ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索
全文検索:全 43667 件が検索されました。(6721 - 6740件を表示)
カタログ
PDF[N179-E1-03] K8AK-AS Catalog
.../DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC Input type Direct input Direct input Direct input Continuous input at 120% of maximum input Approx. 0.12 Ω Direct input or commercially 1 s at 150% Approx. 0.02 Ω available CT Approx. 0.02 Ω Direct input --- OMRON CT --- OMRON CT *2 K8AK-AS3 0 to 200 A AC I3-COM 10 to 100 A AC , 20 to 200 A AC*2 Overload capacity Continuous input at 120% with an OMRON CT (K8AC-CT200L). 30 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-as_n179-e1_4_7_csm1020909.pdf

カタログ
PDF[N180-E1-04] K8AK-AW Catalog
...0.12 Ω (Load: 0.5 VA) Approx. 0.02 Ω (Load: 1.5 VA) Direct input or commercially available CT --- OMRON CT --- OMRON CT Overload capacity Continuous input at 120% of maximum input. 1 s at 150% Continuous input at 120% with an OMRON CT (K8AC-CT200L). 30 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-aw_n180-e1_4_8_csm1020910.pdf

カタログ
PDF[N188-E1-03] K8AK-LS Catalog
... II, pollution level 2 Power consumption Approved standards EN 61010-1 Operating resistance 10 k to 100 kΩ (variable) EMC EN 61326-1 Industrial electromagnetic environment Reset resistance 250 kΩ max. Response time Approx. 0.1 to 10 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-ls_n188-e1_4_9_csm1020918.pdf

カタログ
PDF[N186-E1-03] K8AK-PA Catalog
... voltage phases equals or exceeds the asymmetry operating value. Reset value setting range (HYS.) 5% of operating value (fixed) Reset method Automatic reset Asymmetry Operating time Phase sequence setting range (T) Phase loss 2 0.1 to 30 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-pa_n186-e1_3_7_csm1020916.pdf

カタログ
PDF[N183-E1-03] K8AK-PH Catalog
... same as the rated input voltage. 1 K8AK-PH Ratings and Specifications Ratings Rated input voltage Input load Operating time 2 3-phase, 200 to 480 VAC (3-wire) Approx. 4.1 VA Phase sequence 0.1 s±0.05 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-ph_n183-e1_3_6_csm1020913.pdf

カタログ
PDF[N185-E1-03] K8AK-PM Catalog
...30% to 25% of rated input voltage Undervoltage −30% to 25% of rated input voltage Note: The rated input voltage can be switched using the DIP switch. 100% operation at set value 5% of operating value (fixed) Automatic reset 0.1 to 30 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-pm_n185-e1_3_7_csm1020915.pdf

カタログ
PDF[N184-E1-03] K8AK-PW Catalog
...Note: The rated input voltage can be switched using the DIP switch. Operating value 100% operation at set value Reset value 5% of operating value (fixed) Reset method Automatic reset Operating time setting range (T) Overvoltage and undervoltage: 0.1 to 30 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-pw_n184-e1_3_8_csm1020914.pdf

カタログ
PDF[N187-E1-03] K8AK-TH Catalog
...85% to 110% of power supply voltage 5 VA max. 2 W max. (24 VDC), 4 VA max. (24 VAC) K8AK-TH11S Thermocouple: K, J, T, E; Platinum-resistance thermometer: Pt100, Pt1000 K8AK-TH12S Thermocouple: K, J, T, E, B, R, ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-th_n187-e1_4_7_csm1020917.pdf

カタログ
PDF[SGTE-640D] K8AK-TH カタログ
...AC24V 50/60Hz/DC24V 2W以下(DC24V)、4VA以下 (AC24V) 形K8AK-TH11S 熱電対 : K、J、T、E 白金測温抵抗体 : Pt100,Pt1000 形K8AK-TH12S 熱電対 : K、J、T、E、B、R、S、PLⅡ 有接点入力 ON : 1kΩ以下 OFF : 100kΩ以上 出力リレー外部入力 (ラッチリセット用) AC100∼240V 50/60Hz 定格電圧の85∼110% 1cリレー×1(AC250V 5A 抵抗負荷) 無接点...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-th_sgte-640_4_9.pdf

カタログ
PDF[N189-E1-03] K8AK-TS/PT Data Sheet
...100 to 240 VAC: 3.5 VA max. Rated input voltage 3-phase, 200 to 480 VAC (3-wire) Phase sequence on threephase voltage input Operating time Phase loss on three-phase 2 24 VAC/DC 100 to 240 VAC 0.1 s±0.05 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-ts_pt_n189-e1_3_7_csm1020919.pdf

