全文検索:全 2559 件が検索されました。(781 - 800件を表示)
マニュアル
PDF[Z916-E1-04] NE0A Series Safety Network Controller...
...!WARNING When constructing an intranet, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. Take adequate measures, such as restricting physical access to network devices, by means such as locking the installation area. When using a device equipped with the ...

https://www.fa.omron.co.jp/data_pdf/mnu/z916-e1-04_ne0a.pdf

マニュアル
PDF[Z931-E1-07] NX-SL[][][][] Safety Control Unit Ins...
... United States and other countries. • EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. • Safety over EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. • ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA. • The ...

https://www.fa.omron.co.jp/data_pdf/mnu/z931-e1-07_nx-sl.pdf

マニュアル
PDF[3127638-6A] ZS-XPT3 プログラマブルコントローラ/プログラマブルターミナル接続用...
...うに大切に保管ください。 1 2 1 3 6 7 * 3 1 2 7 6 3 8 - 6 A * 安全上の要点 8 9 信号名 NC NC SD(TXD) 2 2 SD(TXD) RD(RXD) 3 3 RD(RXD) RS(RTS) 4 4 RS(RTS) CS(CTS) 5 5 CS(CTS) NC 6 6 NC NC 7 7 NC NC 8 8 NC SG(GND) NC FG 9 9 SG(GND) 10 シェル シェル 動作時:0∼+50℃、保存時:−15∼+60℃ (...

https://www.fa.omron.co.jp/data_pdf/mnu/zs-xpt3_inst-3127638-6a.pdf

マニュアル
PDF[3125907-4A] ZS-XRS3 パソコン接続用RS-232C ケーブル 取扱説明書(日/英...
...るように大切に保管ください。 10 5 4 1 3 9 8 * 3 1 2 5 9 0 7 - 4 A * NC ピン No. 1 信号名 NC SD(TXD) 2 2 RD(RXD) RD(RXD) 3 3 SD(TXD) RS(RTS) 4 4 NC CS(CTS) 5 5 SG(GND) NC 6 6 NC NC 7 7 RS(RTS) NC 8 8 CS(CTS) SG(GND) NC FG 9 10 シェル 9 NC シェル FG © OMRON Corporation 2017 All Rights Reserved. 安全上の...

https://www.fa.omron.co.jp/data_pdf/mnu/zs-xrs3_inst-3125907-4a.pdf

商品情報
E - 近接センサ - 形式名索引 | オムロン制御機器
...2 3 4 5 6 7 8 9 近接センサの商品でE を頭文字とするものは、以下の 32 商品です。 E2C, E2C-H E2CY-SD E2E E2E NEXT E2E-□-IL□ E2E2 E2EC E2EC-M / Q E2EF E2EH E2EQ E2EQ NEXT E2EQ-□-IL□ E2ER / E2ERZ E2EW E2EW-EV E2EY E2EZ E2E(小径タイプ) E2F E2FM E2FQ E2J E2K-C E2K-F E2K-L E2K-X E2KQ-X E2NC E2Q6 E2S E2V-X□ 関連情報 共通 生産終了...

https://www.fa.omron.co.jp/products/index/sensors/proximity-sensors/E.html

商品情報
レーザ変位センサ ZP-L ラインアップ | オムロン制御機器
...%含む(アンプユニットから供給) 消費電力 700mW以下(アンプユニットは含まない) 表示灯 MS(緑色/赤色)、SS(緑色/赤色)、RD(緑色)、SD(緑色) 外部入力 リクエスト入力 ON時:0V短絡または1.2V以下 OFF時:開放(漏れ電流0.1mA以下) 周囲温度範囲 動作時:-10~+50°C 保...

https://www.fa.omron.co.jp/product/promotion/laser-sensor-zpl/products/

商品情報
Z - 変位センサ/測長センサ - 形式名索引 | オムロン制御機器
...ZG2 ZP-L ZSシリーズ ZW-8000 / 7000 / 5000シリーズ ZW-SQシリーズ ZX-E ZX-GT ZX-L-N ZX-SAM11 ZX-SAM12 ZX-SAM14 ZX-SB11 ZX-SD ZX-T ZX1 ZX2 関連情報 共通 生産終了品/推奨代替品 目的・仕様別選定 カタログ/マニュアル訂正 輸出該非判定 規格認証/適合 RoHS/REACH対応 技術解説 使用上...

https://www.fa.omron.co.jp/products/index/sensors/displacement-sensors_measurement-sensors/Z.html

カタログ
PDF[SCHE-064B] レーザマーカ シリーズカタログ
...ヘルド型2次元コードリーダ 微細印字から金属深彫まで V400-H ■液晶モニタで2次元コードの位置確認可能 ■SDカードに読取りデータを保存 ■IP64の保護構造採用 ■ズーム切り替えレバーで視野変更が可能 ■4種類の読取り結果、液晶表示 選...

https://www.fa.omron.co.jp/data_pdf/closed/cat/mx-sl_sche-064b-web3.pdf

マニュアル
PDF[1618543-9D] E53-AK/EN デジタル調節計 オプションユニット 取扱説明書 (日/...
...形E53-ENO1(RS-232C) 「1 上位コンピュータ RS.232C'訂升多EsAKfEKIAN/EN '一一一「 No 11'RS-232C〕 1 FG IAK/EK AN/εN 1 、≠コ〕 2 SD 20 11 3 RD │fgI f2 iill 45 RSCS 18L-一 13 SGI] 6207 DRERSG シールド線一一一・接続形態は、11です。 tケーブル長は、合計で最大15mです。 線路長を延長する場合は、当社RS-232C...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/e53-ak_-en_inst-1618543-9d.pdf

