ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 43753 件が検索されました。(9261 - 9280件を表示)
カタログ
PDF[-] G7VC-OC16-B7 Data Sheet
... with a tolerance of ±15% for coil resistance. 2. The operating characteristics are measured at a coil temperature of 23°C. 3. The value for the maximum voltage is the maximum value within the allowable voltage fluctuation range for the relay coil’...

https://www.fa.omron.co.jp/data_pdf/closed/cat/g7vc-oc16-b7_ds_e_1_1_csm1056314.pdf

カタログ
PDF[-] G7VC Data Sheet
... with a tolerance of ±15% for coil resistance. 2. The operating characteristics are measured at a coil temperature of 23°C. 3. The value for the maximum voltage is the maximum value within the allowable voltage fluctuation range for the relay coil’...

https://www.fa.omron.co.jp/data_pdf/closed/cat/g7vc_ds_e_1_1_csm1056313.pdf

カタログ
PDF[-] G9SA-300-SC Data Sheet
... using the F3SJ ensure that the DC power supply satisfies all the conditions below. • The voltage is within the rated power supply voltage range (24 VDC ±10%). • The power supply is connected only to the F3SJ or devices with a direct bearing on the F3SJ’...

https://www.fa.omron.co.jp/data_pdf/closed/cat/g9sa-300-sc_ds_e_3_2_csm1284.pdf

カタログ
PDF[-] G9SX-LM データシート
...間 SPD AND T41 AND T42 スイッチ OFF T41/T42 ・近接センサの応答時間(Tp) 以下の計算方法となります。 Tp = 1 / F (s) OFF ユニットB 注1. 上図の場合にユニット B の論理接続設定スイッチを“OFF”にしていると、 ユニットBは設定エラーと判断してロックアウト...

https://www.fa.omron.co.jp/data_pdf/closed/cat/g9sx-lm_ds_j_2_5.pdf

カタログ
PDF[J172-E1-03] G9SX-LM Data Sheet
... state, the following pulse signal is output continuously for output circuit diagnosis. When using these safety outputs as input signals to control devices (i.e. Programmable Controllers), consider the pulse signal shown below. Auxiliary output Approx. 100 ms ON OFF 360 µ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/g9sx-lm_j172-e1_6_2_csm1807.pdf

カタログ
PDF[J170-E1-03] G9SX-SM/LM Catalog
...-delay timer Extra waiting time Condition A tA Stops Condition B Off-delay setting T tB Unlocked T must be set as follows: T > tB > tA 2 Solution Extra waiting time is reduced by monitoring the motor's...

https://www.fa.omron.co.jp/data_pdf/closed/cat/g9sx-sm_-lm_j170-e1_6_1_csm1705.pdf

カタログ
PDF[-] GT1-CT01 Data Sheet
...12.6 37.4 4 Note: Accessory cable included. Wiring Diagrams Encoder input V0 V1 G0 G1 G External input A B V B Z NC A 24 VDC S V2 G2 External output V3 G3 IN NC V4 G4 V5 OUT1 V6 OUT2 Z 24 VDC Brown (red) Blue (black) Black (white) 24 VDC Encoder NPN output sensor (incremental, (photoelectric sensor, open-collector output) proximity sensor) Solenoid valve, etc. IN Blue (black) Internal connection G3 Brown (white) NC is an unused connection terminal with no shield. Shield (ground) the NC terminal if required. Solenoid valve, etc. Two-wire sensor (...

https://www.fa.omron.co.jp/data_pdf/closed/cat/gt1-ct01_q102-e1_19_2_csm2147.pdf

カタログ
PDF[-] GT1-CT01 データシート
...付属ケーブル付き ネットワーク仕様 配線図エンコーダ入力 V1 G0 G + B V 24VDC B Z NC A S V2 G2 Z− V3 G3 NC + − V5 OUT1 V6 OUT2 + 24VDC NPN出力センサ (光電スイッチ、 近接スイッチ) ソレノイド、 バルブなど IN 青︵黒︶ 茶︵白︶ マルチプルI/O ターミナルシリー...

https://www.fa.omron.co.jp/data_pdf/closed/cat/gt1-ct01_scej-003_19_5.pdf

カタログ
PDF[-] H2C Data Sheet
...[-] H2C Data Sheet Motor Timer H2C CSM_H2C_DS_E_2_2 DIN-sized 48 x 48 Motor Timer with Simple Operation for Switching Time Specifications • Three Motor Timers cover the wide time range of 6 s to 30 h with easy operation from the operation panel. • Five time specifications for each model with linked time display. • DIN-standard size of 48 x 48 mm. • Easily check operation with neon lamp. • Models with sockets and models with top wiring are also available. • Certified for UL and CSA safety standards. • Conforms to EN 61812-1 (except models that end with “-...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h2c_ds_csm80.pdf

