全 634 件が検索されました。(101 - 120件を表示)
- マニュアル
...SP setting limit read RO 01 Manipulated variable read RS 01 Set point read RX 01 Process value read 01 Alarm value 1 write 02 Alarm value 2 write 03 Alarm value 3 write WB 01 Proportional band write WN 01 Integrated time write WV 01 Derivative time write WC 01 Cooling coefficient write WD 01 Dead band write 01 Input shift upper limit write 02 Input shift lower limit write 01 Set point write R% RI W% WI WS R/W Data Remarks Error response - None Write 4B Write None Read 4B Read 4B Read 4B Read 8B Read...
- マニュアル
... burnout set value read Read 4B RZ 01 Heater current read Rb 01 Valve opening read Read 8B 01 Alarm value 1 write 02 Alarm value 2 write 03 Alarm value 3 write WB 01 Proportional band write Write 4B WN 01 Integrated time write WV 01 Derivative time write WC 01 Cooling coefficient write WD 01 Dead band write Write 4B 01 Input shift upper limit write 02 Input shift lower limit write WS 01 Set point write Write 4B WW 01 Heater burnout set value write RI W% WI A--18 Command Content Remarks Error response During ...
- マニュアル
... burnout set value read Read 4B RZ 01 Heater current read Rb 01 Valve opening read Read 8B 01 Alarm value 1 write 02 Alarm value 2 write 03 Alarm value 3 write WB 01 Proportional band write Write 4B WN 01 Integrated time write WV 01 Derivative time write WC 01 Cooling coefficient write WD 01 Dead band write Write 4B 01 Input shift upper limit write 02 Input shift lower limit write WS 01 Set point write Write 4B WW 01 Heater burnout set value write RI W% WI A--18 Command Content Remarks Error response During ...
- マニュアル
... mode Save run/adjustment set value MW 01 Save operation/adjustment set value Write set value WS 01 Write set point W% 01 Write alarm value 1 W% 02 Write alarm value 2 WB 01 Write proportional band WN 01 Write integral time WV 01 Write derivative time WI 01 Write temperature input shift values WW 01 Write heater burnout detection RS 01 Read set point R% 01 Read alarm value 1 R% 02 Read alarm value 2 RB 01 Read proportional band RN 01 Read integral time RV 01 Read derivative time RI 01 Read input shift values...
- マニュアル
.... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Proportional Band Write: WB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Proportional Band Read: RB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Integral Time Write: WN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Integral Time Read: RN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Derivative Time Write: WV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Derivative Time Read: RV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control Period Write: WT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control Period Read: RT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output Operation (Normal/Reverse) Write: WU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output Operation (Direct/Reverse) Read: RU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm Mode Write: W# . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm Mode Read: R# . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm Temperature Write: W% . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm Temperature Read: R% . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Memory Bank Designation Write: WM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Memory Bank Designation Read: RM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hysteresis Write: WH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hysteresis Read: RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Status Read: RX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Read: RU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 4 Commands According to Application . . . . . . . . . . . . . . . 4-1 4-2 4-3 4-4 4-5 viii...
- マニュアル
.... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 3-5 Proportional Band Write: WB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 3-6 Proportional Band Read: RB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 3-7 Integral Time Write: WN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 3-8 Integral Time Read: RN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 3-9 Derivative Time Write: WV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 3-10 Derivative Time Read: RV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 3-11 Control Period Write: WT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 3-12 Control Period Read: RT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 3-13 Output Operation (Normal/Reverse) Write: WU. . . . . . . . . . . . . . . . . . . . . . . . . . 101 3-14 Output Operation (Direct/Reverse) Read: RU . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 3-15 Alarm Mode Write: W#. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 3-16 Alarm Mode Read: R#. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 3-17 Alarm Temperature Write: W%. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 3-18 Alarm ...
- マニュアル
... operation/ adjustment set value Writing set values SYSWAY Read set value and manipulated variable monitor Command WS 01 Write set point W% 01 Write alarm value 1 W% 02 Write alarm value 2 WB 01 Write proportional band WN 01 Write integral time WV 01 Write derivative time WI 01 Write temperature input shift values WW 01 Write heater burnout detection RS 01 Read set point R% 01 Write alarm value 1 R% 02 Write alarm value 2 RB 01 Read proportional band RN 01 Write integral time RV 01 Write derivative time RI 01 Write temperature input shift ...
- マニュアル
... set value Writing set values WS 01 Write set point W% 01 Write alarm value 1 W% 02 Write alarm value 2 Category SYSWAY Read set value and manipulated variable monitor Command WB 01 Write proportional band WN 01 Write integral time WV 01 Write derivative time WI 01 Write temperature input shift values WW 01 Write heater burnout detection RS 01 Read set point R% 01 Write alarm value 1 R% 02 Write alarm value 2 RB 01 Read proportional band RN 01 Write integral time RV 01 Write derivative time R/W Data length Write 4B Write...
- マニュアル
...WS 01 Write set point W% 01 Write alarm value 1 W% 02 Write alarm value 2 Category SYSWAY Read set value and manipulated variable monitor Command R/W Select communications writing WB 01 Write proportional band WN 01 Write integral time WV 01 Write derivative time WI 01 Write temperature input shift values WW 01 Write heater burnout detection RS 01 Read set point R% 01 Write alarm value 1 R% 02 Write alarm value 2 RB 01 Read proportional band RN 01 Write integral time RV 01 Write derivative time RI 01 Write temperature input shift values RW...
