マニュアル
PDF[3616492-6A] H5CC デジタルタイマ 取扱説明書(日/英語)
...[3616492-6A] H5CC デジタルタイマ 取扱説明書(日/英語) Precautions for Safe Use 1) When mounting the Timer to a panel, tighten the two mounting screws alternately, a little at a time, so as to keep them at an equal tightness. If the panel screws are tightened unequally, water may enter the panel. indicator LEDs, LCD, and resin parts may deteriorate more quickly depending on the application environment, preventing normal indications. Periodic inspection and replacement are required. 21) The waterproof packing may deteriorate, shrink, or harden depending on the application...

https://www.fa.omron.co.jp/data_pdf/mnu/h5cc_inst-3616492-6a.pdf

マニュアル
PDF[1148541-8C] H5CX-A□-N/L□-N デジタルタイマ 取扱説明書 (日/英語)
...Key-protect switch 1 7 6 Terminals 1 and 6 of the H5CX-AD-N are connected internally. 1850 s ON Set value Basic settings can be done only with the DIP switch. Note: H5CX-L8@ has no DIP switch, so go to Step3 . Step2 on2a 12.34 0V DIP switch monitor 1off Function setting mode Instantaneous/ time-limit --sl-h Set value upper limit 1 to 9999 kp-1, kp-2, kp-3, kp-4, --kypt Key protect level kp-5, kp-6, kp-7 *2 • Models Other Than H5CX-L8E@ on-a Output ON count 0 to 9999...

https://www.fa.omron.co.jp/data_pdf/mnu/h5cx-a_-n_-l_-n_inst-1148541-8c.pdf

マニュアル
PDF[1148308-3B] H5CX-B□-N デジタルタイマ 取扱説明書 (日/英語)
..., is likely to result in minor or moderate injury or in property damage. CAUTION Digital Timer EN CAUTION INSTRUCTION MANUAL Do not allow pieces of metal, wire clippings, or fine metallic shavings or fillings from installation to enter the product. Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/h5cx-b_-n_inst-1148308-3b.pdf

マニュアル
PDF[1617398-8D] H5F Digital Daily Time Switch Instruc...
...CAUTION result property damage,or faulty operation. ● Graphic symbol ●Warning against electric shocks Notification of possible electric shocks under certain conditions. ●General warning Notification of general, unspecified prohibition items. ●Prohibition against disassembly Notification of disassembly of products, when doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/h5f_inst-1617398-8d.pdf

マニュアル
PDF[9966572-0C] H5S Digital Time Switch Instruction S...
...CAUTION could injury, property damage, or faulty operation. -1- Graphic symbol Warning against electric shock Notification of possible electric shock under certain conditions. General warning Notification of general, unspecified prohibition items. Prohibition against disassembly Notification of disassembly of products, when doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/h5s_inst-9966572-0c.pdf

マニュアル
PDF[1651863-2A] H7BX 電子カウンタ 取扱説明書 (日/英語)
... supply as the AC power supply for the Counter. Using an inverter output with an output frequency of 50/60 Hz as the power supply may cause the Counter to produce smoke or become damaged by burning. • Use a switch, relay, or other device with contacts ...

https://www.fa.omron.co.jp/data_pdf/mnu/h7bx_inst-1651863-2a.pdf

マニュアル
PDFConformance to EN/IEC Standards Front Panel Nomenc...
... supply as the AC power supply for the Counter. Using an inverter output with an output frequency of 50/60 Hz as the power supply may cause the Counter to produce smoke or become damaged by burning. • Use a switch, relay, or other device with contacts ...

https://www.fa.omron.co.jp/data_pdf/mnu/h7bx_inst-1651863-2a_en.pdf

マニュアル
PDF[5639664-5C] H7CC-A□ 電子カウンタ 取扱説明書(日/英語)
...[5639664-5C] H7CC-A□ 電子カウンタ 取扱説明書(日/英語) Precautions for Safe Use Precautions for Correct Use 1) When mounting the Counter to a panel, tighten the two mounting screws alternately, a little at a time, ...

https://www.fa.omron.co.jp/data_pdf/mnu/h7cc-a__inst-5639664-5c.pdf

マニュアル
PDF[5639665-3D] H7CC-R□ 電子タコメータ 取扱説明書(日/英語)
...(48) P3GA-11 (order separately) Back-connecting Socket 48 7.5 89.9 Panel-cutout Dimensions Diagram (Unit: mm) Panel cutouts are as shown below. (according to DIN43700) To allow easier operation, it is recommended that Adapters be mounted ...

