ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 2537 件が検索されました。(821 - 840件を表示)
マニュアル
PDF[V034-E1-05] NT30, NT30C Programmable Terminal Ope...
... connector on the other end (NT30/30C side) to connect the NT30/30C to a PC with a 25-pin connector. NT30/30C SW2 PRIN TER RESET Host Link Unit/CPU Unit –CONTRAST RS-2 32C RDB SD 24 VDC A 9-pin connector Host I/F connector (RS-232C 9-pin) SYSMAC C-series PC, CVM1/CV-series PC 25-pin connector RS-232C connector cable Use the following recommended cables (OMRON); Connector Specification Model Cable Length XW2Z-200S 2m XW2Z-500S 5m 25 pin to 9 pin 25-pin 9-pin Applicable Host Link Unit C500-LK203...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/v034-05_nt30_nt30c.pdf

マニュアル
PDF[W178-E1-01A] S3200 SYSMAC NET System Manual
...Transmissionspeedisseiectableupto9600baud. 19 ---------------------[End of Page 8427]--------------------- 庇伽o戒Sεr吻εU漉オ Section2Pt6 ThetWoserialportsOntherearoftheUnithavepinassignmentSaSde● scribedinthefollowingtable.●『hisinforrnationcanbeusedtobuildacabie betWeentheNetWorkServiceUnitandaserialdevicesuchasamodem. PmNo. SlgnalAbbr. SlgnalNamg SlgnalDlrgctlon Notgs 7 SG C◎mmonReturnLine Bilateral (PlnlisFG) 2 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w178-e1-01a_s3200.pdf

マニュアル
PDF[W182-E1-01A] 3G2C7-LK201-EV1/LK202-EV1 Host Link ...
...-232Cgnterface WhenusinganopticalfibercableorRS-422cable,severalHostLinkUnits canbecomectedtoonehostcomputer.WhenRS-232Ccablesareused, however,theconnectionmustbemadeonaone-to-onebasis,oraLink AdaptermustbeusedtoconverttoRS-422cableoropticalfiberoable.(See AppendixBSpecifica施ηsortheL加kAdaptermanualsfordetails).Thetable belowgivestheproperconnectionsforanRS-232Cinterface. 官Signal Symbol PinNo. FrameGround FG 1 SlgnalGround SG 7 SendData ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w182-e1-01a_3g2c7-lk201-ev1_202-ev1.pdf

マニュアル
PDF[W226-E1-07] CQM1 Programmable Controllers Operati...
... can be connected. Connector Pin Assignments Pin assignments for the RS-232C port are given in the following table. Pin 1 6 9 5 38 Abbreviation Name Direction 1 FG Field ground --- 2 SD (TXD) Send data Output 3 RD (RXD) Receive data Input 4 RS (RTS) Request to send Output 5 CS (CTS) Clear to send Input 6 --- Not used. --- 7 --- Not used. --- 8 --- Not used. --- 9 SG Signal ground --- Connector fitting FG Field ground --- Wiring and Connections Section 2-5 Connections The connections between the CQM1 and a personal computer are illustrated below as an example. CQM1...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w226-e1-07_cqm1.pdf

マニュアル
PDF[W317-E1-11] CPM1A Programmable Controllers Operat...
... I/O Unit 39 Unit Components Section 2-2 2-2-7 Communications Adapter Components CPM1-CIF01 RS-232C Adapter 1. Mode Setting Switch 3. RS-232C port RS-232C Port Pin Allocation FG 1 6 DCD SD 2 7 DSR RD 3 8 DTR RTS 4 2. Connector 1, 2, 3... 9 SG CTS 5 1. Mode Setting Switch Set this switch to “HOST” when using a Host Link system to connect to a personal computer. Set this switch to “NT” when connecting to a Programmable Terminal or PC for 1:1 PC Link. 2. Connector Connects to ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w317-e1-11_cpm1a.pdf

マニュアル
PDF[W319-E1-01] WS01-PSTF1-E Protocol Support Tool Op...
...tOve1⊂1・.\ 題F㎞!St。 P ・:一目Remote!Loca■ :一目Execute/OartC6i、/ ㌧翻Movet。 ㎞e口 :圏s。 `』‥・・ゼ\ 羅刹 .、端子拠L畦.,,,.ゴ・・*・・ }.・ TerptSrt,.'ChaCtictrocleW −L愈臨,Ad』≧.Date 》 `SD(Dt)-1 'SDΦ2)1 SDΦ3)1 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w319-e1-01_ws01-pstf1-e.pdf

マニュアル
PDF[W400-E1-01] CJ1W-CIF21 Simple Communications Unit...
... PC. Connector Pin Assignments CJ/CS/CQM1H Signal 9 SG 8 NC 7 NC 6 NC 5 CTS 4 RTS 3 RXD 2 TXD 1 NC (On Simple Communications Unit) FG Pin 1 SD Simple Comm. Unit Cable connections and Signal directions Signal Pin --- 1 2 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w400-01_cj1w-cif21.pdf

マニュアル
PDF[Z042-E1-04] E5ZD Multipoint Temperature Controlle...
...Conform to EIA RS-232C Section 2-1 E5ZD-4jjj-E/-6jjj-E Hardware • Signal connections: Signal name Symbol Direction Pin Field ground FG NA 1 Signal ground SG NA 7 Send data SD Output 2 Receive data RD Input 3 Send request RS Output 4 Send enable CS Input 5 Data set ready DR Input 6 Data terminal ready ER Output 20 As shown below 13 1 25 14 RS-232C Pin Assignments • Connection diagram: As shown below You cannot connect the host computer directly to more than one E5ZD Unit via the RS-232C connectors. Host computer RS-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z042-e1-04_e5zd.pdf