- マニュアル
...●申栢"onsetecto``` 曽障6臼田㎡eentac`$巳t{坊㍉a5fle竃bOfin駒竃ro1●鴇th● 99●噸$G「●;lOrdOCkw↓貌10錦1th●d861r◆dcor}巳ot ,ぷ舳6 '、0【}onol6ropor7蝿hlVh担保」b¶h●11rner 、零Wb●o¶hB■ur如c■ol‡h●1`m●r`53po山翼」一↓1w`tha C㎏●ocblhmo`"但nedWl±1soep、ヤ扇10rornleohOlOonol th鍵b●…o'Th∫n∩e'■r㎡pr個u■nTth倉¶`m嬬rf使m b嗣η日●瓦po蝋10鵬ttsectCx幻...
- マニュアル
...Model ode 30 W 50 W 100 00 W 200 00 W 400 00 W 750 50 W Diaa gram No. 1,, 1-1 Dimensions (mm) LM LL WOB* WB* LR C1 C C2 C D1 D2 D3 3 D4 D5 5 D6 6 1/5 R88M-W03030j-jG05BJ 69.5 101 28 55 60 40 80 70 56 55.5 40 --- 1/9 R88M-W03030j-jG09BJ 69.5 101 28 55 60 40 80 70 56 55.5 40 --- 1/21 R88M-W03030j-jG21BJ 69.5 101 43 55 60 40 60 70 56 55.5 40 --- 1/33...
- マニュアル
... W 1/5 R88M-W05030@-@G05BJ 1/9 R88M-W05030@-@G09BJ 1/21 R88M-W05030@-@G21BJ 1/33 1, 1-1 LM LR C1 C2 D1 D2 D3 D4 D5 D6 WB* 77 108.5 28 55 60 40 80 70 56 55.5 40 --- 77 108.5 29 60 70 40 95 80 65 64.5 50 --- 77 108.5 46 60 70 40 (92) 80 65 64.5 40 8 R88M-W05030@-@G33BJ 77 108.5 46 60 70 40 (92) 80 65 64.5 40 8 1/5 R88M-W10030@-@G05BJ 94.5 135 29 60...
- マニュアル
...) (B) 入出力信号テスト (C) 表示 BL 信号※テスト (B) (B) (C) TR 信号 テスト ※ (B) BU 信号 テスト ※ (B) WB 信号 テスト ※ (B) BS 信号 テスト ※ (B) リモート ON/OFF テスト (B) ※詳細は「7-1 入出力信号の詳細」 を参照してください。 66 S8BA-24D24D□□□LF 4-4 動作モード設定 4 動作を確...
- マニュアル
...ブルでの動作、性能は保証しません。 形式形 S8BWC02 3-34 外観 ケーブル長 2m 仕様以下の信号 • 信号出力(BL、TR、BU、WB) • リモート ON/OFF 入力 • UPS 停止信号入力(BS) NY シリーズ 産業用パネル型 PC マシンコントローラ ユーザーズマニュアル ハードウェア編 (SBCA-...
- マニュアル
...定) 0005(固定) +1 ユニットNo. (BCD2桁) 00∼31 +2 ヘッダコード (ASCII 2文字) 設定可能なヘッダコード MB,WS,W%,WW,WB,WN,WV +3 データコード (BCD2桁) 01∼02 +4 書き込みデータ (BCD4桁) 0000∼9999 データコード 送信データ データ 送信データチャネル数 (BCD4桁) ユニットNo. ヘッダ...
- マニュアル
...g I/OAÅå 256 _ SYSBUS [g I/O eÇjb g PC N jbg C^Cv õ^Cv ` C200H-RM201 ` C200H-RM001PV1 ` C200H-LK401 PC NA1 Kw 32 äA½Kw 16 ä NÂ\ t@WB_ 8 üÍ 4 oÍ ` C200H-FZ001 jbg X t[G AF2000` 2159CHj t DM À GAF \ä CPU u D20000` D21599j 11CH 10 ä iÔÚwè Å D00000 `00985 gpj ÀÂ\Èu C200H p CS V[ SYSBUS QÆ }j A Ý I/O YÝ_ [gI/O q y[W No. _K K ÇK 2-80 SBCC-535 gp¹¸ 10 ä ...
- マニュアル
...信ケーブルでの動作、性能は保証しません。 形式 S8BWC02 外観 ケーブル長 2m 仕様以下の信号 • 信号出力(BL、TR、BU、WB) • リモート ON/OFF 入力 • UPS 停止信号入力(BS) NY シリーズ IPC プログラマブル多軸コントローラ ユーザーズマニュアル (SBCE-403) 2-23 2-10-9 UPS *1....
- マニュアル
...す。 3-2 コマンド コマンド名称 動作 WM PT メモリ($W)書き込み PT メモリ$W へデータを書き込む 3-1 WB WD WH FM FB FD FH PT メモリ($B)書き込み PT メモリ($HW)書き込み PT メモリ($HB)書き込み PT メモリ($W)一括書き込み (FILL) PT メモリ($B)一括書き込み (FILL) PT ...
- マニュアル
...定) 0005(固定) +1 ユニットNo. (BCD2桁) 00∼31 +2 ヘッダコード (ASCII 2文字) 設定可能なヘッダコード MB,WS,W%,WW,WB,WN,WV +3 データコード (BCD2桁) 01∼02 +4 書き込みデータ (BCD4桁) 0000∼9999 データコード 送信データ データ 送信データチャネル数 (BCD4桁) ユニットNo. ヘッダ...
- マニュアル
...モート/ローカル MB 01 4B MA ME MW R% RB RN RV RC RD RI RL RO RS RX RW RZ Rb W% WB WN WV WC WD WI WS WW 01 01 01 01 02 03 01 01 01 01 01 01 02 01 01 01 01 01 01 01 01 02 03 01 01 01 01 01 01 02 01 01 RAM書込モードバックアップモード RAMデータ一括保存警報値1読出警報値...