カタログ
PDF[-] H2F-D Data Sheet
... to change without notice. 7 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h2f-d_ds_e_3_1_csm81.pdf

カタログ
PDF[-] H2F-WM Data Sheet
... to change without notice. 6 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h2f-wm_ds_e_2_1_csm82.pdf

カタログ
PDF[-] H3AM Data Sheet
... you have any questions or comments. Refer to Safety Precautions on page 7. Large Setting Dial and Moving Pointers Ideal for Easy Operation and Monitoring • Incorporating an easy-to-see large setting dial with moving pointers. • Wide time-setting range of 0.2 ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h3am_ds_e_3_1_csm83.pdf

カタログ
PDF[-] H3AM データシート
...(8分/サイクル) 10∼55Hz 片振幅0.5mm 3方向 各2サイクル(8分/サイクル) 300m/s2 6方向 各3回 2 2) 6方向 各3回 150m/s(前後方向は100m/s 500万回以上 (無負荷、開閉ひん度1,800回/h) 10万回以上(AC250V 5A 抵抗負荷、開閉ひん度1,800回/h) 2万時間 IP65(ただし、表...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h3am_ds_j_3_3.pdf

カタログ
PDF[-] H3M Data Sheet
... Accessories (Order Separately) Adapter Y92F-40 Specifications ■ Time Ranges Four time ranges are available for each timer by changing the time range selector switch positions to different combinations. Time range code Time range selector switch A 0.05 to 0.5 ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h3m_ds_e_2_3_csm90.pdf

カタログ
PDF[-] H4KV(2009年10月以前の旧タイプ) データシート
...タ 6.2 M4×8 ナベねじ 1.8 1 50 35.5 35.3 1.8 11.5 10 1.3 4.8 M4ばね座金 ●スペーサ形PFP-S 形式 標準価格(¥) ◎形PFP-M 77 16 12 5 CADデータ 34.8 44.3 16.5 形式 標準価格(¥) ◎形PFP-S 48 注. 上記形式をご注文の際は、10個単位でご注文ください。 上記価格...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h4kv_ds_j_2_4.pdf

カタログ
PDF[SGTA-029B] H4KV データシート
...タ 6.2 M4×8 ナベねじ 1.8 1 50 35.5 35.3 1.8 11.5 10 1.3 4.8 M4ばね座金 ●スペーサ形PFP-S 形式 標準価格(¥) ◎形PFP-M 77 16 12 5 CADデータ 34.8 44.3 16.5 形式 標準価格(¥) ◎形PFP-S 48 注. 上記形式をご注文の際は、10個単位でご注文ください。 上記価格...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h4kv_sgta-029_1_9.pdf

カタログ
PDFh5an_ds_e_5_1_csm97.pdf
... OMRON website. Ordering Information Operation system Time-limit operation, integrating operation Resetting system Power-OFF resetting (excluding -M), external resetting, manual resetting, automatic resetting No. of digits 4 digits (switch-selectable): 0.01 to 99.99 ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h5an_ds_e_5_1_csm97.pdf

カタログ
PDFh5an_ds_j_5_3.pdf
...合、右図の無接点回路をゲート、リセット入力に接続する場合は、無接点回路の電圧 (+V) は13∼30V、トランジスタのVCE (s)は3V以下(ただし、端子 9 または 10 から流出する電流は約 10mAです) で、ゲート、リセットを入力するときはON、入力しないときは...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h5an_ds_j_5_3.pdf

カタログ
PDF[-] H5BR データシート
...択・変更してご使用ください。 設定表示動作は内蔵電池により、通電・無通電に関係なく機能します。 時間レンジ - -. - - s 現在計時値 0.00s プリセット値 0.00s バッチカウント現在値 0 バッチカウント設定値 0 UP/DOWNモード UP 出力モード A : シグナル...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h5br_1.pdf

カタログ
PDFh5cn_ds_e_5_1_csm99.pdf
...h5cn_ds_e_5_1_csm99.pdf Digital Timer H5CN CSM_H5CN_DS_E_5_1 Miniature DIN-sized (48 x 48 mm) Quartz Timer with Abundant Series Versions • Series version cover a wide range of rated times; 9.999 s, 99.99 ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/h5cn_ds_e_5_1_csm99.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。