マニュアル
PDF[2192564-5B] FZ4, FZD (Four Camera) Vision Sensor ...
... m, 5 m) Wire Color No. mark FZ-VPX (2 m, 5 m) Serial Interface •Connector •Wiring The maximum cable length is 15 m. • RS-232C Controller Pin No. Signal name 1 SDB(+) 2 SD/SDA(-) 3 RD/RDA(-) 4 RDB(+) 5 NC 6 NC 7 NC 8 NC 9 GND Function For RS-422 For RS-232C/RS-422 For RS-232C/RS-422 For RS-422 Not connected Not connected Not connected Not connected Signal ground Signal name ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/fz4series(fourcamera)_inst-2192564-5b(e).pdf

マニュアル
PDF[H076-E1-02] E5ZE Multipoint Temperature Controlle...
...Lit when the E5ZE is ready to operate. ERR: Lit when an error occurs in the E5ZE. RUN: Lit when the E5ZE is operating. AT: Lit when auto-tuning is being executed. RD: Lit when the E5ZE is receiving command data. ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/h076-e1-02_e5ze.pdf

マニュアル
PDF[H156-E1-07] E5AN, E5CN, E5EN, E5GN (Basic Type) D...
... output 1 Connected to communications or event inputs 1 and 2. 3 turns mA − DO NOT USE Analog input Communications 21 RS-232C Connected to event inputs 3 and 4. EV3 3 turns SD 11 B (+) 12 RD 12 A (−) 13 SG 13 DO NOT USE 24 21 DO NOT USE 21 B (+) 25 22 DO NOT USE 22 A (−) + Connected to transfer output. 3 turns 26 27 Transfer output − DO NOT USE DO NOT USE xvi 23 EV4 DO NOT USE RS-485 11 22 28 29 30 4 to 20 mA DC (Load: 600 Ω max.) Connected to...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/h156-e1-07_e5cn_an_en_gn.pdf

マニュアル
PDF[H158-E1-04] E5AN, E5CN, E5EN, E5GN (Basic Type) D...
... mm for the E5CN, E5AN, or E5EN, and 6 to 8 mm for the E5GN. ● E5AN/EN Host Host (IBM PC/AT or compatible) E5AN/EN RS-232C: 25-pin E5AN/EN RS-232C: 9-pin RS-232C RS-232C SD (TXD) 2 No. 11 SD RD (RXD) 2 No. 11 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/h158-e1-04_e5cn_an_en_gn.pdf

マニュアル
PDFi574-e1-06_3g3ax-mx2-ect_rx-ect.pdf
... yourself. When constructing an intranet, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. Take adequate measures, such as restricting physical access to network devices, by means such as locking the installation area. When using a device equipped with the ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i574-e1-06_3g3ax-mx2-ect_rx-ect.pdf

マニュアル
PDF[I581-E1-04] 3G3AX-MX2-DRT-E/RX-DRT-E DeviceNet Co...
.... When constructing an intranet, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. Take adequate measures, such as restricting physical access to network devices, by means such as locking the installation area. When using a device equipped with the ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i581-e1-04_3g3ax-_x(2)-drt-e.pdf

マニュアル
PDF[I582-E1-04] 3G3AX-MX2-CRT-E/RX-CRT-E CompoNet Com...
... yourself. When constructing an intranet, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. Take adequate measures, such as restricting physical access to network devices, by means such as locking the installation area. When using a device equipped with the ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i582-e1-04_3g3ax-_x(2)-crt-e.pdf

マニュアル
PDFi601-e-05_t20.pdf
... by yourself. • When constructing network infrastructure, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. • Take adequate measures, such as restricting physical access to network devices, by means such as locking the installation area. • When using devices equipped with an ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i601-e-05_t20.pdf

マニュアル
PDF[I633-E-09] Automation Control Environment (ACE) V...
... by yourself. • When constructing network infrastructure, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. • Take adequate measures, such as restricting physical access to network devices, by means such as locking the installation area. • When using devices equipped with an ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i633-e-09_ace.pdf

マニュアル
PDFi679-e-02_ace.pdf
... by yourself. • When constructing network infrastructure, communication failure may occur due to cable disconnection or the influence of unauthorized network equipment. • Take adequate measures, such as restricting physical access to network devices, by means such as locking the installation area. • When using devices equipped with an ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i679-e-02_ace.pdf

マニュアル
PDF[4355927-8A] K3NR, K3NP, K3NC デジタル回転/パルスメータ、デジタルタイ...
...差が大きくなることがありますのでご注意ください。 対象形式:形K3NCー□□□□ーL4、L5 対象形式:形K3NR/P/Cー□□□□ーFLK1 RXD(RD) TXD(SD) 1 OUT 4~20mA OUT 1~5V 14 15 16 17 18 19 20 21 22 23 24 25 2 3 4 5 6 7 8 9 10 11 12 13 SG 4355927-8A 詳細な使用方法は別冊をご覧ください。 形...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/k3nr_k3np_k3nc_inst-4355927-8a.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。