ページ先頭

本文

本文

検索結果

本サイトの全ページから入力キーワードを含むページを検索できます。

全文検索 商品検索

検索結果を絞り込む


全文検索:全 532 件が検索されました。(461 - 480件を表示)
マニュアル
PDF[W218-E1-06] C200H-CPU21-E/CPU23-E/CPU31-E Program...
...] C200H-CPU21-E/CPU23-E/CPU31-E Programmable Controllers Installation Guide C200H Programmable Controllers Installation Guide (For CPU21-E/23-E/31-E) Revised April 2000 3232 Notification of and Request Related to Circuit Specification Changes to I/O Units for SYSMAC C200H, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w218-06_c200h-cpu21-e_23-e_31-e.pdf

マニュアル
PDF[W239-E1-02] SK20-C[]D[]-D SYSMAC mini Programmabl...
.../SK20-C1DT-D Only Item Specifications Transmission path Two-conductor cable (VCTF 0.75 x 2C is recommended) Transmission speed 187.5K bps Transmission distance Total length of 200 m Connectable PC as host CV, CVM1, C2000H, C1000H, C500, C200H, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w239-e1-02_sk20-c_d_-d.pdf

マニュアル
PDF[W302-E1-15] C200HX-CPU[][]-(Z)E, C200HG-CPU[][]-(...
... with other CPU Units. EPROM Memory Cassette With an EPROM Memory Cassette, the program is written using a PROM Writer. The ROM is mounted to the Memory Casette and then installed in the CPU Unit. I/O data cannot be stored. Model Capacity ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w302-e1-15_c200hx_hg_he_setup.pdf

マニュアル
PDF[W318-E1-05] SRM1(-V2) Master Control Units Operat...
...peripheral port. (Use Host Link mode when connecting a PT through an RS-232C Adapter.) The RS-232C port on an SRM1-C02-V2 can be used to connect directly to an IBM PC/AT or compatible computer, OMRON PT, or PC (C200HX/HG/HE, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w318-e1-05_srm1_v2.pdf

マニュアル
PDF[W324-E1-04] WS01-NCTF1-E SYSMAC-NCT Support Tool ...
... be used with the SYSMAC-NCT Support Tool. Applicable Position Control Units Corresponding PCs C200HW-NC113/213/413 C200HX/HG/HE(-Z) PCs C500-NC113/211 C-series and CV-series PCs Note The SYSMAC-NCT Support Tool cannot be used with C200H/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w324-e1-04_ws01-nctf1-e.pdf

マニュアル
PDF[W328-E1-02] 3G8F5-DRM21, 3G8E2-DRM21 ISA Board/PC...
... mounting more than one Master are the same as those for mounting just one Master. Refer to the previous parts of this section for information on settings and operations. When more than one Master Unit is mounted to a CS1 Series, C200HX/HG/HE, or ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w328-02_3g8f5_3g8e2-drm21.pdf

マニュアル
PDF[W334-E1-04] C200HW-NC113/NC213/NC413 Position Con...
... being turned OFF. As a countermeasure for such problems, external safety measures must be provided to ensure safety in the system. ! Caution xiv Tighten the screws on the terminal block on the AC Power Supply Unit to the torque specified in the C200H, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w334-e1-04_c200hw-nc.pdf

マニュアル
PDFw348-e1-08_drt1-com_gt1.pdf
... 1,024 inputs and outputs can be controlled by one Communications Unit (DRT1-COM). The number of I/O points for each node, however, depends on the Master Unit. For example, with the CV-series Master Unit (CVM1-DRM21-V1) or the C200HX/HG/HE and ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w348-e1-08_drt1-com_gt1.pdf

マニュアル
PDF[W352-E1-07] CPM2A Programmable Controllers Operat...
.... DeviceNet application allows networks to be constructed including devices from other manufacturers. 3 Section CPM2A Features and Functions Share Programming Devices 1-1 The same Programming Devices, such as Programming Consoles and Support Software, can be used for the C200H, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w352-e1-07_cpm2a.pdf

マニュアル
PDF[W365-E1-02] CQM1H-SCB41 Serial Communications Boa...
... set to be linked: LR 00 to LR 63, LR 00 to LR 31, or LR 00 to LR 15 A 1:1 Data Link communications system can be created between the CQM1H and another CQM1H, or between the CQM1H and the CQM1, C200HX/HG/ HE, ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w365-e1-02_cqm1h-scb41.pdf

マニュアル
PDFw367-e1-02_cs1w-slk11_21.pdf
... shown in the following table. Model not compatible with CX-Programmer or CX-Net C200H-SLK21 C1000H-SLK21 Note 148 Corresponding model compatible with CXProgrammer or CX-Net C200H-SLK21-V1 Notes Production stopped in 1992. ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w367-e1-02_cs1w-slk11_21.pdf

マニュアル
PDF[W371-E1-03] SYSMAC CPM2B Programmable Controller ...
... CPM2B. The PT must be connected to the RS-232C port; it cannot be connected to the Peripheral port. CPM2B OMRON PT One-to-one PLC Link A CPM2B can be linked directly to another CPM2B, CQM1, CPM1, CPM1A, CPM2A, CPM2C, SRM1(-V2), ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w371-e1-03_cpm2b.pdf