カタログ
PDF[N181-E1-03] K8AK-VS Data Sheet
... to 600 V AC/DC Input impedance Overload capacity Approx. 120 kΩ Approx. 320 kΩ Approx. 1.6 MΩ Approx. 1.2 MΩ Approx. 1.7 MΩ Continuous input at 115% of maximum input 10 s at 125% (up to 600 VAC) Approx. 3.1 MΩ * The range is selected using connected terminals. 1 K8AK-VS Ratings Power supply voltage 2 Isolated power supply 24 VAC/DC 100 to 240 VAC Power consumption 24 VAC/DC: 2.0 VA/1.1 W max. 100 to 240 VAC: 4.6 VA max. Operating value setting range (SV) 10% to 100% ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-vs_n181-e1_2_9_csm1020911.pdf

カタログ
PDF[N182-E1-03] K8AK-VW Catalog
... to 600 V AC/DC Input impedance Overload capacity Approx. 120 kΩ Approx. 320 kΩ Approx. 1.6 MΩ Approx. 1.2 MΩ Approx. 1.7 MΩ Continuous input at 115% of maximum input. 10 s at 125% (up to 600 VAC) Approx. 3.1 MΩ * The range is selected using connected terminals. 1 K8AK-VW Ratings Power supply voltage Isolated power supply Power consumption 24 VAC/DC 100 to 240 VAC 24 VAC/DC: 2.0 VA/1.1 W max. 100 to 240 VAC: 4.6 VA max. 10% to 100% of the maximum value of the ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ak-vw_n182-e1_2_8_csm1020912.pdf

カタログ
PDF[N193-E1-02] K8DS-PA Catalog
... potential difference between the highest and lowest voltage phases equals or exceeds the asymmetry operating value. Reset value 5% of operating value (fixed) Reset method Automatic reset Operating time Asymmetry setting range Phase sequence (T) Phase loss 0.1 to 30 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ds-pa_n193-e1_2_5_csm1020923.pdf

カタログ
PDF[N190-E1-02] K8DS-PH Data Sheet
... is the same as the rated input voltage. 1 K8DS-PH Ratings and Specifications Ratings Rated input voltage Input load Operating time 3-phase, 200 to 480 VAC (3-wire) Approx. 2.7 VA Phase sequence 0.1 s±0.05 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ds-ph_n190-e1_2_4_csm1020920.pdf

カタログ
PDF[N192-E1-02] K8DS-PM Catalog
...% of rated input voltage Operating value Operates at 100% of set value. Reset value 5% of operating value (fixed) Reset method Automatic reset Overvoltage/UndervoltOperating time age setting range Phase sequence (T) Phase loss 0.1 to 30 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ds-pm_n192-e1_2_5_csm1020922.pdf

カタログ
PDF[N191-E1-02] K8DS-PU Catalog
...% to 25% of rated input voltage Operating value Operates at 100% of set value. Reset value 5% of operating value (fixed) Reset method Automatic reset Operating time Undervoltage setting range Phase sequence (T) Phase loss 0.1 to 30 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ds-pu_n191-e1_2_6_csm1020921.pdf

カタログ
PDF[N194-E1-03] K8DS-PZ Catalog
... highest and lowest voltage phases equals or exceeds the asymmetry operating value. Reset value 5% of operating value (fixed) Reset method Automatic reset Overvoltage/Undervoltage Operating time setting range Asymmetry (T) Phase sequence Phase loss 0.1 to 30 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8ds-pz_n194-e1_2_6_csm1020924.pdf

カタログ
PDF[N201-E1-02] K8DT-AS Data Sheet
... AC I2-COM 10 to 100 A AC *2 --- OMRON CT 200 A AC I3-COM 20 to 200 A AC *2 --- OMRON CT K8DT-AS3@@ Overload capacity Continuous input at 120% of maximum input. 1 s at 150% Continuous input at 120% with an OMRON CT (K8AC-CT200L). 30 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8dt-as_n201-e1_1_9_csm1050137.pdf

カタログ
PDF[N202-E1-02] K8DT-AW Data Sheet
... AC *2 --- 200 A AC I3-COM 20 to 200 A AC *2 --- Input type Overload capacity Direct input Direct input or commercially available CT OMRON CT Continuous input at 120% of maximum input. 1 s at 150% Continuous input at 120% with an OMRON CT (K8AC-CT200L). 30 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8dt-aw_n202-e1_2_2_csm1050138.pdf

カタログ
PDF[N205-E1-02] K8DT-LS Data Sheet
...-LS Data Sheet New Product Conductive Level Controller K8DT-LS Ideal for water level control. Sensitivity adjustment and timer for easy usage. • Sensitivity adjustment from 10 k to 100 kΩ. • Enables easy onsite adjustment. ON-delay timer from 0.1 to 10 ...

https://www.fa.omron.co.jp/data_pdf/cat/k8dt-ls_n205-e1_1_8_csm1050141.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。