https://www.fa.omron.co.jp/data_pdf/mnu/h7cc-r_inst-5639665-3d.pdf

マニュアル
PDF[I524-E1-04] FND-X[]/X[]-SRT Position Drivers User...
... dangers of high-voltage equipment. S Precautions on touching the terminals of the product even after power has been turned OFF. (These terminals are live even with the power turned OFF.) 5. Do not perform withstand voltage or other megameter tests on the product. Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/i524-04_fnd-x__x_-srt.pdf

マニュアル
PDF[I538-E1-01] R88A-NCW152-DRT DeviceNet Option Unit...
... AC Servomotors described in this manual are defined as looking at the end of the output shaft of the motor as follows: counterclockwise rotation is positive and clockwise rotation is negative. 7. Do not perform withstand-voltage or other megameter tests on the product. Doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/i538-e1-01_r88a-ncw152-drt.pdf

マニュアル
PDF[I561-E1-08] R88M-G[], R7D-BP[] Servomotors/Servo ...
... in place as specified before using the product.  Consult your OMRON representative when using the product after a long period of storage. WARNING Always connect the frame ground terminals of the Servo Drive and the Servomotor to 100  or less. Not doing ...

https://www.fa.omron.co.jp/data_pdf/mnu/i561-e1-08_r88m-g_r7d-bp.pdf

マニュアル
PDF[I571-E1-08] R88M-K[], R88D-KT[] AC Servomotors/Se...
... manual contains information you need to know to correctly use the Servo Drive and peripheral equipment. Before using the Servo Drive, read this manual and gain a full understanding of the information provided herein. After you finished reading the manual, keep it in a convenient place ...

https://www.fa.omron.co.jp/data_pdf/mnu/i571-e1-08_r88m-k_r88d-kt.pdf

マニュアル
PDF[I572-E1-04] R88M-K[], R88D-KN[]-ML2 AC Servomotor...
... you need to know to correctly use the OMNUC G5 Series and peripheral equipment. Before using the OMNUC G5 Series, read through this manual and gain a full understanding of the information provided herein. After you finished reading the manual, keep it in a convenient place ...

https://www.fa.omron.co.jp/data_pdf/mnu/i572-e1-04_r88m-k__r88d-kn_-ml2.pdf

マニュアル
PDFInverter MX2/RX Series EtherCAT® Communication Uni...
... protection Install the latest commercial-quality antivirus software on the computer connected to the control system and maintain to keep the software up-to-date. Security measures to prevent unauthorized access Take the following measures to prevent unauthorized access to our products. • Install physical controls ...

https://www.fa.omron.co.jp/data_pdf/mnu/i574-e1-06_3g3ax-mx2-ect_rx-ect.pdf

マニュアル
PDFInverter MX2/RX Series DriveProgramming
... systems and facilities. Notice This manual contains information you need to know to use the DriveProgramming. Before using this product, read this manual and gain a full understanding of the information provided herein. After you finished reading this manual, keep it in a convenient place ...

https://www.fa.omron.co.jp/data_pdf/mnu/i580-e1-04_3g3mx2-v1_3g3mx2-v2_3g3rx-v1_cx-drive.pdf

マニュアル
PDF[I582-E1-04] 3G3AX-MX2-CRT-E/RX-CRT-E CompoNet Com...
... correctly use the CompoNet Communications Unit (Model: 3G3AX-MX2-CRT-E/3G3AX-RX-CRT-E). Before using the CompoNet Communications Unit, read this manual and gain a full understanding of the information provided herein. After you finished reading this manual, keep it in a convenient place ...

https://www.fa.omron.co.jp/data_pdf/mnu/i582-e1-04_3g3ax-_x(2)-crt-e.pdf

マニュアル
PDF[I593-E-05] eCobra 600, 800 and 800 Inverted Robot...
... there are differences, such as in dimensions and work envelopes, the different models will be covered separately. Figure 1-1. eCobra 800 Robot By adding a SmartController EX or a PLC, the eCobra series robots replace the previous sCobra and Cobra ePLC series robots, ...

https://www.fa.omron.co.jp/data_pdf/mnu/i593-e-05_ecobra__00.pdf

マニュアル
PDF[I596-E-08] Hornet 565 Robot User's Guide
... to the robot and its power supply must be locked out and tagged out before any maintenance is performed. 14608-000 Rev. L Hornet 565 Robot User's Guide 21 2.3 Safety Precautions l The Hornet 565 must be well maintained, ...

https://www.fa.omron.co.jp/data_pdf/mnu/i596-e-08_hornet565.pdf

マニュアル
PDF[I597-E-05] Quattro 650H/650HS/800H/800HS User's G...
...Refer to Materials and Finishes on page 20. P31 Platform (P/N 09503-xxx) The P31 platform has a rotation range of ±46.25°. The tool flange is machined into one of the pivot links. It does not rotate in relation to the pivot link, ...

https://www.fa.omron.co.jp/data_pdf/mnu/i597-e-05_quattro_650h(s)_800h(s).pdf