マニュアル
PDFw380-e1-10_cs1w_cj1w-drm.pdf
...DeviceNet Slaves Item Max. No. of Slave nodes per Master Max. No. of control points per Master Master CS Series CJ Series CVM1, CV Series CS Series, C200HX/HG/HE C200HS CS Series Model CS1W-DRM21(-V1) CJ1W-DRM21 CVM1-DRM21-V1 C200HW-DRM21-V1 CS1W-DRM21(-V1) CJ Series CJ1W-DRM21 CVM1, CV Series CVM1-DRM21-V1 CS Series, C200HX/HG/HE C200HW-DRM21-V1 ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w380-e1-10_cs1w_cj1w-drm.pdf

マニュアル
PDF[W454-E1-04] GRT1-DRT DeviceNet™ Communications Un...
....069 ms 0.135 ms The number of output bytes (BOUT) is 0 for Input Slaves, and the number of input bytes (BIN) is 0 for Output Slaves. Refresh Time (TRF) Note Master Units for CS, CJ, C200HX/HG/HE (-Z), and ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w454-e1-04_grt1-drt.pdf

マニュアル
PDF[Z146-E1-02] F160 Vision Sensor Communications Ref...
...0000 0000 0000 0000 +31 0000 0010 0101 0000 Second batch: Data 7 82 Section 4-4 Sample Ladder Program 4-4 Sample Ladder Program This sample program is compatible with OMRON C200H, C200HS, and CQM1 PLCs. The F160 inputs a measurement command from the PLC’s Read Area and outputs the judgement results to the PLC’s Write Area. PLC Settings The following communications conditions are set for the PLC’s host link port. This port may be in the PLC’s CPU Unit or a Host Link Unit. Refer to the PLC’s Operation Manual for details on ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z146-e1-02_f160.pdf

マニュアル
PDF[Z172-E1-02B] F160-2 Vision Sensor Communications ...
...+31 0000 0010 0101 0000 82 Z172-E1-02A.book Page 83 Friday, June 16, 2006 1:42 PM Section 4-4 Sample Ladder Program 4-4 Sample Ladder Program This sample program is compatible with OMRON C200H, C200HS, and CQM1 PLCs. The F160 inputs a measurement command from the PLC's Read Area and outputs the judgement results to the PLC's Write Area. PLC Settings The following communications conditions are set for the PLC's host link port. This port may be in the PLC's CPU Unit or a Host Link Unit. Refer to the PLC'...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z172-e1-02b_f160-2.pdf

PDF2025年5月28日施行政省令改正対応済み 該非判定見解書 [輸出貿易管理令別表第1]
...記以外のC120* C200H-AD* C200H-ATT*/ -BAT* C200H-CN*/ -COV*/ -DIN*/ -DSC*/ -K* C200H-LK* C200H-MAD* C200H-PI* C200H-PS* C200H-SU980* C200H-TC*/ -TL*/ -TV* 上記以外のC200H-* C200HE*/C200HG* C200HS-CN* 上記以外の...

https://www.fa.omron.co.jp/data_pdf/member/export/export.pdf

商品情報
ソフトウェア資産を活かす - PLCリプレースのおすすめ | オムロン制御機器
...ウェア資産を活かす 本文 CX-Programmerで簡単にプログラム変換。パソコンとの接続方法の一覧もご用意しています。 C200H、C200HS、C200HX/ HG/ HEシリーズからCS/ CJシリーズにCX-Programmerでプログラム変換すると、 基本命令はもちろん、応用命令(転送、四則演算、比較、論理...

https://www.fa.omron.co.jp/product/special/sysmac-plc-replace/software.html

サポート
PDF資料番号:ZYA03-554K(1/6) プログラマブルコントローラ(PLC)の予防保全のおすすめ
...CRT1シリーズ DRT2シリーズ(2004年 10年 10年 (40℃ 24時間運転) 6月以降発売形式) NXシリーズ(注3) 注1:C200H-CPU**およびC200HS-CPU**、は、電源を内蔵しているため、5年での電源交換修理を推奨します。 注2:リレ-接点出力タイプを除く(リレー接点タイプ出力ユニ...

https://www.fa.omron.co.jp/support/prevent/data/ZYA03-554_K.pdf

推奨代替品ガイド
PDFH-PCF光コネクタ 形S3200-COCF2511/-COCF2011/-COCH62M/-COC...
...形C1000H-SLK11 形3G8F7-SLK11 対象ユニット形式 形CV500-SNT31 形CS1W-CLK11( 生産終了商品) 形3G8F5-CLK11 形CV500-SLK11 形CV500-RM211/-RT211 形C200HW-SLK13/14 形C200HS-SNT32 形NSB52A(住友電工製PC98ボード) *1. 光コネクタ勘合部の寸法は、 生産終了商品、 推奨代替商品とも JISC5976( F07 形光コネクタ) に準拠しており、 実用上は...

https://www.fa.omron.co.jp/data_pdf/closed/2001061.pdf

本サイトの全ページから入力キーワードを含むページを検索できます。