マニュアル
PDF[Z044-E1-04] V600-CA1A-V[]/CA2A-V[] Serial Interfa...
...-V is used. Signal g name Signal direction Abbr. Input Pin no. Output Safety ground or earth ground GR --- --- 1 Signal ground or common return line SG --- --- 7 Send data SD --- Required 2 Receive data RD Required --- 3 Request send RS --- Required 4 Can send CS Required --- 5 Data terminal ready ER --- Required (20) ID Controller Host computer GR FG SG SG ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z044-e1-04_v600-ca_a-v_.pdf

マニュアル
PDF[Z108-E1-02A] F350-C12E/C41E Visual Inspection Sys...
...is recommended. The pin numbers and names are as shown below. Recommended Connectors: Manufacturer Model OMRON Pin no. XM2A-2501 25 13 14 1 Symbol Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 DR (DSR) Data Settings Ready 7 SG (GND) Signal ground 20 ER (DTR) Data Terminal Ready 25 Section 2-4 Connecting Power Supply Unit I/O Terminals Use only shielded RS-232C cable. Wiring Standard 25-pin Cable Connection (F309-VR) F300-E2 9-pin Cable ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z108-02a_f350-c12e_c41e.pdf

マニュアル
PDF[Z109-E1-02A] F350 Visual Inspection System Refere...
.... ’ ======================================================= ’ Data definition ’ ======================================================= X1=256:Y1=240 ’Initial rectangle region value X2=X1+63:Y2=Y1+63 ’Rectangle region size CN=20 ’Max. No. of the same characters N=40 ’Max. No. of characters DIM ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z109-02a_f350.pdf

マニュアル
PDF[Z124-E1-01B] F150-C10E Visual Inspection System S...
...Yes Yes Yes Yes 4-2 Connector Use an appropriate 9-pin D-SUB female connector. The pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 30 Model No. Plug XM2A-0901 Hood XM2S-0911 Section 4-3 Wiring 4-3 Wiring...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z124-e1-01b_f150.pdf

マニュアル
PDF[Z130-E1-01] F400-C10E/C15E Color Vision Sensor Se...
...19 Section Wiring 4-1 4-2 Connector Use an appropriate 9-pin D-SUB female connector. The pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 4-2 Model No. Plug XM2A-0901 Hood XM2S-0911 Wiring Use only shielded RS-...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z130-e1-01_f400.pdf

マニュアル
PDF[Z132-E1-03] F150-C1[]E-2(-DRT) Vision Sensor Setu...
... settings, I/O formats, and operating procedures. 4-2 Connector Use an appropriate 9-pin D-SUB female connector. The pin numbers and names are shown below. Pin Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 32 Model No. Plug XM2A-0901 Hood XM2S-0911 Section 4-3...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z132-e1-03_f150-c1_e-2(-drt).pdf

マニュアル
PDF[Z136-E1-01] V530-R150 2-Dimensional Code Reader O...
... female connectors. The pin numbers and names are shown below. Recommended OMRON Connector Model XM2A-0901 Hood XM2S-0911 Pin 38 Model No. Plug Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Section 4-1 Specifications 4-1-2 Wiring Only use a shielded RS-232C cable. Standard Connections V530-R150 Signal External device Pin Pin Signal Shield Connections for RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z136-e1-01_v530-r150.pdf

マニュアル
PDF[Z140-E1-02] V530-R150E-2/R150EP-2 2-Dimensional C...
... female connectors. The pin numbers and names are shown below. Recommended OMRON Connector Model XM2A-0901 Hood XM2S-0911 Pin 38 Model No. Plug Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Section 4-1 Specifications 4-1-2 Wiring Only use a shielded RS-232C cable. Standard Connections V530-R150 Signal External device Pin Pin Signal Shield Connections for RS/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z140-e1-02_v530-r150e-2_-r150ep-2.pdf

マニュアル
PDF[Z141-E1-03] F150-3 Vision Sensor Manual 1: Setup ...
...:16 PM Section 4-1 Connector 4-1 Connector Use an appropriate 9-pin D-SUB female connector. The pin numbers and names are shown below. Pin 1 Signal FG (GND) Name Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground The following plug and hood are recommended and are available from OMRON. Model 36 Model No. Plug XM2A-0901 Hood XM2S-0911 Z141-E1-03.book ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z141-e1-03_f150-3.pdf

マニュアル
PDF[Z155-E1-02] V530-R150E(P)-3 2-Dimensional Code Re...
...-Sub female connectors. The pin numbers and names are shown below. Recommended OMRON Connector Model XM2A-0901 Hood XM2S-0911 Pin 48 Model No. Plug Signal Name 1 FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Signal ground Section 4-1 Specifications 4-1-2 Wiring Only use a shielded RS-232C cable. Standard Connections V530-R150 Signal External device Pin Pin Signal Shield Connections for ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z155-e1-02_v530-r150e-3_r150ep-3.pdf

マニュアル
PDFz906-e1-11_ne1a-scpu01_02.pdf
...!WARNING When constructing an intranet, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. Take adequate measures, such as restricting physical access to network devices, by means such as locking the installation area. When using a device equipped with the ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z906-e1-11_ne1a-scpu01_02.pdf

推奨代替品ガイド
PDFgscc-244a.pdf
...gscc-244a.pdf (1/3) タイマ/カウンタ 最新版推奨代替品ガイド 2014 年 3 月現在 形H8CA-SD□ (DC12~120V) 資料№ 2004 年 3 月生産終了商品 GSCC-244A 生産終了商品と推奨代替商品推奨代替商品① 推奨代替商品② タイマでご使用の場合 カウンタでご使用の場合 形式 形式 H5CX-A11D-...

https://www.fa.omron.co.jp/data_pdf/closed/substitute/gscc-244a.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。