC (OS: Windows 10) V320-F000M12M-SRX...

https://www.fa.omron.co.jp/data_pdf/mnu/z414-e1-01_v320-f_v420-f_v430-f.pdf

マニュアル
PDFFiber Laser Marker MX-Z2000H-V1 series
...RD (RXD) 1 SD (TXD) 3 3 SD (TXD) SG (GND) 7 4 ER (DTR) 1 D-sub, 15-pin 5 SG (GND) 6 DR (DSR) 7 RS (RTS) 8 CS (CTS) D-sub, 15-pin D-sub, 9-pin Serial Communications Connector hood Hardware Specifications Connector hood 1 Precautions for Correct Use Do not connect anything to those pins other than the pins No. 2, 3 or 7 on the controller side.  RS-422A interface Cable wiring diagram Controller side Data received Data sent 1 External device side SDB RDB (+) 9 − SDB SDA RDA (−) 10 − SDA RDB RDA (+)...

https://www.fa.omron.co.jp/data_pdf/mnu/z415-e1-10_mx-z2000h-v1.pdf

マニュアル
PDFFiber Laser Marker MX-Z2000H-V1 series
...) 2 2 RD (RXD) SD (TXD) 3 3 SD (TXD) SG (GND) 7 4 ER (DTR) D-sub, 15-pin 5 SG (GND) 6 DR (DSR) 7 RS (RTS) 8 CS (CTS) Connector hood Connector hood D-sub, 15-pin D-sub, 9-pin Precautions for Correct Use Do not connect anything to those pins other than the pins No. 2, 3 or 7 on the controller side. Fiber Laser Marker MX-Z2000H-V1 series User’s Manual (Z416) 8-5 8 Operation and Control by Serial Communication  RS-422A interface Cable wiring diagram Controller side Data received...

https://www.fa.omron.co.jp/data_pdf/mnu/z416-e1-10_mx-z2000h-v1.pdf

マニュアル
PDF[Z430-E1-01] V320-F/V420-F/V430-F-series Auto Focu...
....00 Ver. 1.00 --V320-F000M12M-SRX V320-WRX-2M Ver. 2.1.0 V/F320-F adapter for all V420-F cable accessories, RJ50 to DB-15 V430-WPLC-2M*1 OMRON OMRON Programmable Controller (CS/CJ/NJ) RS-232C cable 97-900006-01 OMRON Power supply AC power supply *1. Refer to 6.2. Cable Wiring Diagram for how to prepare the RS-232C cable yourself. 6 5. Applicable Products and Support Tools WebLink cannot be used for RS-232C connection. To use WebLink, the following system components for USB connection are required. PC (OS: ...

https://www.fa.omron.co.jp/data_pdf/mnu/z430-e1-01_v320-f_v420-f_v430-f.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。